Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.

Slides:



Advertisements
Similar presentations
Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Advertisements

Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan assisted NIKE Star 23 kW EOLO Star 23 kW.
Customer Service – International dept. STAR 24 3 E.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
GAS BURNERS R 40 GS 20.
Daikin Altherma™ Troubling Shooting
BUrners TRAining CEntre GAS BURNERS N 900 H/L N 900 H/L series.
Mini 24 Presents the new. Wall-hung boiler Self diagnostic system Electronic thermometer Furnace type: open Output power: 22,66 kW Min. 6,7 kW Stars of.
Refrigerators.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
Heating Control Devices
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
GI/EMME series TRAining CEntre Burner setting. TRAining CEntre Setting sequence: OIL PRESSURE SETTING : Pump and pressure regulator AIR QUANTITY SETTING.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
S8610U3009 Universal Electronic Ignition Modules Training Module (plus Universal Retrofit Kits Y8610U4001 and Y8610U6006)
Furnace Troubleshooting
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
BUrners TRAining CEntre GULLIVER BLU HYDRAULIC SCHEME.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
S8910U1000 Universal Electronic Ignition Modules Training Module
Engineer Presentation
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Service/Review... Rule # 1: Use the KISS Principle!
Student Handout Packet Go to page A4. Please answer the following questions using page A4.
Gas Furnace Planned Maintenance
BFP 21 L3 Oil Pump.
Settings & Adjustments. Settings & Adjustments.
OIIL BURNERS R D B series Riello Burners - TRAining CEntre.
OIL BURNERS RIELLO 2000 SERIES.
MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.
CONTROL BOX RMG
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
BURNER TRAINING CENTRE GI/EMME series. BURNER TRAINING CENTRE L1L2L M N ST3 30°ST2 0° ST1 130° MIN STAND-BY MAX OIL FM 123.
1 HVAC122 - Gas Gas Valves. 2 Solenoid Gas Valves The solenoid gas valve is the simplest of all valves. This valve has an electrical magnetic coil which.
HYDRAULICS & PNEUMATICS
BUrners TRAining CEntre GAS BURNERS GS series GS series.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
BUrners TRAining CEntre CONTROL BOX RMO BUrners TRAining CEntre PRESS SERIES ONE STAGE TWO STAGE THREE STAGE Dedicated to: RL SERIES ONE STAGE TWO.
LIGHT OIL BURNERS R 40 series.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
RL BLU BUrners TRAining CEntre. RL BLU BUrners TRAining CEntre CONTROL BOX LOA B27 FEATURES: #Electrical protection IP 40 #Electrical.
Unit 8 Gas-Burning Equipment. OBJECTIVES State the difference between a natural gas and an LP gas system. Describe several control sequences for gas heat.
BUrners TRAining CEntre GAS BURNERS N 120, 200, 400 N 120, 200, 400 series.
LCD Wiring Diagram Presentation B / B.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
EN 676 PRESENTATION.
BUrners TRAining CEntre RS 45/M-160/M BLU INTERMITTENT OPERATION MODE.
Process Safety Advisory on Boiler Incidents
Unit 13 Oil-Burning Equipment
Unit 7 Gas Heat: Natural and LP
GAS BURNERS GAS/2 series.
OIL BURNERS CONTROL BOX SERIES 599 SE Riello Burners - TRAining CEntre.
OFA200 Tim Stockwell.
GAS BURNERS R 40 GS 20 H/L.
CONTROL BOX RMG
CONTROL BOX RMO
CONTROL BOX RMO
S8910U1000 Universal Electronic Ignition Modules Training Module
STAR-DELTA RELAYS M STAR-DELTA BOX FAN 3 K3 K1 K2 N L1 L2 L
Universal Interrupted Electronic Oil Primary R7184U Training Module
BS 2-3-4/M INTERMITTENT OPERATION MODE.
Presentation transcript:

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET AND REPLACEMENT COMPLETE RANGE OF PERFORMANCES: –EN 676 –LOW NOx –ALL KIND OF GASES G20, G21, G25, LPG (by a KIT) –BOTH CONVENTIONAL FLUE (CF) & BALANCE FLUE (BF)

Burners TRAining CEntre RESIDENTIAL GAS BURNERS R D B R D B series MAIN FEATURES: AIR FLOW AIR PASSAGES DESIGNED TO OBTAIN: –SMALL DIMENSIONS, BUT HIGH PRESSURE –LOW NOISE –FINEST SETUP –EASY MATCHING WITH BOILERS –PERFECT BALANCE FLUE

Burners TRAining CEntre AIR PASSAGES DESIGNED TO OBTAIN: SMALL DIMENSIONS, BUT BIG PRESSURE COMPARISON RESIDENTIAL GAS BURNERS R D B R D B series

Burners TRAining CEntre EN R 40 GS 5 AIR PASSAGES DESIGNED TO OBTAIN: SMALL DIMENSIONS, BUT BIG PRESSURE RDB 1S

Burners TRAining CEntre AIR PASSAGES DESIGNED TO OBTAIN: LOW NOISE RESIDENTIAL GAS BURNERS R D B R D B series

Burners TRAining CEntre RESIDENTIAL GAS BURNERS R D B R D B series FINE AIR ADJUSTEMENT

Burners TRAining CEntre RESIDENTIAL GAS BURNERS R D B R D B series FINE AIR ADJUSTEMENT

Burners TRAining CEntre

RESIDENTIAL GAS BURNERS R D B R D B series

Burners TRAining CEntre RESIDENTIAL GAS BURNERS R D B R D B series MAIN COMPONENTS CONTROL BOX LMG 25.33OB27

Burners TRAining CEntre RESIDENTIAL GAS BURNERS R D B R D B series CONTROL BOX LMG25.33OB27 FEATURES: #UndervoltageAC 160 V #Electrical polarity must be respected #Flame signals:operation reliable value min 2µA at beginning max value 0.5µA #El. supply230 VAC % Hz

Burners TRAining CEntre RESIDENTIAL GAS BURNERS R D B R D B series Control program in the event of fault:  If a fault occurs, all outputs will immediately be deactivated (< 1 s)  On restoration of power, a restart will be made with the full program sequence  If the operating voltage drops below the undervoltage threshold, a restart will be made with the full program sequence  If there is a premature faulty flame signal  Lockout  If the contact of the air pressure monitor «LP» has welded in the working position, start up will be prevented and, after 65 seconds, lockout initiated  If the contact of the air pressure monitor «LP» has welded in the idle position: lockout at after 52.5 seconds  If the burner does not ignite by the end of safety time  Lockout  If flame is lost during operation:  Three repetitions Lockout:  Lockout cannot be changed and takes place 10 seconds after safety shutdown. A main voltage failure during that period of time wil lead to a restart. Resetting:  When never lockout occurs, the burner control can immediately be reset. To do this, keep the lockout reset button depressed for a minimum of 0.5 seconds and a maximum of 3 seconds!

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N N ? 8 REMOTE RESET IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT ELECTRICAL MODE OPERATION

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE 0” open the gas first...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE 0” open the gas first...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE 0” …waiting time...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …waiting time ”

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …pre-purge begins ”

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …pre-purge... …air pressure grows... …the air pressure switch moves...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …pre-purge ” …max time for the air pressure switch to move...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …pre-purge...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …pre-ignition.. min 37.5”

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …pre-ignition.. min 37.5”

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …pre-ignition.. …2”...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …ignition.. …2”...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …ignition..

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …ignition.. …the flame signal must be detected within 3”...

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT STARTING PROCEDURE …ignition..

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT OPERATION

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT BURNER OFF

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT BURNER OFF

Burners TRAining CEntre N L2 L PG M LINE F1 LOAD XP2 XP3 X2 X3 VSV1 BLUE W. BLACK BROWN RED PA 4 N N N XP1 X1 TS TL L N IGN. TRANSFORMER THERMOSTAT GAS VALVE FLAME SIGNAL REMOTE RESET AIR P.SWITCH FAN MOTOR LOCK OUT BURNER OFF

Burners TRAining CEntre Operating concept   Burner control has initiated lockout  Red fault LED on  ResetPress lockout reset button for s  Diagnosis of cause of fault– Wait > 10 s – Press lockout reset button for > 3 s – Read blink code of red fault LED  «Error code table A»  Burner control in operation  Green flame signal LED on  RestartPress lockout reset button for s  Read flame establishment time– Press lockout reset button for > 3 s – Read blink code of green flame signal  «Code table B» SELF-DIAGNOSTIC

Burners TRAining CEntre Error code table A Blink code Possible cause 2 x   No establishment of flame at the end of «TSA» – Faulty or soiled detector electrode – Faulty or soiled fuel valves – Poor adjustment of burner 3 x   Air pressure monitor does not close  – «LP» faulty – «LP» incorrectly adjusted – Fan motor does not run 4 x   Air pressure monitor does not open or extraneous light on burner startup – «LP» faulty  – «LP» incorrectly adjusted 5 x   Extraneous light during pre-purging  – Or internal device fault 7 x   Loss of flame during operation  – Poor adjustment of burner – Faulty or soiled fuel valves – Short-circuit between detector electrode and ground x  ;  Free

Burners TRAining CEntre Error code table A Blink code Possible cause 18 x  Air pressure monitor opens during pre- purging or operation – «LP» incorrectly adjusted – Four times loss of flame during operation 19 x   Faulty output contact – Wiring error – External power supply on output terminal 20 x  Internal device fault

Burners TRAining CEntre Code table B Blink code Flame establishment (limit 3 s) 1 x  0.4 s  0.4 s 2 x  0.8 s  0.8 s 7 x  2.8 s  2.8 s

Burners TRAining CEntre GAS LINE (both natural gas & LPG) VALVE GROUP MBDLE 055 D A B C 1. Microfilter 2. Inlet P1 (max 65 mbar) 3. Housing 4. Spring, gas pressure regulator 5. Diaphragms, gas pressure regulator 6. Cover (side, left) 7. Nozzle 8. Outlet P3 (3 ÷ 15 mbar) 9. Main flow restrictor 10. Start gas restrictor 11. Damper 12. Central chamber connection 13. Servopressure regulator 14. Adjustment screw - main flow 15. Reference value adjustment device - pressure regulator 16. Adjustment screw - start flow 17. Solenoid housing V1, V2 18. Electrical connection D The gas flow is released through chambers A, B, C and D of the GasMultiBloc. V1V2

Burners TRAining CEntre Performance can be adjusted Time cannot be adjusted

Burners TRAining CEntre Natural gas V gas used = V natural gas x f

Burners TRAining CEntre