Airmux-400 Version 2.3 GA.

Slides:



Advertisements
Similar presentations
©2010 This information is highly confidential and subject to Sprint policies regarding use and is the property of Sprint and/or its relevant affiliates.
Advertisements

How to Set Up, Secure and Manage A Network
Airmux-5000 General Availability Releases 3.4
Airmux Professional Service Training 2013 Slide 1 Airmux-400 General Availability Release 2.8 Presented by: Larry Jacobs Director, Account Management (201)
NetAstra 5000 Product Overview
Airmux-400 Version 2.4 General Availability January 2010
NetStream Product Family Overview
Agenda Super-Cells Multi-Cells
Altai Super WiFi Training WiFi Network Planning
TELECOM PRODUCT PRESENTATION “WIRELESS WITHOUT BOUNDARIES” RADITEK Terrestrial Networks
RADWIN 3.5/3.65GHz Product Portfolio January 2010.
Copyright © 2013 Cambium Networks, Ltd. All rights reserved. 1 Connecting the Un-Connected and Under-Connected October 2013.
Airmux-400 General Availability Release Agenda Airmux Technology Target Markets Airmux-400 Product Portfolio What’s new in ver ? Case Studies.
1 VIP Release “Anypoint”-to-Multipoint Wireless.
RADWIN 2000 Release RADWIN 2000 Portfolio  RADWIN 2000 portfolio comprises of 3 radio series:  C-Series – supporting up to 100 Mbps asymmetric.
RAD ISM 01/2011 Slide 1 Wireless Mobility System.
Airmux-200 Version GA.
RADWIN 5000 HPMP.
Stay ahead with RAD Training Presented by: Illy Sarid AIRMUX-400.
RADWIN 2000 Release 2.3 & WinLink 1000 Release 1.9 & BDU Release 6.2
Airmux 400 Version Slide 2 Airmux-400 in Brief Airmux-400 is a point-to-point radio solution for combined Ethernet and TDM traffic.
RAD’s Point-to-Multipoint Offering: Airmux-5000
Airmux-500 HPMP – 2011 Slide 1 Solution Note: Railway Crossing Accident Prevention Customer Type: Intercity train Strategic Sales Development.
Barkotel Experience, Projects & Services Introduces through Broadband Technology.
for WAN (WiMax). What is WiMax? Acronym for Worldwide Interoperability for Microwave Access It’s the IEEE standard, first introduced in 2001, for.
Broadband Fixed Wireless. 2 N+I_2k © 2000, Peter Tomsu 03_bb_fixed_wirel 1 GHz LOS Voice, Data,
1 © 2004, Cisco Systems, Inc. All rights reserved. Wireless LAN bridge.
Smart Grid Research Consortium Conference Communications: Technologies Systems Future Trends Dr Rick Russell.
Technologies for Wireless Multimedia in the XXI Century Porto Seguro, Brazil 5 June 2001 Joanne C. Wilson ArrayComm, Inc.
Wireless Broadband Networks Portfolio Overview
Comparison of Canopy 900 MHz Point to Multipoint Systems
Mobility at CERN 29/10/2013 HEPiX Fall IT/Communication Systems HEPiX Fall 2013.
Delivering Capacity, Low Latency and Low Jitter Jim Freeze, SVP Marketing & Alliances October 2007.
Gilad Peleg Director Technical Support BreezeLINK Introduction.
High Performance, Easy to Deploy Wireless. Agenda Foundry Key Differentiators Business Value Product Overview Questions.
1 P ROTEUS AMT Adaptive Modulation Transport. 2 Product Overview AMT-Series Indoor Unit Outdoor Unit L-Series Indoor Unit.
1999 Cabletron Systems. Wireless Networking RoamAbout Introduction to Wireless Networking Overview of the Wireless functionality Applications for Wireless.
Active Search / Find a Distributor PTP / PTMP Wireless Backhaul Company Search for Distributors, System Integrators and Service Providers. One Business.
BreezeCOM BreezeACCESS Presentation. 2 2 Introducing BreezeACCESS – the First Internet-age WLL.
WiMAX, meaning Worldwide Interoperability for Microwave Access Emerging technology that provides wireless transmission of data using a variety of transmission.
Airmux GA 2012 Slide 1 Airmux-5000 Version 3.3 General Availability July 2012.
One-stop shop for all wireless backhaul needs –Multiple frequency bands –Multiple configurations –Variable occupied bandwidth –Flexible user interfaces.
Airmux-200 Update for August Airmux 200 Slide 2 Agenda Symmetrical vs. Asymmetrical transmission HE HSS feature IDU-R 8 port PoE Wrap-up.
RADWIN 2000 Product Overview. RADWIN 2000 – General Overview High-Capacity Backhaul You Can Trust  Carrier-Class Point-to-Point radio for best performance.
Performing a Site Survey. Wireless Site Survey RF Frequencies (Licensed & Unlicensed) What market each RF Frequency serves? Types of Spectrum Analyzers.
Ultima 3 Product Family Presentation. Presentation Outline Product Family Overview Competitive Advantages Applications Competitive Analysis.
Airmux 400. Slide 2 Airmux-400 in Brief Airmux-400 is a point-to-point radio solution for combined Ethernet and TDM* traffic over license free frequencies.
Proprietary and Confidential © Copyright Alvarion Ltd. Optimized 4G Smart Grid Connectivity Eedo Lifshitz Director, Business Development.
Canopy® 400 Series AP and SM CAP and CSM Extend Video, Voice and Data Services into nLOS and NLOS Environments.
© WAVETEQ COMMUNICATIONS INC. Springfield, Illinois, USA October 17, 2007 October 17, 2007 Building Better Networks.
Femto Network Dr. Monir Hossen ECE, KUET Department of Electronics and Communication Engineering, KUET.
Wireless Ethernet Technologies. Wireless Ethernet Technology Industry technologies & market trends Choosing the right radio technology for the job Why.
CDMA X EV-DO by S.Vidhya. CDMA 2000 CDMA2000 (also known as C2K or IMT Multi ‑ Carrier (IMT ‑ MC)) is a family of 3G[1] mobile technology standards,
Presented by: Edgar Mendez System Engineer Specialist Airmux-400 Version 2.1 GA.
RADWIN 5000 JET Product Introduction
Canopy® 400 Series AP and SM CAP and CSM Extend Video, Voice and Data Services into nLOS and NLOS Environments.
Stay ahead with RAD Training Представление радиомодемов семейства Airmux.
WIRELESS FIRE DETECTION
Introduction to SkyPilot Networks November 2005
Airmux-400 Version 2.4.
“An Eye View On the Future Generation Of Phones”
Airmux-5000 General Availability Releases 3.4
4G-WIRELESS NETWORKS PREPARED BY: PARTH LATHIGARA(07BEC037)
WIMAX Presented By JAGADEESH.S 13X41A0546.
WIRELESS-COMMUNICATION
NetStream Diplo System Configuration
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Introduction to RADWIN 2000i
Presentation transcript:

Airmux-400 Version 2.3 GA

Airmux-400 in Brief Airmux-400 is a point-to-point radio solution for combined Ethernet and TDM traffic over license free frequencies

Agenda Target Markets & Benefits New Version 2.300 Product Elements Products Features Product Elements Typical Applications

Target Markets The Airmux-400 series is targeting the global markets of Cellular Backhaul, WiMAX and ISP Backhaul, Broadband Access and Private and Government Networks All these markets require higher bandwidth (TDM & ETH) with longer range, robustness; while keeping the best price performance

Airmux-400 – Benefits High bandwidth with longer range – 50 Mbps full duplex net throughput reaching up to 120 km Combined Native TDM & Native Ethernet services on one platform Competitive prices – higher Ethernet & TDM capacity for lower prices Applicable to nLOS, over-water deployments and high capacity over extended range with improved robustness thanks to the OFDM, MIMO and antenna polarization features. Flexible product usage (& stock reduction) of the configurable ODU Fast and easy deployments via installation and alignments tools

New Features & Products

Airmux-400 Version 2.3 New Features Hub Site Synchronization (HSS): Airmux-400 radios Airmux-200 radios Airmux-400 and Airmux-200 radios Monitored Hot Standby (1+1) – TDM services backup & Redundancy Diversity Feature Version 2.3 HSS V Monitored Hot Standby (MHS 1+1) Diversity Spectrum View

Hub Site Synchronization HSS between Airmux-400 radios Airmux-200 radios Airmux-400 and Airmux-200 radios HSS up to 16 radios in a site Fully supported by RAD Manager Supported by software upgrade to Airmux-400 install base All Airmux-400 radios in the field are HW ready for HSS

Monitored Hot Standby (MHS) 1+1 Providing redundancy and backup to TDM services Targeted for Cellular backhaul Providing protection against Equipment failure (ODU and IDU) Loss of air interface Using a primary link and a secondary link: Two Airmux-400 links A Airmux-400 link and a Airmux-200 link with new IDU-C Two Airmux-200 links with new IDU-C (single dual-pol antenna can be used)

Diversity Antenna diversity Capacity 25 Mbps MIMO Capacity 50 Mbps Antenna diversity Uses two antennas Each antenna experiences a different interference environment The system chooses the best received signal providing enhanced robustness Antenna diversity requires antenna separation, possible by two methods: Polarization Diversity - combines a pair of antennas with orthogonal polarizations Spatial Diversity - employs antennas that are physically separated from one another

Diversity – Receive Combining

Diversity Vs MIMO – When to Use? Use MIMO Mode to get the highest capacity, up to 50 Mbps full duplex Use MIMO when the air conditions are similar between the antennas Use Diversity instead of MIMO in the following cases: When the system cannot operate in MIMO Mode due to link conditions When you get higher capacity in Diversity Mode than in MIMO Mode Note that Diversity Mode requires understanding of the nature of interference and of the correct solution to deploy. Advise PS. Remember that the capacity in Diversity is ½ than that of MIMO

Spectrum View An RF survey tool Support link installation before service activation Activated by the installer Helps selecting the best channel during installation Supports quick and easy installation

Spectrum View – Display Information Spectral measurement for each of the 4 receivers that make the link Spectral power measurements in 5MHz channel granularity Current, average and maximum power per channel Channels free from radars, with radars and barred (for DFS bands) Scanned and un-scanned channels Channels selected for ACS Current operational channel Time stamp of the last spectrum scan Zoom, selective view of antennas and sites and detail level

Spectrum View – Tool Capabilities Save and restore – save the spectral information and also view retrieved spectral information from historical spectrum scans Diagnostics - the Spectrum View information is logged as part of the Diagnostics Information to improve link and system diagnostics and remote support. It can be retrieved from the RADWIN Manager menu with Help  Get Diagnostic Information Management Integration - Spectrum view information is supported in RADWIN’s MIB and can be used by external Network Management applications Designed for Unlicensed Spectrum – the spectrum measurement algorithms are designed to show accurate information while accommodating with variances in frequency, temperature and interference power and overcoming anomalies that tend to occur in high interference environments Scanning Time – ~10 seconds for an entire band scan. It is recommended to scan for a few minutes for accurate results.

New Products 4.8 GHz Radio Motivation Product description 4.8 GHz is a licensed band It is used mainly for security applications being part of the 4.4 – 4.9 GHz spectrum It is used also for broadband applications Part of NATO worldwide bands Product description Connectorized only Supported bands: 5.9 GHz Universal 5.8 GHz FCC/IC, 5.8 GHz MII China, 5.8 GHz WPC India 5.4 GHz FCC, 5.4 GHz IC, 5.4 GHz Universal 5.3 GHz FCC/IC, 5.3 GHz Universal 4.9 GHz FCC, 4.9 GHz Universal 4.8 GHz Universal (factory default) 2.4 GHz FCC/IC 4.8 GHz Universal band: 4.800 to 4.900 GHz (occupied spectrum. Center frequencies 4.810 to 4.890 GHz) Default channel 4.850 GHz Channel BW 20 MHz New External Antenna

Product Elements ODU Integrated dual polarization antenna Connectors: 2 x N type for external antennas, 1 IDU-ODU, 1 multi p-t-p synch IDUE Ethernet & TDM support 19” 1U PoE device supported Management Common NMS for Airmux-200 and Airmux-400

Typical Applications

Targeted HSS Applications Access and Corporate Connectivity Where any links originate from a common hub site With HSS by Airmux-400 such applications now support high capacity connectivity Backhaul HSS is needed in installations where a Airmux-400 link is the backhaul for many lower capacity access links The backhaul link can be synchronized to the access links to mitigate potential mutual interference Attack Plan Identify existing customers with mixed network of Airmux-200 and Airmux-400 Propose the HSS solution for mixed deployment

Targeted MHS Applications Provide high reliability high-capacity Point-to-Point links Provide redundancy and high reliability for carrier class operators Optimized for high capacity links operating in license-free bands Additional values: Each link can use a different band for maximum protection to the air interface Affordable SLA can be offered by protecting part of the Airmux-400 trunks with Airmux-200 Go To Market Present the capability to Cellular Operators

MHS Spec Supported in Airmux-400 by software upgrade to the install base TDM service cut-over from the primary to the secondary link is completely automatic, less than 50 ms Automatic restore to primary link as soon as it becomes available Supports up to 16 TDM services for Airmux-400 and 4 TDM services for Airmux-200 HSS is used between the links Install both sites with HSS cables for additional protection Ethernet services No Ethernet 1+1 Ethernet traffic is always “on” on both links, while the TDM service is running only on one link Each link carries different Ethernet traffic

Cellular Backhaul Applications Remote Site Temporary Backhaul Urban Area Deployment Rural Area Deployment Village NLOS Backhauling Central Site Intermediate Backhaul Small Town Access Service Backhaul to Low ARPU Areas Village Backup to Wired Backhaul Remote Site Remote Site

Cellular Backhaul Applications Alternative to Leased Lines Complementing existing networks in Rural Areas Remote communities & locations Low ARPU communities Hard to reach locations and NLOS scenarios Overlay to network coverage in Urban Areas Enhance coverage and capacity Providing service to “low-ARPU” locations in the city Hard to reach locations – Problematic trenching or N-LOS scenarios NLOS scenarios Addressing peak hours requirements and temporary events 3G ramp-up (More base stations; More capacity per site; Street-level locations) Intermediate backhaul Backup

Broadband Access Expand broadband data and voice to rural and underserved markets Eliminate costly rollout investments and speed time to market Telco grade – Long range; High capacity (x 10 more than leased line) Airmux-400 Access Unit Central Site Airmux-400 Remote Site Airmux-400 Remote Site Airmux-400 Remote Site Airmux-400 Remote Site Airmux-400 Remote Site