Radiation Protection in Radiotherapy Part 15 Security of sources, and disposal of disused sources IAEA Training Material on Radiation Protection in Radiotherapy.

Slides:



Advertisements
Similar presentations
Radiation Protection Legislation Stephen McCallum
Advertisements

Barhale Procedure for Site Establishment
East Carolina University Compressed Gas Safety Training Program
Radiation Protection in Radiotherapy Part 16 Discharge of Patients IAEA Training Material on Radiation Protection in Radiotherapy.
Exemption, Clearance, Discharges
HAZARD COMMUNICATIONS / E N V I R O N H & S T R A I N I N G P R O G R A M HAZARD COMMUNICATION PROGRAM OSHA Standard 29 CFR The OSHA hazard communication.
IAEA International Atomic Energy Agency Responsibility for Radiation Safety Day 8 – Lecture 4.
Categorization of Radioactive Sources
National Committee for the Certification of Radiation Protection Officer SAFETY AND WORK PROCEDURE IN SALES OF RADIOACTIVE MATERIAL AND IRRADIATING APPARATUS.
School for drafting regulations Nuclear Safety Decommissioning Vienna, 2-7 December 2012 Tea Bilic Zabric.
Radiation Protection in Radiotherapy
Gauges and well logging
Gauges and well logging
Regulatory Body MODIFIED Day 8 – Lecture 3.
Health and Safety.
Radiation Protection in Radiotherapy Part 14 Transport Safety IAEA Training Material on Radiation Protection in Radiotherapy.
Protection Against Public Exposure and
WHS Management Plans.
Protection Against Occupational Exposure
W504 - Management of asbestos containing materials.
1 - Issuing regulations Governmental, Legal and Regulatory Framework for Safety (GSR – Part 1) Requirement 1: National policy and strategy for safety The.
BRC Food Safety Quality Management System Training Guide
Hazard Communication Training Program “Right-to-Know” Program.
TEAM 1 NONAMECOUNTRY 1SU RUI (LEADER)CHINA 2TENG IYU LIN (PRESENTER)MALAYSIA 3MUHAMMAD TARIQ AZIZ (RAPPORTEUR)PAKISTAN 4NORAISHAH PUNGUTMALAYSIA 5MOHAMMAD.
IAEA International Atomic Energy Agency Reviewing Management System and the Interface with Nuclear Security (IRRS Modules 4 and 12) BASIC IRRS TRAINING.
Part 12 IAEA Training Material on Radiation Protection in Nuclear Medicine Protection of the General Public.
IAEA REGULATION RADIOACTIVE MATERIALS TRANSPORTATION IN ARMENIA Ashot Mnatsakanyan Head of Radiation Safety Department Armenian Nuclear Regulatory Authority.
ZHRC/HTI Financial Management Training Session 9: Stores and Supplies Management.
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part II.
Important informations
Prime Responsibility for Radiation Safety
RER/9/111: Establishing a Sustainable National Regulatory Infrastructure for Nuclear and Radiation Safety TCEU School of Drafting Regulations November.
MODULE “PROJECT MANAGEMENT AND CONTROL” SAFETY ASSESSMENT DURING DECOMMISSIONING SAFE DECOMMISSIONING OF NUCLEAR POWER PLANTS Project BG/04/B/F/PP ,
VIII.3. Optimization of Protection for Medical Exposures in Nuclear Medicine 1. Design considerations Postgraduate Educational Course in Radiation Protection.
Programme Performance Criteria. Regulatory Authority Objectives To identify criteria against which the status of each element of the regulatory programme.
 Radiopharmaceuticals are agents used to diagnose certain medical problems or treat certain diseases. They may be given to the patient in several different.
Main Requirements on Different Stages of the Licensing Process for New Nuclear Facilities Module 4.5/1 Design Geoff Vaughan University of Central Lancashire,
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Regulatory Authority.
IAEA International Atomic Energy Agency PGEC Part VI Planned Exposure Situations - Generic Requirements Module VI.3 Requirements for public exposure in.
NotificationNotification. Notification Objectives To understand the need for the Regulatory Authority to identify and locate radiation sources through.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part III.
AuthorizationAuthorization. Authorization Objectives To provide understanding of the authorization process and the procedures for its implementation.
Authorization Part III. Content of a license Structure of a license General elements General and specific conditions Annexes Documents attached (e.g.
Management System Part II: Inventory of Radiation Sources – Regulatory Authority Information System (RAIS)
International Atomic Energy Agency IX.4.2. Principles of radioactive waste management Basic technical management solutions: concentrate and contain, storage.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Technical Services.
Erman Taşkın. Information security aspects of business continuity management Objective: To counteract interruptions to business activities and to protect.
Part VIII:Medical Exposures in Radiotherapy Lecture 2 : Scope and Responsibilities – Training of staff IAEA Post Graduate Educational Course on Radiation.
Management and Safe Disposal of Radioactive Waste COUNTRY STATUS:ZIMBABWE By Rujeko Lynette Mpandanyama Tunis, March 2014.
Radiation Safety Regulations Part VIII: Management requirements and other requirements.
IAEA International Atomic Energy Agency Radiation protection of the public IAEA Regional Training Course on Radiation Protection of patients for Radiographers,
ISO 9001:2015 Subject: Quality Management System Clause 8 - Operation
Working Procedure with Ionizing Radiation 1. Introduction Introduction Classification of Areas Classification of Areas Safe Handling/Use of Safe Handling/Use.
Scientific data storage: How are computers involved in the following?
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Program Performance Criteria.
Meet your Regulator Workshop with FANR licensees October 2011 Dr. John Loy Director, Radiation Safety Federal Authority for Nuclear Regulation.
Technical Services. Objectives To identify the technical services needed within the infrastructure for an effective implementation of regulatory programme.
Training Module Preparation for “AERB norms, licenses and signage”
Sustaining Cradle-to-Grave Control of Radioactive Sources (INT-9182) Meeting on the development, revision and implementation of the safety case and safety.
Module Planned exposure situations Public exposure (GSR Part 3)
Sustaining Cradle-to-Grave Control of Radioactive Sources (INT-9182) Workshop on implementation of a national cradle-to-grave control system for radioactive.
REGULATORY REQUIREMENTS FOR HANDLING RADIOISOTOPE Mohd Abd Wahab Yusof (Dr) Malaysian Nuclear Agency.
RER/9/111: Establishing a Sustainable National Regulatory Infrastructure for Nuclear and Radiation Safety TCEU School of Drafting Regulations
Occupational Radiation Protection during High Exposure Operations
RPC INTERNATIONAL WORKSHOP ON NATIONAL REGISTERS OF RADIATION SOURCES AT THE IAEA’S HEADQUARTERS IN VIENNA, AUSTRIA, 20 TO 23 MARCH 2017 Rustem Paci.
Eija Venelampi Radiation and Nuclear Safety Authority – STUK, Finland
Categorization of Radioactive Sources
Safety and Security of Radiation Sources
Communication and Consultation with Interested Parties by the RB
Presentation transcript:

Radiation Protection in Radiotherapy Part 15 Security of sources, and disposal of disused sources IAEA Training Material on Radiation Protection in Radiotherapy

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources2 BSS glossary: l A source is: “Anything that may cause radiation exposure, such as by emitting ionizing radiation or releasing radioactive substances or materials. For example, materials emitting radon are sources in the environment, a sterilization gamma irradiation unit is a source for the practice of radiation preservation of food, an X ray unit may be a source for the practice of radiodiagnosis, and a nuclear power plant is a source for the practice of generating electricity by nuclear power. A complex or multiple installation situated at one location or site may, as appropriate, be considered a single source for the purposes of application of the Standards.”

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources3 Objectives l Be able to apply the concept of a radiation source to radiotherapy l Understand how sources in radiotherapy can be made secure l Be familiar with appropriate ways to dispose of sources in radiotherapy

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources4 Contents 1. Sources in radiotherapy 2. Security of sources 3. Disposal of disused sources

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources5 1. Sources in radiotherapy l X Ray equipment l Radioactive sources for external beam radiotherapy l Radioactive sources for brachytherapy l Other sources

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources6 A note on exempted sources l In general radioactive sources used in radiotherapy will NOT qualify for exemption according to BSS schedule I Radiotherapy sources are HOT!

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources7 X Ray equipment l Very common source of radiation in radiotherapy l Not of major concern for security of sources and disposal because no radiation is produced when the unit is turned off... Courtesy of Siemens Medical

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources8 Radioactive sources for external beam radiotherapy l In practice 137-Cs and more importantly 60-Co units need to be considered MDS Nordion

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources9 Radioactive sources for EBT l High activity (>100TBq (3000 Ci)) l Small (height and diameter a few centimeters) l Relatively long half life of 5.26 years for 60-Co and 30 years for 137-Cs l Has been source of a major radiation accident in the past… (Goiânia)

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources10 A teletherapy 60-Co source 5cm 120TBq

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources11 Radiation accident in Goiânia l End 1985 in Brazil l Private radiotherapy unit moved location leaving a 137-Cs unit in former premises l Authorities were not notified l Cs unit was scavenged as scrap metal

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources12 Goiânia accident l Source assembly sold to scrap yard l ‘Glow in the dark’ caused attraction l Parts of the source distributed widely...

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources13 Goiania accident l Several persons showed gastrointestinal symptoms due to irradiation l One affected person contacted public health department l A local physicist was involved in determining the extent of the accident and initiated evacuation of affected areas

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources14 Large scale accident Human Costs l 249 people contaminated l Four people died within 4 weeks

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources15 Environmental and financial costs l Lots of work l Lots of costs l Lots of waste

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources16 Radioactive sources for brachytherapy l Many different isotopes and forms as discussed in part 6 of the course l Brachytherapy isotopes are in radiotherapy practice the most likely cause of concern for security and disposal of sources

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources17 Other sources

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources18 Other sources l Check sources for dosimetric equipment l Check sources for shielding l Except for sources for unsealed source radiotherapy (dealt with in the course on nuclear medicine) all sources can be considered sealed In practice a small part of the radioactive inventory of a radiotherapy department - the considerations in regards to security and disposal for these sources are similar to brachytherapy sources

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources19 2. Security of sources l BSS 2.34: “Sources shall be kept secure so as to prevent theft or damage and to prevent any unauthorized legal person from carrying out any of the actions specified in the General Obligations for practices of the Standards (see paras ), by ensuring that: (a)control of a source not be relinquished without compliance with all relevant requirements specified in the registration or licence and without immediate communication to the Regulatory Authority, and when applicable to the relevant Sponsoring Organization, of information regarding any decontrolled, lost, stolen or missing source;”...

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources20...and... (b)a source not be transferred unless the receiver possesses a valid authorization; and (c) a periodic inventory of movable sources be conducted at appropriate intervals to confirm that they are in their assigned locations and are secure.”

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources21 Security of sources l Not a problem for X Ray equipment if one assumes that n they are properly designed and maintained (compare part 10 of the course) n only authorized persons are able to operate the equipment n unit cannot be accessed by un-authorized persons

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources22 Linac Console Key required for operation

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources23 Security of sources l All radiation equipment must be locked when not in use...

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources24 Security of 60-Co sources l In teletherapy units: n Mainly a feature of equipment design n Treatment rooms must be locked n Source transfer only be done by qualified persons n Great care must be taken when disposing the source - it MUST be returned to an authorized person or company!!!

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources25 Must know the source housing and exposure mechanism design Source Hg pumped in and out Exposure mechanism

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources26 Security of brachytherapy sources l Some info in part 6 on sources l May affect all aspects of source utilization: n receipt of sources n storage n handling n use on patients n disposal 125-I seeds - Courtesy Mentor

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources27 Safety Assessment l Identification of the mechanisms for exposure (both routine and accidents) l Realistic estimate of doses and likelihood of occurring l Identification of possible safety system failures l Identification of protection measures needed

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources28 Source Storage Source stores must: l provide protection against environmental conditions l be only for radioactive materials l provide sufficient shielding l be resistant to fire l be secure

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources29 Features of source storage l Secure (lock and key) l Labels l Different compartments l Shielding l Easy access l Well organized

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources30 Important to keep a good log book l Update with every source movement l Clear labels l Identify all sources l A drawing of the safe outline may be useful

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources31 Source transport l Always accompanied by qualified person l Details in part 14 of the course

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources32 Accountability of sources l Receipt, storage, use and all movements of a source must be recorded

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources33 Accountability of Sources Source accountancy records should contain: Source accountancy records should contain: n radionuclide and activity of sources n location and description of sources n disposal details The records should be updated regularly, and the location of the sources checked. The records should be updated regularly, and the location of the sources checked.

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources34 Testing and Maintenance l Testing of safety systems l Calibration and testing of radiation monitors l Leak tests of sealed sources l Periodic examination of safety critical components

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources35 Testing and Maintenance l Documentation must exist for all procedures: n How to be done n Who is responsible n How often to be done Records of results must be kept

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources36 A lost source... l A major concern for radiation protection l Possible in case of: n Discharge of patients with temporary implants not completely removed n In theatre during implant of radioactive seeds Seeds are small

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources37 A lost source l In theatre a physicist should be present to identify a lost source immediately l Can be located often best using a radiation detector

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources38 A lost source in the ward l Notify physicist or radiation safety officer immediately l Have a plan for the search...

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources39 A lost source? l Need an emergency plan Main actions

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources40 3. Disposal of disused sources l A potential for accidents l Disposal routes should already be considered when ordering sources l Accounting for sources includes their disposal l Responsibility for sources only ends after they have been safely disposed and disposal has been documented

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources41 BSS Appendix III: PUBLIC EXPOSURE - Radioactive Waste l III.8. “Registrants and licensees shall: (a) ensure that the activity and volume of any radioactive waste that results from the sources for which they are responsible be kept to the minimum practicable, and that the waste be managed, i.e. collected, handled, treated, conditioned, transported, stored and disposed of, in accordance with the requirements of the Standards and any other applicable standard; and (b) segregate, and treat separately if appropriate, different types of radioactive waste where warranted by differences in factors such as radionuclide content, half-life, concentration, volume and physical and chemical properties, taking into account the available options for waste disposal.

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources42 Radiotherapy X Ray equipment l In practice usually not a problem n as no parts of the equipment are activated n if the unit is properly ‘decommissioned’ n the unit is disposed off either in a condition which renders it unusable or sold to an appropriately licensed person - this also includes donations n the regulatory authority is informed

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources43 Disposal of teletherapy sources l Due to their high activity (even when not anymore fit for use on patients) the disposal of these sources poses a potential risk for severe accidents… l In practice this should not a be major problem if the source is replaced - in this case the manufacturer of the source shall also accept the source to be disposed

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources44 Potentially a problem if the teletherapy unit is decommissioned l The source should be disposed to an operator licensed to do so n this could be expensive… but is cheaper than an accident l Appropriate transport containers must be used

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources45 Please note l A hospital is NOT a suitable place for long term storage of high activity sources l The source housing is usually NEITHER suitable for transport NOR for long term storage of the source

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources46 Brachytherapy source disposal l Permanent implants ‘walk out with the patient’ n remaining sources must be disposed of appropriately l For temporary implant sources the disposal depends on activity and half life: n short/medium half life, low/medium activity (e.g. 192-Ir LDR sources) can be stored until decayed to an activity which is below limit values specified by the regulatory authority n this strategy does not work for high activity 192-Ir HDR sources or 137-Cs

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources Ir HDR sources l Typically exchanged l Need trained personal for exchange l Storage not recommended

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources Cs sources l Despite half life of 30 years most manufacturers only specify a useful life of 10years. This is mainly due to: n risk of damage to the encapsulation n e.g. Cs pellets in Microselectron ‘bump’ into each other during loading of the applicators l Wipe tests required l Disposal only to person authorized to accept sources

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources49 A note on the role of suppliers l BSS appendix IV.9. “In addition, and where applicable, registrants and licensees shall make suitable arrangements with suppliers of sources: (a) to establish and maintain mechanisms for suppliers to obtain information from the registrants and licensees or other users on the use, maintenance, operating experience, dismantling and disposal of sources, and in any particular normal or abnormal operating conditions that may be important for the protection of individuals or the safety of the source;…” Safety and security of sources is everyone's responsibility

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources50 Summary l Safety and security must be considered for all sources in radiotherapy l Security of sources relies on a system of accounting for sources l Disposal of sources is a major responsibility of the licensee - sources must only be disposed to an authorized person or company

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources51 Where to Get More Information l Parts 6, 10 and 11 of the course

Any questions?

Question: Please discuss what records should be included in a system for accountability of sources used for external beam radiotherapy

Radiation Protection in RadiotherapyPart 15: Security and disposal of sources54 The records should include: l Name of authorized person l Licensee and license conditions l Who ordered the source and when l Supplier (including address, license details and contact details) l Source specifications (chemical form, l Date delivered, received by l Source certificate l Installed by l List of tests performed l Name and contact details of person for emergencies (e.g. RSO) l Record of ongoing relevant QA (e.g. wipe tests, activity verification) l Any incidents (stuck source?) l Any changes to licensing conditions l Decommissioning details l Disposal details (name and license of the person/company the source was disposed to)