Masterpact LV power air circuit breakers and switch disconnectors

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Inspection & Preventive maintenance of breakers
We thought it was a GOOD IDEA, so we did it! We were the first to have quick make-quick break operators on bolted pressure contact switches.
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
M iniature circuit breakers to UL 489
HYDRAULICS & PNEUMATICS
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Circuit Breakers and Busbars. Circuit Breakers Altech’s Circuit Breaker Line UL1077 (R-Series) UL508 (V-EA Series) UL489 (L-Series, AB-Series)
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
SYMAP-BC SYMAP-BC.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
October, 2009 VM1: innovation in power technology Vacuum circuit-breaker with magnetic actuator Product presentation 1VCP – Rev. C, en – Presentation.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
Miniature Circuit Breakers (MCB) Multi 9
Breaker Basics Welcome to this general overview of ABB.
Multi-function apparatus for secondary distribution
Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO
Electro-Pneumatics Module 1
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
Lesson 9: Electrical Components
Pole Mounted Switch Disconnector NPS
Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE.
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
MKT May 2012 C850: Fast sliding gate operator. MKT May 2012 Summary  Why a fast slider operator?  USPs  Applications  Details  Technical specifications.
AQ 100 Series Arc Flash Protection System. Characteristics of arc protection Speed, no intentional delays Sensitive, current set-points just above loads.
PowerIT Air Insulated Cubicle Uniswitch
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Main contacts closed – RED Colour with ON
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
Gates automation. Summary  Choosing the appropriate model  Faac Product Range (Sliding Gates)
R-Series Rotary Disconnects
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
ACTIVE LEARNING ASSIGNMENT TOPIC NAME :- DC MOTOR STARTERS ELEMENTS OF ELECTRICAL DESIGN ( ) AY Course co-ordinator:- SAMIR B PATEL PREPARED.
1 Comparison of 100-B and 100-D Contactors B Contactors.
Circuit Breakers CBI and ETA product offerings. Breaker Technologies - Hydraulic-Magnetic Not effected by ambient temperatures Possible to obtain any.
Sub Station.
SPD II 1 for LV Power (AC/DC)
Product Training Module
C1300 advanced circular chart recorder
3AH5 Vacuum Circuit-Breaker For Standard Applications
DESCRIPTION AND GUIDE TO OPERATIONS
GROUND-FAULT GROUND-CHECK MONITOR
PRESENTATION ON SUMMER TRAINING PROGRAM
Circuit Breakers & Reclosers
Overview of PowerCube Units and ANSI frames
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Direct Replacement Retrofitting Solution
SION Vacuum Circuit-Breaker For Standard Applications
VCB Cassette Switchgear DESCRIPTION AND GUIDE TO OPERATIONS
ELECTRICAL POWER-II Electrical engineering sixth semester
ABB SACE Emax 2 ANSI C37 / UL1066 Concept Global Product Management
Direct Replacement Retrofitting Solution
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
Presentation transcript:

Masterpact LV power air circuit breakers and switch disconnectors 1

Function Masterpact circuit breaker are used to protect and control low voltage distribution system. Masterpact circuit breaker may be installed in main LV switchboards (incoming units, main and secondary outgoers).

Features Ratings from 800 to 6300 A AC, from 1000 to 8000 A DC Breaking capacity from 40 to 150 kA rms (N1, H1, H2) Operational voltages 690 V AC, 1000 V DC; 3 or 4 poles Fixed or drawout version Wide range of control units offering multiple function Comply with all the major international standards: International standard: IEC 947-2, North American standard: UL489, ANSI C37-50, CSA C22-2, NEMA AB1 to SG3, Japanese standards: JIS 160 and C 8372 Comply with national standards: France: NF C63-120 Germany: VDE 0660 United Kingdom: BS4752 Australia AS Italy CEI;

Features Mechanical endurance : with maintenance co cycles : 20,000 (M08 - M16); 15,000 (M20 - M32); 10,000 (M40 - M63) no maintenance co cycles : 10,000 (M08 - M32); 5,000 (M40 - M63) Electrical endurance : with maintenance co cycles (440 V) : 10,000 (M08 - M16); 9,000 (M20); 8,000 (M25); 4,000 (M32); 3,000 (M40 - M50); 2,000 (M63)

Front face 1. Opening push-button (0) 2. Closing push-button (I) 3. Keylock for “connected”, “disconnected” or “test” position 4. Door interlock 5. Stored-energy-mechanism charging handle 6. Operations counter 7. “Open” position keylock 8. Racking handle storage 9. Functional position indicator: “connected”, “test” and “disconnected” 10. Controls on fixed chassis 11. Padlocking facilities for “connected”, “disconnected” or “test” position 12. Stored-energy-mechanism status indicator 13. Main-contact position indicator 14. Fault trip indicator/breaker reset button Stored energy status:

Frame size AC circuit breaker: Masterpact has 4 frames size, they are M08 up to M32, M40, M50, and M63. Common height and depth from 800 A to 6300 A. DC circuit breaker: Masterpact has 5 frames size, they are M10 up to M32, M40, M50, M63, and M80. Common height and length from 1000 to 4000 A for operational voltages greater than 500 VDC.

Drawout version 1. Arc chute cover 2. Auxiliary terminal shield 3. Auxiliary connection block 4. Fixed chassis 5. Safety shutters 6. Arc chute 7. Remote control voltage release 8. Motor for electrical charging of stored energy mechanism 9. Control unit (AC system) 10. Front cover

Safety and reliability Reduced, simple maintenance; Double insulation from the front face; Positive contact indication; Auxiliary devices can be fitted on site without adjustment A trip interlock ensures that the circuit breaker is open during connection and disconnection Connection to top or bottom terminal Fully tropicalised as standard

Stored energy operating mechanism Masterpact circuit breakers are operated via a stored energy mechanism for instantaneous opening and closing. The mechanism is charged either manually or electrically. Closing and opening operations can be initiated either from the local push buttons on the circuit breaker front face, or by remote control.

Other possibilities Fixed circuit breaker The fixed circuit breaker is derived from the moving part of the drawout circuit breaker by adding a fixing bracket on each side. 1000 VAC circuit breakers. Source changeover system (two solutions) : Mechanical interlocking for 2 or 3 circuit breakers Automatic source-changeover controller, easy to implement on any two suitably equipped circuit breakers (electrically charged operating mechanism, etc)

Device identification M 20 H1 Breaking capacity : N1 : standard; H1 : H2 : high performance L1 : current limiting DC : direct current Rating : Rated current / 100 Family : Masterpact: LV power air circuit breaker

Conformity with standard Ui: rated insulation voltage Ue: rated operational voltage Icu: ultimate breaking capacity, for various values of the rated operational voltage Ue Ics: service breaking capacity Icw: short-time withstand current

Degree protection Circuit breaker installed free standing: IP30-5 Circuit breaker installed in a cabinet with access to controls through a door cut-out: IP40-5 Circuit breaker installed in a cabinet behind a door with a cut-out fitted with a sealed, transparent cover: IP54-9

Control unit selection Masterpact M08 to M63 circuit breakers are equipped with microprocessor based electronic control units. All the protected functions are powered by the AC system and no auxiliary power supply is required. Each control unit of the Masterpact range corresponds to a certain type of application (instantaneous, distribution, selective, universal). All the STR control units measure the true rms value of the current and are therefore not affected by harmonics that may be present on the system.

Control unit accessories Interface module (ET44) Compulsory with the data transmission option on the STR 68, this interface module allows: setting of the transmission speed, definition of the address of the breaker, and direct remote of the breaker. Relay module (MR6) For relaying of information from outputs of modules m01 to m31 of control unit STR 68 via output changeover contacts 10 A/220 V AC or 3 A/24 V DC Power supply module (AD) The module can be used to power control unit complementary functions which can’t be self-powered by the built in CT. Battery module (BAT) Providing to complement to the AD module, the battery module provides

Auxiliaries Electrical operating mechanism Added to the manual charging mechanism, a motor charges and automatically recharges the stored-energy spring upon breaker closing making possible fast O-C-O cycles. Operation counter With gear-motor option only. The operation counter is read from the front and gives the total number of breaker operating cycles. Releases Two types of voltage release: undervoltage release (MN [instantaneous] & time delayed [MNR) and shunt release (MX)]. For undervoltage release, the breaker will open, If the supply voltage drops between 35% and 70% of Un. Closing is possible when release voltage reaches 85% Un. Closing release This device releases the breaker closing mechanism when the spring is charged.

Accesories Auxiliaries switches Three auxiliary switch blocks are standard - 4 contacts (O), optional - 4 directly-operated double break changeover switches (OF), optional - 24 additional changeover switches (OFSUP block). Ready to close contact (PF) This contact indicates the breaker is open, the stored-energy mechanism is charged, the mechanism is correctly reset, the breaker opening pushbutton is not locked, no opening order is present. Spring charged contact (CH) In addition to the local mechanical indicator and the “ready to close” contact, the gear-motor limit switch changeover contact can indicate that the operating mechanism is ready (spring charged). Fault trip indication (SDE) Safety shutters (VO) Mounted on the fixed portion of drawout breakers, the safety shutters automatically block access to the disconnection contacts when the breaker is in the disconnected or test position (IP20). Shutter lock (VVC) To lock the shutters in the closed position and hold the shutters in the open position.

Accesories Arc chute cover (CC) This cover eliminates the safety clearance requirement above the breaker. Terminal shield (CB) This cover prevents access to the electrical auxiliary connection terminals. Interphase barries (EIP) The insulated partitions for vertical installation between connection pads to reinforce insulation at connection points and to prevent arc propagation in the event of a line side fault Partitioning fixture (AC) Attached to the fixed portion of drawout breakers. This fixture provides IP30 partitioning between breaker compartment and connection zone. Door frame (CDP) This frame provides an equipment seal function (IP405). Suitable for fixed and drawout patterns. Transparent cover (CCP) This is designed for the door frame (CDP). It provides a degree of protection of IP549. Suitable for fixed and drawout patterns.

Accessories Auxiliaries for fixed version Connection by one or two plugs, disconnectable and accessible from the front. Auxiliaries for fixed version The breaker auxiliary circuits are connected by connection blocks that operate automatically to isolate the auxiliaries when breaker is in “disconnected” position. Breaker mismatch protection For drawout version only, this systems allows only correctly matched breakers (rating, type wiring, etc.) to be inserted in a given fixed frame. Earth protection The earth connection terminal (drawout pattern) is on the left hand side of the chassis. It’s marked with the symbol . Push button locking device This padlockable device (padlocks not supplied) prevents direct operation of the circuit breaker by covering the “on” and “off” pushbuttons. “Off” position locking device A Profalux key lock locks the breaker in “off” position by holding the pushbutton in its depressed position.

Accessories “Disconnected”, “connected” and “test” position locking Mounted on the frame and accessible with the cubicle door locked, this system is available in two versions: “disconnected (standard)” and “disconnected, connected, test (optional)” position locking. Door interlock Mounted on the chassis, this lock prevents the cubicle door from being opened when the breaker is in the “connected” position. If the breaker is put into the “connected” position with the door open, the latter can be closed without disconnecting the breaker. Racking interlock This lock prevents insertion of the breaker racking handle when the cubicle door is open. It can be defeated by pressing on the unlocking mechanism. Withdrawal/spring charged interlock This lock prevents withdrawal of the breaker from the chassis when the spring are charged.

Automatic source-changeover systems Masterpact source-changeover systems can be used to implement various configurations involving several incoming feeders. The two or three Masterpact CB or switch-disconnectors used are mechanically interlocked to prevent certain combinations of operations. The devices may be arranged : Vertically, I.e stack-mounted and interconnected by a set of rods; Horizontally (two only), I.e side by side and interconnected by a set of cables.

Automatic source-changeover systems with 2 devices A Masterpact automatic source-changeover system with 2 devices is made up of : CB QN connected to the “Normal” source CB QR connected to the “Replacement” source Mechanical interlocking system by rods or cables; Automatic control of the system can be provided by adding : Electrical interlocking unit IVE Auxiliaries control plate ACP Controller BA or UA Each Masterpact CB is equipped with : a motor mechanism a shunt release (MX) a ready to close contact (PF) a block of 4 changeover switches (OF) an additional terminal block (BS) and a block of 4 connected position switches (CE) for source-changeover systems made up of drawout breakers.

Automatic source-changeover systems with 3 devices A Masterpact automatic source-changeover system with 3 devices up of : 2 CB QN1 and QN2 connected to the “Normal” source; CB QR connected to the “Replacement” source; Mechanical interlocking system by rods; For such applications (consult us) automatic control of the system can be provided by adding : 2 electrical interlocking unit IVE auxiliaries control plate ACP controller BA or UA Each Masterpact CB is equipped with : a motor mechanism a shunt release (MX) a ready to close contact (PF) a block of 4 changeover switches (OF) an additional terminal block (BS) and a block of 4 connected position switches (CE) for source-changeover systems made up of drawout breakers.

Automatic source-changeover systems controller option selection Used together with the auxiliaries control plate ACP, controller BA and UA initiate the automatic changeover operations according to the status of the “Normal” and “Replacement” sources. Installation Mounted directly on the auxiliaries control plate ACP. Mounted on the front of the switchboard. The distance between the controller and the auxiliaries control plate must not exceed 2 m.

Automatic source-changeover systems controller option selection (controller BA) Controller BA can be used with Masterpact CB to implement a straight forward automatic source-changeover system. Electrical characteristics Power is supplied from the auxiliaries control plate ACP. The same voltage must be used to supply the ACP plate, the IVE unit and the CB motor mechanisms. Otherwise, BC type or equivalent isolation transformer must be used. Operation a four-position switch can be used to select: automatic operation, forced operation on source N, forced operation on source R, and stop. Adjustment of time delays in front: t1 = time delay before QN opens when the voltage UN of the Normal source disappears, it can be adjusted from 0.1 to 30 sec. t2 = time delay before QR opens when the voltage UN of the Normal source is restored, it can be adjusted from 0.1 to 240 sec. CB status indication on the front of the controller: on, off, fault trip.

Automatic source-changeover systems controller option selection (controller UA) Controller UA offers the following automatic functions: switching from one source to another depending on the presence of voltage UN on the Normal source control of an engine generating set shedding and reconnection of non-priority circuits switching to the Replacement source in the event of a failure on one of the phases of the Normal source Electrical characteristics Power is supplied from the auxiliaries control plate ACP. The same voltage must be used to supply the ACP plate, the IVE unit and the CB motor mechanisms. Otherwise, BC type or equivalent isolation transformer must be used.

End presentation