Simulation of Created Design Documentation on the simulation process of a basic injector-separation channel model design.

Slides:



Advertisements
Similar presentations
Analog Basics Workshop Getting started with Tina-TI
Advertisements

1 SESSION 6 Using tables and graphs in project work.
Summary Statistics/Simple Graphs in SAS/EXCEL/JMP.
Never lose your data again!
AS ICT Building MS-Access Databases. Creating a Combo Box Drop Down List 1.When creating a Field requiring a Drop Down list in a Table, select the Lookup.
1 After completing this lesson, you will be able to: Specify options. Customize the appearance of messages. Add a signature to an .
How to Import an Excel File Using the SAS Import Wizard SAS 9 for Windows.
Sweeping a Variable Resistor Wheatstone Bridge. Place the Parts 1.VDC 2.R, which you place 3 times. The numbering of the resistor increases sequentially.
Getting Started with Cadence Compiled by Ryan Johnson April 24, 2002  Open Orcad Capture under Engineering Software  Under FILE, choose NEW, PROJECT.
1. Chapter 29 Creating Forms 3 Understanding Forms Word enables you to create fill-in forms to eliminate the need for storing pre-printed forms. Add.
CPIT 102 CPIT 102 CHAPTER 1 COLLABORATING on DOCUMENTS.
LNA Simulation Tutorial
PSPICE Tutorial Spring 2015
MODULE 5 B WORD PROCESSING. cont How to Add Colour to Your Microsoft Word Logo To add a coloured background to your shape, do the following: Make sure.
SP2006 CSE598A/EE597G CAD Tool Tutorial Spring 2006 CSE598A / EE597G Analog-Digital Mixed-Signal CMOS Chip Design.
Getting Started with Layout Compiled by Ryan Johnson May 1, 2002  Open Orcad Capture under Engineering Software  Under FILE, choose NEW, PROJECT  The.
Microsoft Excel 2010 Chapter 7
ECE – 329 Fall 2007 Lab Manual for Xilinx Example: Design and simulation of a Half Adder Instructor: Dr.Botros.
XP New Perspectives on Microsoft Office Access 2003, Second Edition- Tutorial 2 1 Microsoft Office Access 2003 Tutorial 2 – Creating And Maintaining A.
How to use the VHDL and schematic design entry tools.
This presentation contains the following: -the availability and need menu options -the add option Mark Smith.
Using Excel for Data Analysis in CHM 161 Monique Wilhelm.
Getting Started with Cadence Prepared by Ryan Johnson, 2002  Open Orcad Capture under Engineering Software  Under FILE, choose NEW, PROJECT  The following.
Creating And Maintaining A Database. 2 Learn the guidelines for designing databases When designing a database, first try to think of all the fields of.
Design Process of Serpentine Channel Documentation on the design of a basic injector-separation channel model design.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
Abdülkadir ERYILDIRIM Turgut Ozal University. The Objectives:  Open and Save New Project File  Create a Circuit Schematic  Get Place, Place Parts i.e.
Copyright © Texas Education Agency, All rights reserved. 1 Web Technologies Website Development with Dreamweaver.
SMART Response Initial Set-up: Windows PC Teacher and Class Set-up Creating a Quiz, Test, or Survey Delivering an Assessment Reports Additional Question.
Turning Glowing Text into Animated Glowing Text Using Animation Shop.
Mentor Tools tutorial Bold Browser Design Manager Design Architect Library Components Quicksim Creating and Compiling the VHDL Model.
Copyright © 2007, Oracle. All rights reserved. Managing Concurrent Requests.
Visual Solutions, VisSim Overview VisSim program can be used to simulate some of the control problems in the DPCL. Review the following:
Simulink ® Interface Course 13 Active-HDL Interfaces.
 Enter username and password into Novell screen.  Click “ok” and wait for desktop to load.  When desktop loads, open Microsoft Word using the icon.
WS09-1 VND101, Workshop 09 MSC.visualNastran 4D Exercise Workbook Belted Cylinder.
Using Microsoft Word & Excel §Open a new document in MS Word §Click on Tools & then Mail Merge l a dialogue box, like the one on this page, will appear.
USING A TABLE OF VALUES TO ESTIMATE A LIMIT. Use a table of values to estimate.
Instructions.  Open up the letter that Adam has given to you  Format it so it look professional.
MWO – APPLICATION IN FILTER DESIGN Soh Ping Jack Sabarina Ismail.
Objectives Understand the design environment and flow
SPSS- Tutorial The following power-point slides show you how to use some of the features in SPSS. A survey of 20 randomly selected companies asked them.
Lab 4 Experiments 8 and 9. Same Circuit: Experiment 8 and 9.
line.net/ okpop.com/bar elythereflashin dex.html.
Using skype for business to share desktops
Links take you to…  Different slides in your presentation  A different PowerPoint presentation  Any program - (Word can be used for example to complete.
Getting started with MATLAB/Simulink
1 Microsoft Project 2003 Starting a New Project. 2 Creating a new project plan To start Microsoft Project, click the Windows Start menu. Point to All.
This is how you invoke the Microsoft Visual Studio 2010 Software. All Programs >> Microsoft Visual Studio 2010.
Adding Contacts in Outlook. Follow these steps to begin building your contacts! By adding contacts in your Outlook, you will be able to develop an organized.
WS 9-1 ANSYS, Inc. Proprietary © 2009 ANSYS, Inc. All rights reserved. February 27, 2009 Inventory # Workshop 9 Taylor Impact Test – “What if” Study.
Sorting Contacts with Categories Lunch and Learn.
Serpentine Channel Demonstration Documentation on the setup and simulation of a complete basic injector-separation channel model design.
It’s always important that all of your nodes be numbered. So the way to do that is to go to Options at the top of the screen then select Preferences. When.
Copyright © 2007 by Pearson Education 1 UNIT 6A COMBINATIONAL CIRCUIT DESIGN WITH VHDL by Gregory L. Moss Click hyperlink below to select: Tutorial for.
Excel Functions. Part 1. Introduction 2 An Excel function is a formula or a procedure that is performed in the Visual Basic environment, outside the.
Transient Response. Transient Analysis Plot of the voltages or currents as a function of time. – Output plot mimics the oscilloscope display. If simulating.
Personal Planning System The Merging a New Plan Enterprise Edition.
Select a work instruction
How to Change a Microsoft Word Document to a PDF Fillable Form!
Customizing the Quick Access Toolbar in Microsoft Office
DRAWING LINES To draw lines click View in the Main Menu Toolbar -> Toolbars and check the Editor option. The Editor toolbar will appear amongst the toobars.
Mail Merge And Macros in MS WORD
T_C_N_L_G_ E D I D I E O Y O H I E B J I R E A A W.
Introduction to SPSS 16.0 Part 2
S-parameters measurements
Download: Vensim Download:
Creating User Defined Fields (NDF)
Microsoft Office Access 2003
Large View of Compress Pictures Tool
Presentation transcript:

Simulation of Created Design Documentation on the simulation process of a basic injector-separation channel model design

The Simulation Process In this simulation, a sample will be passed into the injector, and ‘Injected’ into the separation channel This is where the different species of the product will begin to separate from each other A signal of when each species passes a detector will be taken and plotted

Getting to the Simulation Window In order to simulate the design, the simulation window named “Cadence Analog Design Environment” needs to be opened To do this, go into the toolbar menu: Tool-> Analog Environment

Getting Variables The Variables that were used when adding the objects need to be added into the simulation variables This is done by selecting Variables -> Copy From Cellview from the toolbar, this will pick all the variables in the schematic

Editing Variables - I Now the values of those variables need to be changed To change them select Variables -> Edit from the toolbar, or click on the following side toolbar button

Editing Variables - II To change the values, type the value into the Value (Expr) field and click on Change Then select the Next variable from the table and continue Enter the following table of values, V1D and V3D need to be close to V4D value to prevent much of a voltage difference between the two V4L12.5 V4D3000 V3L0 V3D2900 V2L52.5 V2D0 V1L22 V1D2900 mu mu LOA D 0 D1400 D0400

Selecting Outputs In order to neatly see the results from the simulation, outputs are needed To select output, in the toolbar menu, go to: Outputs -> To Be Plotted -> Select On Schematic This will open up the schematic window again

Selecting the Pin In the Editor window, the values of wire that is selected will be plotted in a graph when the simulation is run So, select the ‘conc ’ output pin on the first detector and the ‘conc_out ’ output pin on the second detector

Output Plots When the conc pin is clicked a box pops up and when it is clicked again, conc and conc get highlighted, click OK, the two come under Outputs follow the same procedure for conc_out too

Choosing the Analysis To select the simulation type, click on the “Choose Analyses...” button on the side toolbar

The DC Analysis In the “Choosing Analyses” window, select dc, Enabled, and Save DC Operating Point and click OK

The First Simulation Once all the values have been inputted, click on the toolbar menu: Simulation->Netlist and Run on the toolbar menu or click the “Netlist and Run” button on the side toolbar

The Log File After this simulation has been run, a log file will appear This file is the results of the simulation and has some values that need to be inputted into the design

Edit the Properties Some properties of the injector need to be changed To do this go to: Edit -> Properties -> Objects… q

Editing Properties Input the values from the log file of the currents and concentrations into the corresponding properties of the injector, i.e., current 1 = cur_I1 etc One change that needs to be done to the values is that they should all be inputted as positive numbers

Another Analysis Another Analysis needs to be done, so go to the “Choose Analyses” Window again

Transient Simulation In the “Choosing Analyses” Window, Select tran and Enabled, then set the Stop Time to ‘1.5’, check conservative, and click the Options... button

Editing the Transient Simulation In this window, Set the start field to 0, and set the values of the step and maxstep fields to ‘.001’ Then click OK and get back to the simulation Window

Simulating Once all of the values are inputted, the only thing left to do is to simulate This can be done by clicking on the Netlist and Run on the side toolbar button This simulation may take a little longer than the previous one

The Final Output After the Simulation finishes, a ‘Waveform Window’ will appear with the desired plot on it This plot shows the outputs at the selected pin

Understanding the plot Click on the Curves-> Edit and we will be able to set some outputs to off and on to better understand the plot Increase the number of data points by going to “Cadence Analog Environment window” selecting Analysis in the side toolbar and clicking Options and changing the step and max step to get a more accurate plot Changing the voltages may increase or decrease the time the species tested need to approach the detector Change in the mobilities might separate or reduce the space between the two species

Finishing up Now we will save the current state of the simulation Go to Session->Save State … and save it as state2

Finishing up Now we can close all the open windows