Implantable Cardioverter Defibrillator Rebecca Boduch Biomedical Engineering University of Rhode Island.

Slides:



Advertisements
Similar presentations
Cardiovascular Diseases
Advertisements

A Look Into Congestive Heart Failure By Tim Gault.
Subcutaneous Implantable Cardioverter Defibrillator (S-ICD)
Automated External Defibrillation
Samone and Sarah.  The heart muscles become enlarged.  The walls of the heart thicken, which prevents the heart from functioning properly.
How can you prevent cardiovascular disease?.  A disease that is not transmitted by another person, vector, or the environment  Habits and behaviors.
Cardiovascular Diseases
Heart Failure: Living with a Hurting Heart. Congestive Heart Failure Heart (or cardiac) failure is the state in which the heart is unable to pump blood.
Defibrillation 4/19/2017
Prepared by : Nehad J. Ahmed.  Heart failure, also known as congestive heart failure (CHF), means your heart can't pump enough blood to meet your body's.
ICD FOR PRIMARY PREVENTION EVIDENCE REVIEW
Congestive Heart Failure (CHF)
 Lifestyle Changes Can help a patient suffering from: ◦ Coronary Heart Disease, Heart Attacks & Congestive Heart Failure  Reduce amount of salt intake.
Co-ordination of the Cardiac Cycle Aims Describe how heart action is coordinated with reference to the sinoatrial node (SAN), the atrioventricular node.
E LECTROCARDIOGRAM AND THE D IAGNOSIS OF C ONGESTIVE H EART F AILURE By Angela Thomas.
Sudden Cardiac Death in Heart Failure Trial Presented at American College of Cardiology Scientific Sessions 2004 Presented by Dr. Gust H. Bardy SCD-HeFTSCD-HeFT.
Chapter 6 AED.
Arrhythmias Medical Student Teaching Tuesday 24 th January 2012 Dr Karen Jones, SpR Emergency Medicine.
By: Kyra Alexander.  Heart Failure is a condition in which the heart cannot pump enough blood into the rest of the body.  Often a long-term (Chronic)
Arrhythmia Tasha McDevitt Patient Care Sciences II Inst: Dr. Hoeff.
Dean Handimulya UIEU 2005 Congestive Heart Failure Dean Handimulya, M.D.
Cardiac Arrest Mirna Gonzalez Ninth Grade- 14 years of age.
Cardiac Arrhythmias in Coronary Heart Disease SIGN 94.
Shannen Whiddon.  Cardiac tamponade is a condition in which cardiac filling is impeded by an external force.
Cardiovascular Problems
Preventive behaviors can reduce the risk for cardiovascular disease and stroke.
Your heart is a muscle that works continuously like a pump Each beat of your heart is set in motion by an electrical signal from within your heart muscle.
Congestive Heart Failure By: Ashley Morgan and Kendra Mclhenny.
Cardiovascular Diseases Why should you establish and maintain healthful habits to care for your heart?
Non-Communicable Diseases. What are Non-Communicable Diseases? Any disease that is _______________ spread from one living thing to another Any disease.
Cardiovascular System
Cardiac Conditions Caring for children with cardiac conditions in a community program
Co-ordination of the Cardiac Cycle SBI3U. The heart is made of cardiac muscle. When the cells receive an electrical impulse they contract - causing a.
Abnormalities of the Conduction System Elizabeth Dugan - Olamide Odubogun -
Sick Sinus Syndrome. Description Your sinus node controls the rhythm of the heart. It sends electrical impulses across the atria to the ventricles, making.
ELECTRODES FOR STIMULATION. Cardiac Pacemakers and Defibrillators  The heart is a natural example of a critical Bioelectromagnetic system.  An electrocardiogram.
Rhythm Strips Jessica Wagner UMSON. EKG Grid.
Frank-Starling Mechanism
Medical Treatments for Heart Disease Chapter 17 Section 5 Amy Bentle and Amanda Jones.
Bell Ringer What are Three adaptations for the fetal circulations?
IMPLANTABLE DEFIBRILLATOR By: Victor J. Gabbidon.
Heart Failure Devices: Staying Connected Lisa D. Rathman, MSN, CRNP, CCRN, CHFN The Heart Group of Lancaster General Health Lancaster, PA.
How the Heart Works. Electrical activity in the heart.
Objectives 1. Discuss heart sounds 2. Describe the major types of cardiac valve disorders 3. Explain how a myocardial infarction might occur. 4. Describe.
The Heart. Pulmonary Circulation and Systemic Circulation The heart is considered to be a double pump because it pumps blood through 2 different loops:
HEART By Joe Burr. Your heart Your heart is one of the most important organs in your body, if it stops you will slowly die. Your heart is mostly just.
Don’t Worry I am Ok! Goal of project GOAL OF PROJECT  TO AWARE ABOUT HEART DISEASES.  TO UNDERSTAND CAUSES OF HEART DISEASES.  TO AWARE PREVENTIVE.
Cardiovascular Issues 13(d). Overview of the Heart.
Cardiovascular Disease Lesson 14.2 Page 414 in the book “Disease of the Heart and Blood Vessels”
THE HEART’S ELECTRICAL SYSTEM Marco Perez, MD Center for Inherited Cardiovascular Disease Inherited Cardiac Arrhythmia Clinic June 20, 2013.
Diseases of the Heart Anatomy The Circulatory System.
1 Automated External Defibrillator. 2 Sudden Cardiac Arrest Sudden cardiac arrest is the most common cause of death in Australia. Sudden Cardiac Arrest.
Cardiovascular System. It is know as the “transportation” system of the body Structures of the Cardiovascular system Major structures of the CV system.
Defibrillation 10/24/2017
Ventricular Tachycardia (VT)
American College of Cardiology Presented by Dr. Stuart J. Connolly
AED- Automated External Defibrillation
Heart Failure - Summary
The Cardiovascular System
Hypertrophic Cardiomyopathy
Arrhythmia Arrhythmia.
Automated External Defibrillator Intermediate
Molly Magee Section 2 BME 181 University of Rhode Island
Mahesh Anantha Narayanan et al. JACEP 2017;3:
CARDIOVASCULAR AGENTS
Cardiovascular Disease (2:22)
Mahesh Anantha Narayanan et al. JACEP 2017;j.jacep
The Heart Rhythm Society Meeting Presented by Dr. Johan De Sutter
Automated External Defibrillation
Presentation transcript:

Implantable Cardioverter Defibrillator Rebecca Boduch Biomedical Engineering University of Rhode Island

Heart Disease Ventricular Tachycardia – –The heart had a rapid, regular heart rhythm –The rhythm originates in the lower chambers of the heart Ventricular Fibrillation – –The heart rhythm is irregular, abnormal, and chaotic

Information about Heart Conditions Ventricular tachycardia and fibrillation occur most often in patients that have damaged heart muscle or coronary artery disease When ventricular tachycardia has occurred the heart is pumping fast and in one continuous loop, thus causing the heart chambers little time to fill resulting in dangerously decreased amounts of blood being pumped to the body Ventricular fibrillation the heart is pumping chaotically and the chambers don’t contract properly, causing results in dangerously decreased blood flow

Normal Heart Rhythm

Ventricular Tachycardia Heart Rhythm

Ventricular Fibrillation Heart Rhythm

Implantable Cardioverter Defibrillator Implantable Cardioverter Defibrillator (ICD) has been proven to be an effective way of treating these heart conditions An ICD is implanted under the skin near the collarbone through open chest surgery There are leads that go from the implanted generator down onto the surface of or in the heart There can be different amounts on leads These leads are responsible for detecting and monitoring the heart rhythm

Implantable Cardioverter Defibrillator If an abnormal heart rhythm is detected, the ICD administers a shock to the heart, in order to “reset” the heart rhythm ICD’s have been proven to be an effective way in prevention of death, brain damage, and other complications associated with these heart conditions

Medication vs. Surgery Sudden Death from cardiac causes is the leading cause of death among people with congestive heart failure (CHF) A study was conducted to determine if the drug amiodarone or an ICD improves the prognosis for people living with heart conditions The study has 2521 patients who have either case 1 or case 2 CHF and also a left ventricle ejection fraction of less than 35%

Medication vs. Surgery The 2521 patients were divided into three groups –847 patients were treated with the conventional treatment plus placebos –845 patients were treated with the conventional treatment plus amiodarone –829 patients were treated with the conventional treatment plus a single lead ICD The study was conducted over a 5 year period and patients were followed up every 3 months

Conclusion The results of the study proved that an ICD was more effective. Having an ICD reduced the risk of death by 23% The study also showed that amiodarone had no added effect on the patient prognosis The study helped to prove in favor of ICD therapy

Hazard Ratio

References: "Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure." The New England Journal of Medicine (2005): Print. "Implantable Cardioverter Defibrillator." American Heart Association. American Heart Association. Web. 5 Feb "Ventricular Tachycardia and Ventricular Fibrillation." New York- Presbyterian. Web. 5 Feb