Low-GWP Alternative for Small Rigid PU Foam Enterprises Conversion Demonstration from HCFC-141b-based to Cyclopentane-based Pre-blended Polyol in the Manufacture.

Slides:



Advertisements
Similar presentations
Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Advertisements

Flammable and Combustible Liquids
HVAC523 Heat Sources.
Fire Suppression Techniques Part 2
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
Smooth Transition; Using Safe And Cost-effective Gaseous Blowing Agents The Benefits of HFC-134a & HCFC-22/142b Technology.
The Life Safety Surveyor Facility Tour
The three essential ingredient for creating a fire are HEAT, AIR AND FUEL Fire triangle.
Safe Handling of Flammable and Combustible Liquids
Biofuel teleconference July, 2007 ABNT - Presentation 1.
7 Portable Fire Extinguishers Captain Walker. 2 Objectives (1 of 2) State the primary purposes of fire extinguishers. Define Class A fires. Define Class.
2 THEME The important thing from the point of view of fire safety is – how one interprets these properties. Thorough knowledge is essential to understand.
Fire Safety. Introduction and Unit Overview The role of CERTs in fire safety:  Put out small fires.  Prevent additional fires.  Shutoff utilities 
Workshop on HFC Management and 35th OEWG Meeting of the Parties to the Montreal Protocol Bangkok - Thailand What are the costs of replacing conventional.
DuPont™ FEA-1100: Zero ODP, Low GWP, Non-Flammable Alternative for DuPont™ FEA-1100: Zero ODP, Low GWP, Non-Flammable Alternative for HCFC-141b Helen Walter-Terrinoni.
Developments on the Phase- in of Low GWP Chemicals In Various Polyurethane Sectors Kultida Charoensawad PolyUrethanes Industry Group, Thailand UNEP workshop.
LNG Hazards.
Liquid Fuel Safety Cummins Southern Plains, Ltd..
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Welcome to Your Technology Centre SYSTEM HOUSES AND DEVELOPMENT OF low-GWP TECHNOLOGIES HCFC ALTERNATIVES FOR THE FOAM SECTOR TECHNOLOGIES AND EQUIPMENT.
Air Conditioning EPA Type II.
Standard 29 CFR Part Flammable & Combustible Liquids.
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
Update on alternative technologies and international developments in the Polyurethane Foams Sector.
Ethanol - Experiences and Issues Dr. R.K.Malhotra General Manager IOC, R&D Centre - Faridabad April, 2006.
Flammable and Combustible Liquids
FIRE SAFETY Introduction and Unit Overview The role of CERTs in fire safety:  Put out small fires.  Prevent additional fires.  Shutoff utilities 
Flammable and Combustible Liquids Presented by Martina Schmeling Adapted From OSHA.
HAZARDOUS MATERIALS. OSHA Office of Training and Education - Revised by TEEX 12/05/07 2 Terminal Objective Describe the hazards and requirements of working.
Fire Safety. Fire Safety Introduction Fires ravage 28,000 industrial facilities each year, causing $596 million in direct property damage. Ninety percent.
Fire Prevention for Construction. Four classes of fires  A, B, C, and D 1a.
CXS490 Carbon Dioxide Systems
Safety Training Presentation
WORKSHOP: MANAGING F-GASES THE FOAM INDUSTRY’S NEEDS FOR HFCs FOAM INDUSTRY REPRESENTATION XPS   EXIBA Phenolic   EPFA Polyurethane   ISOPA   BING,
Air Conditioning International Mechanical Code
Flammable Liquids 29 CFR Flammable Materials.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
INDUSTRY PROGRESS AND NEEDS FOR REPLACING HIGH GWP HFC S Montreal Protocol HFC Management Workshop Paris July 11, 2014.
Chubb Hong Kong Ltd. – Fire Safety Division
Fuel Contamination Gasoline into diesel fuel – Problems Lower diesel flashpoint - fire hazard Poor operability for diesel engines, lower cetane number.
Unit 4 Chemistry of Fire. This will be as basic as it gets. Do you remember the Periodic Table?
FLAMMABLE AND COMBUSTIBLE LIQUIDS 1 Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) OSHA 29CFR PPT
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
WELCOME!. Who is T&T Power Group? WELCOME! Who is T&T Power Group? What can we do for you?
About company Kurgankhimmash is the leading Russian company manufacturing process equipment for oil & gas producing, oil & gas refining, chemical, energy,
YOU’VE GOT THE POWER!. When the grid goes down, which type of system do you want for emergency power: battery or generator? Either type will get the job.
Unit 4 Chemistry of Fire. This will be as basic as it gets. Do you remember the Periodic Table?
Flammable Liquids Directorate of Training and Education
Boiler Safety Valve Regulations
Safe Handling of Flammable and Combustible Liquids.
Safe Handling of Flammable and Combustible Liquids
SERVICES, LLC 1 1.
Infrastructure & Safety
What is Desuperheater Water heater and its Applications?
Flammable and Combustible Liquids
Fire protection and prevention
A Comparison of the Physical Properties [& Their Causative Factors] of Froth vs. Pour Foams CPI San Antonio John Murphy Foam Supplies, Inc.
Fire Safety/Extinguisher Use
مایعات قابل اشتعال و احتراق پذیر
Les Shirvill1, Mark Royle2 and Terry Roberts2 1Shell Global Solutions
Safe Handling of Flammable and Combustible Liquids
Portable Fire Extinguisher Overview
Low-GWP blowing agents as alternatives of HCFC-141b
CHALLENGES IN MEETING 2020 HCFC PHASE OUT TARGETS
Introduction to HPMP.
HCFC-141b phase out in PU foam Delhi, 8 February 2019
Presentation transcript:

Low-GWP Alternative for Small Rigid PU Foam Enterprises Conversion Demonstration from HCFC-141b-based to Cyclopentane-based Pre-blended Polyol in the Manufacture of Rigid Polyurethane Foam (CPR/FOAM/59/DEM/491) Feng Hui Foreign Economic Cooperation Office, China Viraj Vithoontien Environment and Natural Resources Global Practice

Background  The demonstration project was approved by the Executive Committee at its 59 th Meeting;  Project entails establishment of capacity at the foam system house to produce polyol pre-blended with cyclopentane, and applications of cyclopentane pre- blended polyol at four downstream foam enterprises;  Project was implemented into two phases. Phase I covered establishment of production capacity at foam system house and conversion at one downstream foam enterprise. Phase II expanded to four downstream foam enterprises.

Project Implementation 3 Wanhua Rongwei Polyurethane Foshan Ouqi Zhanjiang Aowei Zhongshan Minea Electric Appliances Guangdong Vanward Electric Water Heaters Wine Cabinets and Small Fridges Discontinuous Sandwich Panels Commercial Refrigerators Development and Production of HC Pre-blended Polyol

Development and Production of HC Pre-blended Polyol  Safety Assessment;  Stability of Cyclopentane Pre-blended Polyols;  Flammability Testing;  Storage;  Conversion of Cyclopentane Preblending Facility;  Transportation Requirements;  Conversion of Foam Workshops Using Cyclopentane Pre- blended Polyols 4

Safety Assessment  Assessment conducted by Nanjing Forest University;  Stability of cyclopentane pre-blended polyols;  Flammability;  Transportation;  Chinese guidelines for foam manufacturers using of cyclopentane pre-blended polyols;  Set up of foam producer facility converting to hydrocarbon pre-blended polyols;  Stability of production; and  Quality of foam produced. 5

Stability of Cyclopentane Pre-blended Polyol 6  Stability of cyclopentane in the polyols is essential for maintaining the contents of cyclopentane within the polyols and the quality of final foam products;  16 formulations for cyclopentane provided by 6 Chinese polyol suppliers;  Samples with two different contents of cyclopentane: 100:13 and 100:15 (mass ratio) stored for 48 hours and at temperature ranging from -5 o c to 25 o C, tested for stability and separation (stratification);  Conclusion: Most samples demonstrated good stability. Only a few samples showed stratification at low temperature;  Findings consistent with previous study conducted by Huntsman.

Flammability Testing 7  Products with flash point below 45 o C are classified as flammable;  Flash point is determined as the temperature of product at which vapor released is instantly ignited by a flame. (Different test methods provide different results);  Flash point was tested by two methods (open method: GB/T ) and closed method (GB/T ) for formulation ranging from 100:5 to 100:15 (mass ratios);  Conclusion: Formulations with mass ratios of 100:13 and higher are found flammable by the open flash point method. Formulations with all mass ratios are found flammable by the closed flash point method.

Storage 8  Vapor pressure determines the requirements of storage of flammable materials;  Vapor pressure was determined for 100:15 formulation at temperature ranging from 30 o C – 60 o C;  Vapor pressure was determined through the test method: GB/T : Dangerous Goods Test Method for Vapor Pressure of Flammable Materials;  Conclusions:  Highest vapor pressure was kPa (i.e., tanks and drums must withstand pressure of at least 200 kPa); and  Proposed minimum thickness of steel tanks and drums of 1.22 mm.

Conversion of Cyclopentane Pre- blending Facility at System House 9  New Equipment Needed:  Cyclopentane storage tank and pump;  Tanks and pumps for dry polyols;  Cyclopentane and polyol pre-mixing unit;  Tank and pumps for cyclopentane pre-blended polyols;  Filling equipment for cyclopentane pre-blended polyols;  Safety Measures:  Electrical installation consistent with Chinese area classifications: Chinese Class A Workshop;  Gas detectors and control panel;  Standby diesel generator;  Fire prevention and fire extinguishers;  Ventilation;  Safety requirements for cyclopentane storage tank and piping;  Separate different areas of the factory.

Conversion Costs of System House EquipmentApproved Cost (US$) Actual Cost (US$) Pre-mix machine and supporting equipment 120,000154,000 CP storage and pump50,00059,500 Auto packaging unit40,00032,077 Safety equipment120,000146,493 Trial10,000 Training10,000 Contingency35,000 Total385,000412,070 10

Transportation Requirements  Formulated polyols pre-blended with cyclopentane is classified as Grade II flammable liquid;  Personnel in charge must pass an examination of transportation authorities;  Vehicles, loading and off-loading equipment must meet the requirements for transportation of Dangerous Goods;  Limitations on transporting other chemicals with flammable liquids. 11

Conversion of Foam Workshops Using Cyclopentane Pre-blended Polyols  Storage of pre-blended polyols in a separate room designed for storage of flammable liquid;  Foaming area: Safety requirements based on the specific situations;  Standard safety measures:  Electrical installations meeting Chinese requirements for Grade II flammable liquid;  Ventilation;  Gas detectors and control panel;  Back-up power supply;  Nitrogen for blanketing;  Piping from drums in the storage area to foaming equipment;  Cost depending on actual situations. 12

Cost Indications for Foam Manufactures Using Cyclopentane (US$’000s) 13 Equipment Item HC with Storage tank & Pre- mixer HC with Pre-mixer (HC supplied in drums) HC supplied in pre- blended polyols Cyclopentane storage tank, pumps and piping 30 – 5000 Pre-mixer tank including static mixer 120 – – 900 Formulated polyol storage tank and pump, day tank 20 – Retrofit of foam* dispensers (per unit) 100 – 120** 30 – Safety equipment – Trials, Tech Assistance, training & safety audit 3020 – Total420 – – *Cost could be lower if supplied by local engineering companies. ** Assuming two foaming units

Cost Indications for Foam Manufactures Using Cyclopentane (US$’000s) 14 Equipment Item HC with Storage tank & Pre- mixer HC with Pre-mixer (HC supplied in drums) HC supplied in pre- blended polyols Range420 – – Mid point Contingency (10%) Total

Incremental Operating Costs 15 ApprovedUnit Price ($/kg) HCFC-141b Formulation Cyclo-Pentane Formulation Polyol (w/o blowing agent) % HCFC-141b % Cyclo-Pentane % MDI %135.60% Foam Usage Foam Price ($/unit) ActualUnit Price ($/kg) HCFC-141b Formulation Cyclo-Pentane Formulation Polyol (w/o blowing agent) % HCFC-141b % Cyclo-Pentane % MDI %144.60% Foam Usage Foam Price ($/unit)

Conclusions  Stability – Cyclo-pentane pre-blended polyol demonstrates good stability;  Flammability – Formulations (polyol:blowing agent) with mass ratios of 100:13 and higher are found flammable by the open flash point method;  Storage – Minimum thickness of steel drums should be 1.22 mm;  Conversion cost at system house - $410,000; and  Conversion cost at foam enterprises using cyclopentane pre-blended polyol is about $250,000 - $300,

Thank you 17