Backdraft Dampers. Backdraft Damper Training Application Backdraft dampers allow air to flow in one direction only and prevent unwanted (hot/cold outside.

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

Fire Behaviour Ventilation. Aim To provide students with information to give them an understanding of the behaviour of fire.
Packaged HVAC Equipment
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Series L Air conditioners for Laboratories.
Chapter 12 HVAC Controls Pneumatic Control Systems • Air Compressor Stations • Transmitters and Controllers • Pneumatic Thermostats • Auxiliary Components.
Energy Efficient Steam Systems
Trane Voyager™ rooftop units
Fan Coil Unit Product Line-up. FCU Home Application Show.
Carbon Dioxide Systems 1.Carbon dioxide properties 2.Storage 3.Uses 4.Limitations 5.Types of systems 6.Local Application 7.Total Flood.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
NFPA 96 and Building Code Requirements for Commercial Kitchen Hood Systems Presentation for the Sevier County Fire Code and Building Code Officials Presented.
Basic Refrigeration Cycle
Components of HVAC System
Fan Selection Criteria and Efficiency
Introduction Enthalpy Wheel
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Engineered Products Make-Up Air for Heating and Cooling.
The Application of Vertically-Mounted Jet Fans in Ventilation Shafts for a Rail Overbuild Richard Ray, Mark Gilbey and Praveen Kumar PB Americas, Inc.
WELCOME FROM Ireland. The History of Evaporative Cooling Evaporative cooling is the oldest form of air conditioning ever used The ancient Greeks used.
EARLIER KITCHENS PRESENT DAY KITCHEN Common misconceptions of kitchen ventilation. In a commercial kitchen the prime concern of the owners, designers,
Engineer Presentation
Management training Jumeirah beach residence sector 3 Presented by November 15 th 2006.
Passive Cooling. Natural Ventilation Air Cooling Shades.
Buildings and Structures 2 Natural and Mechanical Ventilation.
HCS Series Screw Compressor Packages. 2 HCS Series.
Refrigeration and Cooling Principles for Potato Storages
COMMERCIAL REFRIGERATION
Control Damper Products Manual Balancing Dampers
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
Local Exhaust Ventilation
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
VENTING AND COMBUSTION AIR
PLENUM FANS Terminology, History, Testing, Application and Trends AMCA International Technical Seminar 2009 Presented by: John Cermak, Acme Engineering.
Industrial Acoustic Sound Enclosures FanAir Company designs and builds Acoustic Sound Enclosures Engineered to each specific application to control noise.
SOLAR CHILL SOUTHWEST SOLAR PUMP POWER IN FAN MOTOR PAD MEDIA PUMP BOARD.
Mounting Direction Water Cooler Best solution OK Risk of air bubbles in the system Heatsink Water channels Inlet Outlet.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Energy Performance Certificates
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
HVAC523 Circulator Pumps.
The International Authority on Air System Components Fan Performance Mark Stevens Director of Laboratory Services AMCA International.
Constant Volume Regulators
Single-Point Zoning Damper Choices
Refrigeration and Cooling Principles for Potato Storages Roger Brook Professor and Extension Engineer Agricultural Engineering Department Michigan State.
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Aztec Sensible Cooling System  Series ASC 1A01  Indirect Cooler –No direct contact of water into the supply air –Stainless steel cooling tower –Fill.
HEATING AND COOLING SYSTEMS
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
VENTILATION AND FENESTRATION
We are one of the accredited manufacturers and suppliers of Accoustic Enclosure and Sound Proofing in northern part of India under brand Name of "DDSTHA".
VALVES IN PIPE LINES.
FRP Industrial Dampers
Cooling and Ventilation Systems
Maria’s Restaurant Chapter 1 Section 4
Maria’s Restaurant Chapter 3 Section 13
HOW SAL 35 - Linear diffuser
Air Distribution Control
Placement Considerations
Voyager II and III – Energy Recovery Modules
VENTILATION NOISE.
CHAPTER 3 VENTILATION.
MZC Multizone.
Humidity Control Applications Flakt Dryers
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
FBE03: Building Construction & Science
Liebert DSE High efficiency thermal management
Presentation transcript:

Backdraft Dampers

Backdraft Damper Training Application Backdraft dampers allow air to flow in one direction only and prevent unwanted (hot/cold outside air, wind, etc.) from “back-drafting” into the building. They only install in ducts, at walls, or in roofs and open automatically when air flows in the intended direction and automatically close when there is no air pressure or when airflow is in the opposite direction. Basic Functions Intake/Exhaust Barometric/Pressure Relief

Backdraft Damper Training Intake Intake backdraft dampers allow supply airflow into a building while preventing conditioned air from escaping when the fan is off. Typical Applications Intake Air Duct - Wall or plenum mounted Intake side of rooftop evaporative cooler (requires counterbalance)

Backdraft Damper Training Exhaust Exhaust backdraft dampers allow air to automatically exit the building and prevent outside air from entering the building. Typical Applications In tandem with wall mounted exhaust fan. Exhaust air duct - wall or plenum mounted Roof top power ventilator Rooftop gravity ventilator Wall Mounted Exhaust Fan Backdraft Damper Roof Top Power Ventilator

Backdraft Damper Training Barometric Barometric relief dampers open automatically under low velocity conditions - including natural airflow - and close automatically to prevent reverse airflow. Typical Applications Rooftop gravity ventilator Wall mounted relief (no duct or fan) Backdraft Damper Roof Top Gravity Ventilator

Backdraft Damper Training Pressure Relief Pressure relief dampers use counterbalance weights to maintain a relatively constant upstream pressure, they open automatically at higher pressures and close automatically when pressures drop. Typical Applications Duct or plenum relief Room relief

Backdraft Damper Training AMCA 500D Test Requirements Test Samples Pressure drop: 12x12, 12x48, 48x12, 24x24, 36x36 Pressure Drop Ducted Inlet and Outlet - AMCA 5.3 Lowest Pressure Drop Ducted Inlet Only - AMCA 5.2 Plenum Mount - AMCA 5.5 (Highest Pressure Drop) AMCA 5.3 – Ducted Inlet & Outlet AMCA 5.2 Ducted Inlet AMCA 5.5 – Plenum Mount

Backdraft Damper Training Design Basics and Typical Application Light Duty Most common type and widely used for intake, exhaust, barometric, and pressure relief applications where air pressures and velocities are low (≤ 2 in wg. & 1250 fpm). Medium Duty Typically used for intake, exhaust, and pressure relief when pressure or velocity exceeds the light duty range (>2 in wg. & 1250 fpm, but ≤3 in. wg. And 2500 fpm. Industrial Employed when the temperature, pressure, or velocity exceed standard commercial damper limits. Units are typically flange mounted directly to the duct or fan housing.

Backdraft Damper Training Light Duty Backdraft Dampers Applications –BD-50 Gravity Intake and Exhaust Prop-Fan Exhaust Roof Top Power Ventilator –BD-51 Intake or Exhaust – where damper blade noise is a concern –BD-52 Evaporative Cooler – Discharge Side (down-flow only) –BD-54 Pressure Relief Mounting Arrangements –Vertical Mount –Horizontal Mount Up-flow Down-flow ( BD-52 Only ) Caution –Multiple Sections –Maximum Velocity & Pressure Limits –No Exact Pressure Settings Vertical MountHorizontal Mount Adjustable Counterbalance Weight Tie-Bar Integral Counterbalance Weight Channel Frame

Backdraft Damper Training Medium Duty Backdraft Dampers Applications –BD-60 Fan Exhaust - Duct or Plenum Mount –BD-64 Pressure Relief - Higher velocity Mounting Arrangements –Vertical Mount –Horizontal Mount Up-flow only Caution –Low-end velocity and pressure limits –No Exact Pressure Settings –Retarding Counterbalance Design Only - No assist to Open Vertical MountHorizontal Mount Hat-Channel Frame Concealed Linkage Adjustable Counterbalance Weight

Backdraft Damper Training Industrial Backdraft Dampers Applications –BD-84 Fan Exhaust - duct or plenum mount Mounting Arrangements –Vertical Mount only Caution –Low-end velocity and pressure limits –No Exact Pressure Settings –Assist to Open Counterbalance design only Channel Frame Concealed Linkage Adjustable Counterbalance Weight

Backdraft Damper Training Options & Accessories Flange Frame For flush mounting to equipment/wall Intake or discharge Sleeve 304 Stainless Steel Construction Electric Actuator (BD-58 Only)

Backdraft Damper Training THANK YOU!