Commercial Smart Plug Power Strips Proposal: UES Small Saver Josh Rushton Regional Technical Forum February 18, 2015.

Slides:



Advertisements
Similar presentations
Deemed Measure Reviews: 1.) LED Holiday Lights, 2.) Multifamily Low-Rise New Construction, and 3.) Room Air Conditioners March 1 st, 2011 Regional Technical.
Advertisements

Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
Residential Single Family Clothes Washer UES Measure Update Christian Douglass Regional Technical Forum February 18, 2015.
Commercial UES: Smart Plug Power Strips Josh Rushton Regional Technical Forum March 17, 2015.
Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Variable Frequency Drives (VFDs) for Potato/Onion Shed Fans UES Measure Update Regional Technical Forum April 23, 2014.
ENERGY STAR ®. Earning the ENERGY STAR ® means a product meets strict energy efficiency guidelines set by the US Environmental Protection Agency and the.
Commercial Tank Water Heaters Out-of-Compliance (OOC) UES Measure Recommendation Regional Technical Forum November 19, 2013.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
LED Case Lighting With and Without Motion Sensors Michele Friedrich – Sr. Engineer PECI 1/5/2010.
Commercial Showerhead UES Measure Update Regional Technical Forum Staff Update June 18, 2013.
Heat Pump Water Heater (HPWH) Subcommittee Christian Douglass Regional Technical Forum June 18, 2015.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Advanced Power Strips (APS) Planning UES Measure Proposal Regional Technical Forum August 20, 2013.
Power Management and Other Energy-Efficiency Strategies for Plug-Load Equipment May 12, 2006 Presented by: Carol Sabo, PA Consulting Group Tom Bolioli.
Heat Pump Water Heaters: Tier 2 – Ducted Interior Installations Provisional UES Proposal Regional Technical Forum February 14 th, 2012.
Residential UES: Smart Plug Power Strips Josh Rushton Regional Technical Forum Aug 18, 2015.
Plans to bring Out-of-Compliance UES Measures back into Compliance: 1. Agricultural Irrigation Hardware UES 2. Agricultural Motors UES Regional Technical.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Advanced Power Strips (APS) Planning UES Measure Proposal Measure Proposal Presentation to the.
Capacity Impacts of Energy Efficiency What We Know and What We Don’t Know March 11, 2014.
Provisional Protocol and Research Plan: Non-Residential Lighting Retrofits Nonresidential Lighting Subcommittee November 6, 2014.
Non-Residential Network Computer Power Management UES Measure Update Regional Technical Forum July 16, 2013.
Pre-Rinse Spray Valve Small Saver UES Measures Regional Technical Forum September 17, 2013.
Julianna Ferrari. Standby energy drain accounts for anywhere from 5 to 10 percent of an average home's annual power usage. Around $4 billion in wasted.
Residential UES: Smart Plug Power Strips Josh Rushton Regional Technical Forum Aug 18, 2015.
Residential Behavior Programs RTF Subcommittee Ryan Firestone September 17, 2015.
Agricultural Irrigation Pump Variable Frequency Drive Provisional Standard Protocol Proposal Regional Technical Forum April 16, 2013.
COMP 2923 A2 Basic Green IT Audit Danny Silver JSOCS, Acadia University.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
Commercial Showerhead UES Measure Update Regional Technical Forum Staff Update June 18, 2013.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Smart Power Strips in Commercial Office Applications RTF October 4, 2011.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
RTF Staff, Subcommittee and Work Updates November 1, 2011.
Anti-Sweat Heater Control Small Saver UES Measure Regional Technical Forum September 17, 2013.
N ETWORK PC P OWER M ANAGEMENT June 28, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
EER Analysis Results Regional Technical Forum March 18, 2014.
Commercial Showerhead UES Measure Update Regional Technical Forum April 16, 2013.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
LOW AND NO COST WAYS TO SAVE ENERGY!!! ROGER PERRY Facilities Manager Phillip Merrill Environmental Center Annapolis, MD.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Extension of Provisionally Deemed Smart Strip in Commercial Applications RTF March 2,
RTF Management Update Jennifer Anziano Regional Technical Forum February 18, 2015.
Via Christi Regional Medical Center Wichita, KS Lindy Pope September 14, 2007 Electricity Reduction.
Advanced Power Strips IR-Sensing, Home Entertainment Provisional UES Josh Rushton Research and Evaluation Subcommittee September 22, 2015.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum March 18, 2014.
Network PC Management Slides for RTF March 1, 2011.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Smart Power Strips in Commercial Office Applications RTF August 30, 2011.
UES Measure: Commercial – Traffic Signal LED’s Commercial – Traffic Signal LED’s Proposal to Change Status from “Under Review” to “Active” Regional Technical.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
Non-Residential Network Computer Power Management Christian Douglass Regional Technical Forum January 21, 2016.
Non-Proven Residential Duct Sealing Measures: Research Strategy Josh Rushton and Adam Hadley Research and Evaluation Subcommittee October 7, 2015.
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
Implementer’s Group December Meeting Debrief and Upcoming Meeting Prep January 6, 2015.
Commercial Efficient Tank Water Heater UES Measure Update Regional Technical Forum December 17, 2013.
RTF Staff, Subcommittee and Work Updates February 14, 2012 IRTF.
Residential Behavior-based Programs Measure Development Update Ryan Firestone Regional Technical Forum March 15, 2016.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Vampire power. contents  Introduction  Devices which use standby power  Tips to reduce vampire power  Smart Power Strip  Conclusion.
RTF Delivery Verification Guidance Batch 3 Jennifer Light Regional Technical Forum November 10, 2015.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Energy Efficient Appliances and Plug Loads
ASHRAE, California Title 24, NEC
GREEN CERTIFICATION Take Charge Go GREEN!
Presentation transcript:

Commercial Smart Plug Power Strips Proposal: UES Small Saver Josh Rushton Regional Technical Forum February 18, 2015

Presentation Outline Objective: Update to Commercial Smart Power Strips measure (recommend UES Small Saver) History Overview Savings Cost Proposal 2

History April, 2009: RTF “provisionally deems” smart strip UES (100 kWh/yr). October, 2011: Based largely on BPA Ross complex data, RTF approves load sensing smart strip in commercial office applications (proven UES 100 kWh/yr) Past RTF discussions noted that the measure has a lot of potential but hasn’t really taken off. This is still the case. 3

Measure Overview Sector:Commercial Measure name:Smart Plug Power Strips Baseline:Pre-conditions Applicability: Office space setting Load-sensing, motion-sensing, and timer-controlled power strips Must have at least one controlled device CurrentProposed Category:ProvenSmall Saver Status:ActiveActive Sunset Date: 03 / 31 / / 31 / 2016 Annual Savings:100 kWh118 kWh Measure life: 4 years 4 years B/C Ratio:

Measure Overview 5 Load-sensing smart strips Powers down switched outlets when idle power level detected in “master” device Typical set-up looks for PC sleep mode Set-up: Enable PC sleep mode, set potentiometer to detect sleep mode power level Timer-controlled smart strips Powers down switched outlets at pre-determined times of day Set-up: Program off-hours Motion-sensing smart strips Powers down switched outlets when no motion has been detected for X minutes. Set-up: Position motion sensor New additions in proposed measure Included in current measure

Measure Overview Common set-ups Workstation (load sensor, motion sensor, timer) – Switched: Monitors, desk lamps, printers, personal space heaters, speakers, tiny decorative waterfalls, … – Not switched: CPU, other sensitive devices – For load sensors, primary monitor often plugged into “master” outlet (not switched) Copy room (timer) – Copier, printer, scanner/fax machine, … Break room/kitchen (timer) – Coffee maker, water cooler, … 6

Savings Depends on… – Mix of controlled devices (we know something about this) – How often spaces/devices are idle; whether idle devices are powered down in base case (know less about this) Hard to measure directly. Pre-/post- metering may be complicated by… – Seasonal lighting and heating – HR policies limiting electronic devices (researchers need to sample a lot of different businesses) 7

Savings Control Type BuildingBuilding Type ReferenceSample sizeAnnual energy savings Load Sensor WW LogisticsCommercial[IDL, 2012]88 APS (94 FTE) 19% of plug load; 160 kWh/APS 1 Ross BuildingGovernment[BPA, 2011]45 APS (all at workstations) 29% of affected load; 130 kWh/APS 2 VA CenterGovernment[NREL, 2012]12 APS10% of affected load R&M CHGovernment[NREL, 2012]12 APS23% of affected load 3 Motion Sensor Land RecordsGovernment[IDL, 2012] 33 APS (31 FTE) 22% of plug load; 75 kWh/APS 4 Timer WJ Greene Bldg.Government[NREL, 2012]12 APS52% of affected load 5 EA Garmatz CHGovernment[NREL, 2012]12 APS43% of affected load 3 JBPHH-A4Military Office[NREL, 2014]100 APS (90 FTE) 28% of plug load; 110 kWh/APS 3 1 Figures approximate based on published tables. 2 Includes high savings due to one outlier and zero savings due to user-disabled units; median savings 80 kWh. 3 Approximately two thirds of savings due to printers/copiers. 4 Report notes low number of auxiliary plug loads in this office suite. 5 Nearly 80% of savings due to kitchen equipment. 8

Why is small saver okay? Roadmap Section 2: “The RTF may determine that the likely savings from a measure are too small to warrant the resources needed to meet the quality standards defined for Provisional or Proven measure. Such measures are categorized as Small Saver.” Puget: Not currently offering this measure Tacoma: Often suggest program participants but haven’t found much interest. Avista: Might offer next year, but haven’t offered for past two years BPA publics: Reported 3,929 commercial smart strips in 2013 (2014 tally not yet known). Not the highest-priority measure for ramp-up at this time At 100 kWh per unit per year, 10,000 units would be about 0.1aMW Reminder: Guidelines intend Small Savers to be included in evaluation (if certain threshold condition is met) 9

Cost ControlBrandModelOutletsCord length Protection rating Price 1, 2 Load Sensor Tripp LiteAV86G86 ft.1080 J$30 TrickleStar74 ft.2160 J $35 3 Take ChargeUTC8MS82 ft.2400 J$30 Smart Strip ft. 900 J$32 Motion Sensor WattStopperIDP ft. 740 J$80 TrickleStar74 ft.1080 J$40 Timer Tripp LiteTLP74TG74 ft.2100 J$36 TrickleStar84 ft. 720 J$30 None Tripp LiteTLP606B66 ft. 790 J$11 Tripp LiteSuper7B77 ft.2160 J$17 TrickleStar74 ft.2160 J $20 3 BelkinBE106 – 08R66 ft. 700 J$11 1 Except as noted, prices are from amazon.com (Feb. 4, 2015) and do not include shipping. 2 Prices may also be affected by factors such as product warrantee and current capacity (amps) that vary among models and are not recorded in the table. 3 Price from manufacturer web page (Feb. 4, 2015). 10 Average of these: $33.30

Cost Cost based on full purchase price (not just increment over standard power strip option) Does not include shipping expense 11 Purchase price (online retail, Feb, 2015)$33.29 Installation cost (10 minutes; $20/hr) $3.33 Total$36.62

Proposed Motion “I, ______________, move to approve the Commercial Smart Plug Power Strips measure as a Small Saver with a sunset date of March 31, 2017.” 12

Additional Slides 13

References [IDL, 2012] Acker, B., C. Duarte, K. Van Den Wymelenberg, Office Building Plug Load Profiles, Technical Report , University of Idaho Integrated Design Lab. [BPA, 2011] BPA, Smart Power Strip Energy Savings Evaluation (Ross Complex), aluation%20Rev1.doc [NREL, 2012] Metzger, I., D. Cutler, M. Sheppy, Plug-Load Control and Behavioral Change Research in GSA Office Buildings, NREL action [NREL, 2014] Sheppy, M., Metzger, I., D. Cutler, G. Holland, Reducing Plug Loads in Office Spaces Hawaii and Guam Technology Demonstration Project, NREL. 14

Tier What? NEEP’s terminology note NEEP working group recommends “tier 2” as industry lingo for APS that target active power down savings …and use “Activity Monitor Power Strip” with “active power down” savings as the customer-facing phrase Activity Monitor Power Strip (includes tier 2). Power strip looks for signs of activity in the room, and turns off outlets if none is detected. Use additional phrase “Active Power Down” when describing Tier 2 APS. Master-Controlled Power Strip. When a primary device (such as a computer or TV) is turned off by the use, the power strip automatically turns off (de-energizes) the controlled outlets. Masterless Power Strip. When all of the controlled devices are turned off, the power strip turns off power to those outlets completely, eliminating all of the vampire loads. Remote Switch Power Strip. Power strip can be turned off by the user via a remote switch. Timer Power Strip. 15

October 2014 RTF meeting Jerome: CLEAResult has been looking at other Technical Reference Manuals (TRMs) to see if they will be of help. I’ll let you know if we find anything. Davis: There have been proposals to do things with this, but nothing has materialized regionally. Danielle Walker (BPA): Yes. I’ll check whether BPA is on the uptake. Davis: In Vancouver there’s some trouble with the data. Grist: One question is what is connected to the power-strip that you're turning off – it can be anything from a computer to foot warmers. People added space heaters to the post-period versus what was there in the pre-. Eckman: Is there a recommendation to bring it back as an alternative measure type – a Small Saver – pending no data? – Rosolie: I move to extend the sunset date to March 31, (Koran: Second) Davis: The sample size you’d need given the variance is spectacular. Brad Acker: What’s the status of the available research? – Grist: We have nothing new, although BPA and CLEAResult are looking into it. – Acker: I have a 2011 paper. 16