Scott 4.5 Introductory SCBA.

Slides:



Advertisements
Similar presentations
QUARTERLY SCBA Practice Part 1
Advertisements

USING THE OXYACETYLENE CUTTING TORCH
SKA-Pak Plus Mobile Air Cart Con-Space Link
Using Gas Welding Equipment
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Blackwood Fire Company SCBA Refresher. Regulations NJ PEOSH 12: Respiratory protection devices OSHA 29CFR Operating Guideline 7.2 Firefighter.
Properly Securing the SCBA in Stowage Bracket Clips 1. Insert SCBA into walk-away bracket clips, ensuring the stowage strap is not trapped within the bracket.
2 Fire Fighter Qualifications and Safety Skill Drills.
TESTING Dräger PSS 7000 Breathing Apparatus GENERAL TEST
Blackwood Fire Company IN-HOUSE SCBA REQUALIFICATION.
NFPA 1981 (2002 Edition) COMPLIANT LT MICHAEL BOEHLKE
Manlius Fire Department Annual SCBA & RIT Pak Familiarization Drill
SFFMA Training Objectives: –
UNIT: Oxy-Fuel Welding, Brazing, Cutting and Heating LESSON: OXY-ACETYLENE EQUIPMENT SAFETY Standard B7.2 – Know how to properly set up, adjust, shut down.
Draeger BG-4 Self Contained Breathing Apparatus
1 FUEL SYSTEM SERVICE ENGINE CLEAN FUEL TOOL MODEL RX 777.
Oxygen Administration R/C MERT Medic Assistant Lesson V.
General Rules Compressed gases and cylinders must be properly stored, transported and used to prevent injury and accidents. Compressed gases and cylinders.
Job Performance Requirement 7-13 Servicing an SCBA Cylinder Using a Cascade System.
Intermediate SFFMA Objectives: – Hrs received.
SAFE PROPANE TORCH USAGE
VRFA 2011 Annual Respiratory Training. Objectives Hazard Recognition Understand current components Review daily, weekly, and after use inspections Review.
Passive Leak Detection Operation Training October 2014.
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Using the Oxy-Acetylene Cutting Torch Alisa Colli AgEd 410 Fall 1999.
Sava air bags. The new equipment Air Bags Kevlar reinforcing w/ thick, multi-layer rubber shell 24” x 24” positive grip surface w/ safety straps Max load:
UNIT: Oxy-Acetylene Welding, Brazing, Cutting and Heating
OXY-ACETYLENE TORCHES Protect your head and eyes by wearing proper welding goggles or face shields equipped with a minimum shade 5 lens. Protect your.
Agricultural Science II.  Define the chapter terms on an exam with 90% accuracy.  Describe the proper/safe way to turn the oxyacetylene rig on and off.
Terms and Definitions Base Metal: Metal to be welded Fusion Welding: process that joins metals by heating them to a melting point and allowing them to.
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
Brake System Diagnosis and Repair
F LOTEC Training Presentation for Authorized Repair Centers This presentation is designed to supplement M-Service Manual InGage Regulator.doc Flotec, Inc.
S.C.B.A. MAINTENANCE By: Lt. Eric Miller Parksville Fire Department.
OXYTRONIC 600 CONTINOUS FLOW NITROX SYSTEM
FAST Rescue Air Pack F.A.S.T. Ops. F.A.S.T. Pack Operations  Goal To facilitate the safe removal of a downed firefighter from a hostile environment 
Station 31 & Station 35 Procedures for fill station with booster pump.
Wellington County Fire Training SCBA Presentation
SCBA CLEANING Monthly and after use. Use mild detergent (dish soap) or Confidence Plus mixed at ½ ounce per gallon of water. Use a brush if necessary.
Oxy Fuel Welding Basic Setup & Use
Los Alamos Fire Department
Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK.
1 Fire Fighter Qualifications and Safety Skill Drills 2.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
PERSONAL PROTECTIVE EQUIPMENT State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
FFII Module A Hillcrest Fire Department © 2001
VRFA ANNUAL RESPIRTORY PROTECTION. THE ADMINISTRATOR.
Valves.
Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.
Donning and Doffing SCBA Firefighter I. Copyright © Texas Education Agency All rights reserved. Images and other multimedia content used with permission.
1 RESPIRATORY PROTECTION TRAINING RESPIRATORY PROTECTION TRAINING Information from OSHA Standard And SCOTT 2.2 SCBA Manual Lesson prepared by.
Fire Fighter Safety SCBA CHANGE/REFILL
AfterSalesTraining Welcome to AfterSalesTraining.
The Welding/Cutting Torch Objective 25.0 Demonstrate proper procedures for oxyacetylene processes.
Job Performance Requirement 7-1 Donning SCBA  Over the Head Method.
Chapter 18 The Clutch System.
OBJECTIVES Discuss the various methods of loosening the brake bleeder valve. Discuss the need for brake bleeding. Describe the manual bleeding procedure.
Oxyacetylene Start Up/Shut Down Procedure
Job Performance Requirement 7-11
Super Flow 450 Regulator.
T-6B On-Board Oxygen Generation System (OBOGS)
Shutting Down the Cutting Outfit
Brake System Diagnosis and Repair
2 Fire Fighter Safety.
2 Fire Fighter Safety.
Filling of SAPPHIRE 25 & 42 Bar Systems (TFPP Hardware)
Oxygen Acetylene Cutting Torch
Compressor Operating Instructions
T-6B On-Board Oxygen Generation System (OBOGS)
Super Flow 455 Stainless Regulator
Presentation transcript:

Scott 4.5 Introductory SCBA

Parts of the Airpack Harness Face piece Cylinder Regulator Integrated PASS.

Face Piece AV 3000 Latex free Four point tightening Increased visibility.

Cylinder Carbon Wrapped Lighter weight Smaller bottle Increased mobility Max pressure 4500 psi.

Regulator Air supply connection By-pass valve Clip connection to face piece Button for positive pressure supply.

Integrated PASS Connected to harness Manual alarm button Alarm reset Remote air supply gauge Lighted area during alarm activation.

Face piece & Regulator Assembled regulator connects with a ¼ turn If wearing the mask, by-pass valve pointed up, place into slot on face piece then turn a ¼ turn counter-clockwise.

Activating the Air-Pak 4.5 Open the turn valve on the cylinder If air bleeds out of the regulator: Press the positive pressure supply button, or Turn the by-pass valve off of purge.

Turning off the Integrated PASS Turn the cylinder completely off; Open the by-pass valve until all residual pressure is bled off; Depress the reset alarm button twice quickly; The pack will chirp and make a distinct sound to signify the PASS is deactivated.

Changing a Cylinder Turn the cylinder off; Completely bleed the remaining air by opening the by-pass valve; Unscrew the cylinder from the harness; Unlock the cylinder strap; Depress the cylinder release button; Slide the cylinder to be changed out;

Changing a Cylinder Slide a full cylinder back through the cylinder strap until it clicks in; Screw the cylinder on; Secure the cylinder strap; Open the cylinder and assure that the remote gauge reading is within 100 psi of the cylinder psi reading.

Weekly Inspection Inspect SCBA for cleanliness; Inspect Harness for wear; Ensure the cylinder gauge reads above 4200 psi; Completely open the cylinder; Allow SCBA to remain motionless; PASS device should activate within 45 seconds;

Weekly Inspection Confirm SCBA hoses and cylinder connection has no leaks; Open and close by-pass valve to ensure operation; Close cylinder; Bleed off residual pressure by slowly opening by-pass valve;

Weekly Inspection Observe remote gauge as pressure drops; Warning alarm should activate between 900 and 100 psi; Ensure straps are extended; Store SCBA in proper place with regulator in holder.