Installation Simplified… by April 2006. Cell Phones  As a courtesy to all, please set your cell phones to silent.  There will be a break to return phone.

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

Advanced HAI Lighting Control (HLC)
IPS of Boston Checks On Demand! ® Welcome! To navigate this presentation, first click in this window, then use the arrow keys on your keyboard. Welcome!
SCW9057 Key Features/Benefits
Quick Installation Guide for Hurricane8800P
XT30/XT50 Basic Training System Overview
Welcome to the Award Winning Easiest to Use & Most Advanced View, Manage, and Control Security, Access Control, Video, Energy & Lighting Systems, & Critical.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Integrated Technology!
Copyright, 2006: Invisible Service Technicians, LLC Invisible Service Technicians, LLC Invisible Service Technician Monitor Activation Process: IST MaintSelectionV3.php.
ZXM10 EISU Training.
ModCon® 75 Controller.
DSL-2730B, DSL-2740B, DSL-2750B.
New Products From September Whole Home Solutions.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
WebStat™ Programming and Configuration of Thermostats.
HAI “Integrated Automation” Advanced Programming.
Total HVAC Control from anywhere Easy control that can save a fortune
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Energy Management by January Our Company and Market  Our mission: Coordinating security, temperature, and lighting for comfort, convenience and.
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
LogTag Training January 2015
X-Media V2.0 Healthcare Training Jayex Technology Limited X-Media V2.0 March 2010 v
WELCOME A Security Masterpiece. Control Panel Line-up Max Zones Basic Zones Max Zones Basic Zones n 1725EX14 6 (4 + 2) n 1728EX15 7 (5 + 2) n 1738EX16.
HAI Lighting Control Options UPB Technology Presentation Advance Information January, 2004.
DAP-1520 FAQ’s Wireless AC750 Dual Band Range Extender.
EVOLUTION® Hands-On Demo This guide is meant to help lead a hands-on demo or presentation. The items listed are a suggestion for things to review, please.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
April 2004 page 1 Confidential and propietary CentraLine Portfolio c l o s e t o y o u.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
The Comfort System Product Presentation The Intelligent Home System.
Training.
CCNA 2 v3.1 Module 2.
Copyright © 2013 FingerTec Worldwide Sdn.Bhd. All rights reserved.
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
Step 1 - Start your PC and place your Windows XP CD in your CD/DVD- ROM drive. Your PC should automatically detect the CD and you will get a message saying.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
1 INTRUSION ALARM TECHNOLOGY KEYPADS (CONTROL UNITS)
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
DWR-113 FAQ’s 3G WiFi Router.
The Vision of a Leader Rapid Eye Plus Technical Training.
Configuring the MagicInfo Pro Display
SMART Response Initial Set-up: Windows PC Teacher and Class Set-up Creating a Quiz, Test, or Survey Delivering an Assessment Reports Additional Question.
Basic Navigation in SAP For the Windows Graphical User Interface (GUI) Click your mouse anywhere or select “Page Down” to scroll through the pages.
TL250-Internet Communicator. Compatibility Specifications VDC current draw 12 VDC input voltage Size: 3.25” × 5.25” (8.3 × 13.3)cm Operating.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Home Media Network Hard Drive Training for Update to 2.0 By Erik Collett Revised for Firmware Update.
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
NMU Voic Welcome to. This presentation will walk you through the setup and use of the NMU Voic system. Follow the step by step instructions.
DSL-2544N Dual Band Wireless N600 Gigabit ADSL2+ Modem Router
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
Sales and Business Development. What is Home Automation?  An automated home brings together security, fire, lighting, temperature control, audio, home.
Floor Plans View zone locations on up to 32 floor plans View & import floor plans Open zones flash Displays system status.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
VIP Workshop Series Russound & OmniProII Integration April, 2005.
Service Section Technical Training December 2005.
Technical Introduction April Internal usage only 1 General Features  Self contained batch solution for small, standalone applications.  All functionality.
Purchase Orders Notes:.
3M Partners and Suppliers Click to edit Master title style USER GUIDE Supplier eInvoicing USER GUIDE The 3M beX environment: Day-to-day use.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Hardware Configuration Guide Configuring Dongles and Creating Barcodes for Devices Used with VSC.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Residential Security, Access Control, and Surveillance Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Presentation 5 – The HAI Omni II Controller.
The first change to your project files that is needed is to change the device to the correct FPGA. This is done by going to the Assignments tab on the.
GEM-P1632 Hybrid Control Communicator
Total HVAC Control from anywhere Easy control that can save a fortune
Presentation transcript:

Installation Simplified… by April 2006

Cell Phones  As a courtesy to all, please set your cell phones to silent.  There will be a break to return phone calls

Installation

System Controller: Omni LT

System Controller: Omni IIe / Pro II

Lumina and Lumina Pro

Power & Ground  Ground to good earth ground with thick wire for surge/lightning protection.  Connect transformer (use a good one with self reset capabilities)  Omni IIe and Pro II use 24 volt transformers  Omni LT uses 16 volt transformer  40 VA transformer  Lumina systems include a transformer and battery

Phone Line Seizure  RJ31X Jack  Phone Access  Local  Remote  Central Station  Computer Access Bend tab up if necessary to ensure tight fit. RED GRAY GREEN GRAY BROWN

Security System Wiring  Door and window security contacts  Multiple contacts may be wired in series + Z1 - + Z2 - Normally Closed Normally Open Zones / Inputs

Z1 Normally Closed Zones / Inputs + - Window 1 Window 2 Window 3 Multiple Contacts On a Loop

Powered Devices  Motion Detectors  CO Detectors  Glass break + Z5 - +Aux- NC Pwr Note: Diagram shows a normally closed (NC) device. A normally open device can be used if the EOL is in parallel.

4 - Wire Smoke Detection Note for 4-wire smokes start on zone 5 (easier to wire)

2 - Wire Smoke Detection It is recommended NOT to use 2-wire smokes with sounders (too much power draw)

RJ-31X Telco Jack  Line seizure to dial out in emergency  Ability to use in house phones

HAI Consoles & Touchscreens

Address Each Console & Touchscreen Consoles: Push and hold 4 & up- arrow to get into console set up mode Touchscreens: Tap and hold HAI logo to get into Touchscreen set up mode

Powerline Interface  For Lighting and Appliance control  Do not plug into surge strip  HLC PIM plugs into Serial Port  X-10 plugs into X-10 jack

Serial Connection

Ethernet  Omni IIe, OmniPro II, Lumina, and Lumina Pro Controllers  Port 4369  128-bit AES (Advanced Encryption Standard)  Use DNS service for Dynamic IP if remote access desired

Omni IIe / Pro II Security Expanders 17A00 Expansion Enclosure 16 Zones and 16 voltage outputs 1 amp battery backed, monitored power supply – uses 24 V 40 VA transformer, 12 V battery Ideal for powering touchscreens Saves on homerun wiring Up to 8 on OmniPro II 10A06-1 Hardwire Expander Mounts on Controller 16 Zones Up to 2 on Omni II, Pro II 22A00-1 OmniLT expansion module 16 Zones and 8 voltage outputs Mounts on OmniLT controller

Thermostat Installation HVAC wires communication connector Backlight jumpersensor

Thermostat Communication Earth GND 24VAC INPUT 12V GND SWITCH 12V GND AUXILIARY 12V GND A B CONSOLE INT GND EXT HORN 1 GND 2 3 GND 4 5 GND 6 7 GND 8 OUTPUTS GRN RED BRN GRY PHONE + Z9 - + Z Z Z Z Z Z Z Z1 - + Z2 - + Z3 - + Z4 - + Z5 - + Z6 - + Z7 - + Z8 - Address: Mode Off, Prog 3x, Fan, Location 00, Fan to Exit Option 3, Value 5 Filter Reminder Turn off Option 15, Value 60

Communications Wiring Detail  When used with HAI controller, connect black AND red communication wires from thermostat to black wire, then black wire to COM at the controller. Wire as shown. Omni IIe / Pro II / Lumina OmniLT

Address Thermostats  Be sure thermostats are working with HVAC system first (follow procedure in manual)  Enable thermostats in controller: Setup - Installer – Temperatures (9-#-5 on console) and set each thermostat to auto heat/cool  Press Prog Prog Prog Fan to get into set up mode  Location 0 is the Thermostat Address  Use ^ and v keys to change location value  Set thermostats to consecutive addresses (1, 2, 3…)  While you’re there, turn off internal scheduler (location 3 = 5)  Use keys while in set up to advance to next location  Press FAN to exit set up or just let it time out  Verify communications by Status-Temperature (6-5) on console – you should see the thermostat temperature  See the manual before you change anything else!!

Outdoor Temp Earth GND 24VAC INPUT 12V GND SWITCH 12V GND AUXILIARY 12V GND A B CONSOLE INT GND EXT HORN 1 GND 2 3 GND 4 5 GND 6 7 GND 8 OUTPUTS GRN RED BRN GRY PHONE + Z9 - + Z Z Z Z Z Z Z Z1 - + Z2 - + Z3 - + Z4 - + Z5 - + Z6 - + Z7 - + Z8 - 31A00-7 Outdoor Sensor No Direct Sunlight or Direct Rain Mount In a Covered Location ‘Weather resistant’ Not ‘Weather Proof’ Mount Vertically

Power Up  Follow power up procedure in manual.  Check connections for shorts, opens, wire whiskers, tightness, etc.  Plug in transformer (system should power up: AC power LED comes on and status light flashes)  Connect Battery  Consoles will beep during power up and until addresses are set.  Test all zones and devices!

Setup

The “Left half” and The “Right half” Set Up:  Names of Units, Zones, Buttons, Thermostats, Codes, etc.  Zone types, output types, thermostat types  Expansion boards and enclosures, wireless  Digital and voice dialers  Longitude, latitude & time zone, etc. Programming:  Where home automation is done, coordinating security, temperature and lighting  Front Light on When Front door is open if it’s after dark

PCAccess  Create programs in PCAccess  Review, edit delete, cut, paste, copy  Search for programs  Download to controller

Recommendation: Just Hit ‘Enter’ Security Stamp

Password Default Password: ‘Password’

Opening screen Open or create a New File

Creating a New File

Once a controller is selected the file data can not be converted to a different controller

All of data on this screen is for company records. It is NOT downloaded to the controller Just for your notes Customer Data

Setup Names/Voice: Zones Always Step 1 Note: Use Upper/Lower Case Note: Always Choose the voice descriptions when text is entered. It is an excellent habit! Hardware cheat sheet: Z= Main Control Board; EX1-1 = Expander 1, Input 1; EE1-1 = Expansion Enclosure 1, Input 1

Setup Names/Voice: Tab Key

Setup Names/Voice: Units HLC units are labeled on the right

1. HLC Configuration HOUSE CONTROLLER MASTER BEDROOM LIVING ROOM CONTROLLER DINING ROOM CONTROLLER LIVING ROOM SWITCHES DINING ROOM SWITCHES

Set up rooms with HLC  1: Living Room Controller  2: Chandelier  3: Sconces  4: Wall Wash  5: Lamps  6: Picture Spots  7:  8:  9: Den Room Controller  10: Lights  11: Cove  12: Lamps  13: Bar  14  15  16 House Controller  To Use HLC:  Rooms are set up in groups of 8 units  The first unit in a room is reserved for a room controller  The last unit can be used for a house controller  All you have to do is create the rooms and HLC does the rest

HLC Details  Standard HLC Configuration:  First unit in a group of 8 (1, 9, 17, 25, …) is reserved for Room Controller  Up to 7 loads (lights or appliances) per Room Controller  Up to 8 rooms per House Controller  OmniLT: 14 loads (2 rooms)  Omni IIe and Lumina: 56 loads (8 rooms)  OmniPro II and Lumina Pro: 217 loads (30 rooms)  Example: Omni Controller automatically links 1: Living Room Controller with loads 2 – 8, and 9: Den Room Controller with loads 10 – 16.  Homeowner can easily adjust scenes for the different rooms.  Up to 8 House Controllers can be added anywhere “on the eights” in the first 64 units (example: unused unit 8 and/or 16) and it will control the first 8 rooms (64 units).  Loads and buttons are still fully controllable (and programmable) in Omni

Setup Names/Voice: Buttons Note: Only use a ‘Button’ when the customer should have manual control of the routine. Use a flag for ‘hidden’ routines

Note: Naming users and assigning them individual codes makes reading the even logs easier and more informative. Setup Names/Voice: Codes

Setup Names/Voice: Thermostat

Displayed On Keypad Spoken over the phone or out the 2-way voice board Note: The text and voice do not have to relate to each other but it does reduce confusion ASCII Messages Sent / Received through the RS-232 serial port (ProLink) ^M=Carriage Return Setup Names/Voice: Messages

Serial Configuration Leave at 9600 Baud Confirm the Correct Port For Serial Connections: Code 1 in the software file MUST match Code 1 CURRENTLY in the controller. At default both are After 3 unsuccessful tries you are locked out. Pull the transformer and battery to power down the controller.

Network Configuration For Network Connections: Code 1 in the software file MUST match Code 1 CURRENTLY in the controller. At default both are After 3 unsuccessful tries you are locked out. Pull the transformer and battery to power down the controller. The Omni ProII uses a 10Base T connection Change via console, serial or modem Ethernet Options on the Console 9, Valid Code, 6,  (Scroll to Options) Must be read from the console

Modem Configuration Confirm the Correct Port Leave at Baud Modems should ‘auto discover’ LT = 300 Omni II = 9600 Pro II = 14.4K For Modem Connections: Code 1 in the software file MUST match Code 1 CURRENTLY in the controller. At default both are After 3 unsuccessful tries you are locked out. Pull the transformer and battery to power down the controller. Last 4 ones ‘1111’ is the access code

Command: Set Time Are we currently in Daylight Savings Time? Winter = No Summer = Yes

Show / Status

A/D Reading Show / Status / Zones Note: It is an excellent habit to always confirm hardware connections Omni II / Pro II – Standard (non-smoke) readings: 0 – 20 = High Side Ground Fault 21 – 35 = Trouble 36 – 80 = Low Side Ground Fault 81 – 110 = Trouble 111 – 136 = Closed 137 – 157 = End Of Line (Secure) 158 – 200 = Trouble 201 – 255 = Open

Show / Status / Units This option is based on the last known command to or from a load. Note: This can only be reliable information if 2-way devices are used Note: When 2-way devices are used the controller will automatically update the status. Remember to set the PLC Communication protocol correctly. Note: Double click a unit to go to the unit/command screen

Command / Units – Compose Note: This screen shot is for a Unit set for Compose. Based on how the PLC format is set the ‘Scene’ command will change to ‘Light Level’

Command / Units - Standard Note: Notice the ‘Light Level’ Option. ‘Ramp’ refers to ALC options. Off / On / Dim / Brighten: Perform the desired command for the time period, and then do the opposite.

Setup / Codes Code 1 is the users most powerful code. It is always a Master code and will always allow access via PC Access software. Never set user 1 to 0,0,0,0.

Number is spoken during ‘dialed’ voice notification for alarms. Setup / Dial

T = 2 Second Pause

Loss of Phone is considered a ‘trouble’ condition Setup / Arming Should Say Entry/ Exit and Perimeter Zone Type Chime All Lights On for Alarm Technically is ‘Force Arm’ Yes/No? Turn off when kids have access to the console

Setup / Miscellaneous - Settings Which light to flash in alarm? Speak alarms out the 2-way voice board A link is in the dealer section User: dealer PW: haidlr

Setup / Miscellaneous – Control Standard: X10, PCS, Lightolier in Compatibility Mode Extended: Leviton, ACT A10 Compose: Lightolier Compose UPB: for non HAI UPB products HLC: for HAI Lighting Control Products Include this house code in the All On/Off Command?

Setup / Miscellaneous – Clocks Time Clocks are used to compare against in programs. They are not time schedules.

Setup / Miscellaneous – DST

The 8 Outputs on the Main Control Board Setup / Installer - Control Set The UPB Network Address and Password

Setup / Installer - Zones This refers to the 17A00 zone expansion cabinet, NOT the 10A06 zone expander When Zone Resistors are turned off all zone inputs MUST be Normally Closed

Popular Zone Types Entry / Exit – Entry Exit Doors Perimeter – Windows and Entry Points that should instantly alarm Night Interior – Motion armed in Night / Away and Vacation Modes Away Interior – Same as a Night Interior but NOT armed in Night Mode 2X or 4X Entry Delay – Multiply the standard entry delay time Fire – 2 or 4 wire smoke detector Auxiliary – ONLY automation, no security function Outdoor Temperature – Temperature sensor, show on thermostats Temperature – Temperature sensor, do not show on thermostats Temperature Alarm – Temperature sensor, alarm when programmed High or Low settings are exceeded.

Always use Contact ID when available Setup / Installer - Communicator

Setup / Installer - Partitioning

Setup / Installer - Temperature

Setup / Installer - Miscellaneous Only relates to access to Installer menus on the console Only relates to access to modem call in

‘0’ will keep the controller from looking for a phone line. Don’t forget to return to 8 once the house has a phone line. Setup / Installer - Miscellaneous

Turning off sounder supervision does not turn the supervision current off

Setup / Installer - Expansion Module # refers to the jumper in the upper left corner. Defaults are 1 – 10A06 Expander 2 – ALC Board 3 – Serial Board OmniLink – HAI Programming Protocol ProLink – Custom written ASCII Messages Leave at 0!

Consoles  You can do all set up and programming from the console, using the menus.  Allows you to get the basics up and running quickly in the field.  Programs can be added, edited or deleted.  Search capability.

Congratulations! You know how to install, setup, and program HAI Omni-Family automation systems.

What are the next steps?  Align yourself with an HAI Distribution Partner  Purchase a system to install in your home or office  Complete training special forms  Get HAI Tri-Folds to present to your customers  Meet requirements to be listed on HAI web-site  Sign up for HAI lead programs  Sign Up for news from HAI  Become a Five Star Dealer  Resources  Sales & Marketing: HAI Territory Manager  Tech Support: x 5  Pricing: Distribution Partner

HAI Special Training Offers  Promo 11 Omni LT Package  Promo 14e Omni IIe Package  Promo 16 OmniPro II Package *Refer to training flyer for details and limitations