Presentation is loading. Please wait.

Presentation is loading. Please wait.

TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.

Similar presentations


Presentation on theme: "TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB."— Presentation transcript:

1 TECHNICAL TRAINING 2007

2 SMART COMMANDER

3 System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB RAM or Higher Hard Drive : 4G or higher for hard disk spaceHard Drive : 4G or higher for hard disk space OS : Windows 2000/XPOS : Windows 2000/XP Resolution : 1024 x 768Resolution : 1024 x 768 Monitor : Larger than 15 inch, & 17 inch is recommendedMonitor : Larger than 15 inch, & 17 inch is recommended Serial port & USB port availableSerial port & USB port available

4 User Login Install the driver of encrypt USB keyInstall the driver of encrypt USB key Driver file: SP1730RC9.zipDriver file: SP1730RC9.zip Default user name: adminDefault user name: admin Password: mcquaymds (can be amend)Password: mcquaymds (can be amend)

5 Menu Introduction File Menu “Exit” only“Exit” only Function Menu Initiating: Hardware changesInitiating: Hardware changes Error History: to record the faults in the systemError History: to record the faults in the system User Manager: to manage the user name & passwordUser Manager: to manage the user name & password Parameter Setting: to set parameter of the systemParameter Setting: to set parameter of the system Prompts for the units running Prompts for the units running

6 ID Monitor From the 1 st tab on the left, user can perform related operation to the ID connected to OD 1. Select OD follow by ID 2. Select ID operation 3. Adjust ID temperature 4. Turn ON / OFF 5. Click “Confirm” to achieve operation 6. Double click to see Real Time Fault

7 Grouping & Timer 1. Click 2. Select Default group number 3. Select ID number 4. Click to select the customized group number (Max member in a customized is 48) 5. Add the selected ID to the customized group 6. Edit the customized group name & ID name 7. Click “Edit” button to enter Timer setting 8. Timer Mode Setting

8 System Monitor From the 2 nd tab on the left, user can control the ID & OD 1. Double click the ID icon. A window will pop up 2. Right click the ID icon, user can lock the ID 3. Indication of model icon

9 Circuit & Server Monitor Please connect ENCRPT USB KEY of PC, then connect to Smart Commander software for debugging. Using service ENCRPT USB KEY will not display Circuit Monitor & Server Monitor. Please use customer software after debugging. Customer software will only display ID control & system monitor interface.

10 Circuit Monitor Used to monitor ALL parameter of ID & OD Observe ALL parameter of OD through collect address codeObserve ALL parameter of OD through collect address code

11 Circuit Monitor OD parameterOD parameter Single, Master, Slave Cooling, Heating, Defrost, Stop Display OD program OD output capacity (Include Slave) T sh_out : OD superheat Digital compressor output % OD Fan: Stop, Low, High HS: High Pressure (bar) LS: Low Pressure (bar) Heating electronic expansion valve Subcool electronic expansion valve Bypass way vale High pressure / Low pressure switch

12 Circuit Monitor OD parameterOD parameter TH1: Discharge air temp TH2: The 1 st condenser entering temp TH3: The 1 st condenser middle temp TH4: The 2 nd condenser entering temp TH5: The 2 nd condenser middle temp TH6: Entering water temp TH7: Heating water temp TH8: Outdoor temp TH9: Temp before subcool TH10: Temp after subcool TH11: Subcool loop exit temp TH12: Suction temp Sensor is unavailable

13 OD System Theory Diagram OD address number Red Line: Heating Green Line: Cooling / Dehumidify Black Line: Stop Sensor position is hint position

14 ID System Diagram Parameters Click “Up” or “Down”, ID address number will move up or down Click “Back Page” or “Next Page”, the page will turn up or down Address number of ID

15 ID System Diagram Parameters Click “Ctrl” to set ID Choose optional parameters to control single unit Choose optional parameters to control single unit Optional mode: Stop, Cooling, Heating, Dry, Fan Optional mode: Stop, Cooling, Heating, Dry, Fan Fan Speed: Low, Medium, High & Auto Fan Speed: Low, Medium, High & Auto Assistant function: Aux heater, Swing & Lock Assistant function: Aux heater, Swing & Lock

16 Circuit Monitor 1.Modify OD parameters setting Defrost curve A, B point. Default setting A is -6 °C, B is -24 °CDefrost curve A, B point. Default setting A is -6 °C, B is -24 °C Defrost Finish Temp: defrost stop when TH9 achieve this tempDefrost Finish Temp: defrost stop when TH9 achieve this temp Defrost Interval Time: defrost stop when compressor runs for this interval timeDefrost Interval Time: defrost stop when compressor runs for this interval time TscA1, TscA2, TscT1, TscT2, TscT3TscA1, TscA2, TscT1, TscT2, TscT3 When TH9 ≤ TscA1, subcool is TscT1 When TscA1 < TH9 ≤ TscA2, subcool is TscT2 When TH9 > TscA2, subcool is TscT3

17 Server Monitor Used to obtain graph for parametersUsed to obtain graph for parameters Observe operationObserve operation Input or Output data from parameters fileInput or Output data from parameters file Max. 5 parameters will be displayedMax. 5 parameters will be displayed 5 colours on top left indicate the parameters5 colours on top left indicate the parameters

18 Server Monitor Coordinate code name Idiographic machine address code 1 digit – OD 2 digit – ID Detail parameter name Y- axis scale

19 Server Monitor Function Button: Page of display section No. of pages Go back to 1 st page Go back to previous page Go to next page Go to the last page Go to parameter setting Output data

20 Wiring Connection

21 Thank You

22 Error History Record

23 User Manager To add user: Key in user name Key in password 1. Click “Add” To modify: Key in user name Key in new password 1. Click “modify” To delete user: Select the user in the list 1. Click “Delete”

24 Parameters Setting System shut down 3 minutes when switching from “cool” to “heat” or vice versa Min. running time before switching to another mode Lock screen interval time - Unit in seconds - Unlock password: mcquaymds Click this will shown as follow

25 Parameters Setting

26 Stage History

27 ID Monitor

28 1. Choose number of the OD 2. Choose number of the ID

29 ID Monitor Multiple Control : Single Control : Select a indoor unit only Select many indoor units Group Control : All the indoor units in the system

30 ID Monitor Select fan speed: (must select) Select mode (must select) Select assistant functions:

31 ID Monitor Click “ ” or “ ”, can adjust the set temperature Select “ ” or “ ”, can turn on or close the units Click “ ”, can send the order to the units

32 ID Monitor The error list window pops up:

33 Group Set & Timer

34 Select OD Click on the cell to select ID

35 Customized Group Setting

36 After select the ID, click this button To delete the selected ID, click this button

37 Customized Group Setting To edit customized group name: 1. Key in group name 2. Click “Refresh” To edit ID name: 1. Key in ID name 2. Click “Refresh”

38 Timer Setting To add/delete the timer mode: 1. Key in name 2. Click “Add” or “Delete” Select Timer Mode To Add, Delete or Modify a task

39 Timer Setting First mode: Select ON/OFF task

40 Timer Setting Second mode: Select only “ON” or only “OFF”

41 Timer Mode Setting 1. Select ID 3. Click “Set” 2. Select Mode

42 System Monitor

43

44 Left click to select the locked function

45 System Monitor

46 Circuit Monitor

47 Defined defrost area Defrost stop 2 nd defrost start after 1 st defrost TH9 ≤ TscA1, subcool is TscT1 TscA1 < TH9 ≤ TscA2, subcool is TscT2 TH9 > TscA2, subcool is TscT3

48 Server Monitor Value of the parameters Move the pointer to the desired point

49 Server Monitor Y1~Y5: parameter setting: Tick to select ID parameter to be displayed Max. value of Y-axis Min. value of Y-axis Major unit Display the data of selected date Display the data of real time Click to display the graph Input file

50 Server Monitor Output Data:


Download ppt "TECHNICAL TRAINING 2007. SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB."

Similar presentations


Ads by Google