Fan Coil Unit Product Line-up. FCU Home Application Show.

Slides:



Advertisements
Similar presentations
Packaged Terminal Air Conditioners
Advertisements

Series L Air conditioners for Laboratories.
Trane Voyager™ rooftop units
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International dept. STAR 24 3 E.
SINGLE SPLIT INVERTER AIR-CONDITIONER
HEAT PUMPS.
STAND ALONE CONTROL FOR TERMINALS
Trane Variable Water Flow System
AIR CONDITIONING ACCESSORIES
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
Engineer Presentation
Management training Jumeirah beach residence sector 3 Presented by November 15 th 2006.
YFCC ‘COANDA’ CASSETTE UNITS
Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
Product Introduction.
Aqualean Product Presentation 1 By Laurent Domenget Product Manager, Rooftop & Packaged Air Units.
RLC-CMS002-E4© American Standard Companies, inc All Rights Reserved Concentration of intelligence, High reliability. Series R TM.
Daikin Australia Pty. Limited Ducted Split Systems 2011.
Air conditioning – Refreshes your life Applied Systems DAIKIN Fan Coil Units Comfort Applications >> FWB
‘YGFC’ FAN COIL UNITS NEW PRODUCTS
Hydronic Global Satellite Program highlights
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
2010.
Alan Hinton March, 2006 Slide 1 NEW! ‘YEFB’ HIGH PRESSURE BLOWER UNITS.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Hydraulic Kit (pump and tank) Pictures from prototype.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
Heat Exchange Ventilation Heat Exchange Ventilation.
Product Presentation 2007 SKY AIR Launch of new Non-Inverter + Duct (R22) series.
Aztec Sensible Cooling System  Series ASC 1A01  Indirect Cooler –No direct contact of water into the supply air –Stainless steel cooling tower –Fill.
Product Section Product Training. 50 Hz R410A R22 R407C Ceiling Convertible CE-E Series.
MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.
System Components Let’s take a look at the Spacepak System Components.
New MSP Concealed Ceiling Unit (FBQ-D & FXSQ-A)
Introduction of New Wall Mounted AVS 18-24URCSBBA Commercial Air Conditioning Dept
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
DC Inverter Mini VRF Reference projects Reference Project Mini and Multi Improvements Product line -up.
Refrigerant system of Inverter R-410A. denki.co.th Model type Model : Stand Model : Duct Model : Cassette Model : Wall mount Model : Wall and.
2016 Chiller New Products Presentation.
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
CHIGO HVAC Product Introduction.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Fan Coil Controller FC/S 1.1
The New Digital Inverter Light Commercial Range
Compact line ‘EW*D~J-’ water-cooled chiller range
Section 6: Air-Conditioning (Heating And Humidification)
Specializing in Water-Cooled & Portable-Split Air Conditioner
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
BUILDING HEATING AND COOLING
Ritchie Yellow Jacket Instrument Applications
COMFAIR HD WALL WATER FAN COIL UNIT
Ceiling Convertible (MCM-E Series)
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
‘YGFC’ FAN COIL UNITS NEW PRODUCTS
‘SAPHIR’ FAN COIL UNITS…..
VED and VEDI VED and VEDI.
OEM range.
FCL FCL.
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
Air Conditioning System-1
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Ceiling Convertible (ACM-E Series)
Ceiling Convertible (ACC75~100D Series)
Dunham Bush Air Cooled Package
Ceiling Convertible (MCC075~100D Series)
Presentation transcript:

Fan Coil Unit Product Line-up

FCU Home Application Show

How to Read the Model No.? I F -- Function control R Remote control RA Remote control with heater E with electric heater Nominal Air Volume (CFM) H High Static Pressure __ Normal Static Pressure Type Codes C4 Cassette 4 WayC1 Cassette 1 Way CC Cassette Compact H1 Duct TypeH2 2 nd Generation Duct Type H3 Duct Type High Static F1 Floor Open Side IntakeF2 Floor Open Bottom Intake F3 Floor Concealed MW Mid-Wall Type Chilled Water fan Coil Unit

All Series (Present Product) 4 way Cassette Compact 4 way cassette Series Model IFC4-xxHRN4 Model Air Volume (CFM) Series Air Volume (CFM) 600~1500 IFCC-xxHRN4300~500 One 1 Cassette IFC1-xxxHRN4 300~600 Floor Standing IFC1-xxHRN4 IFC2-xxHRN4 150~1000 Floor Standing IFC3-xxHRN4 150~1000 Duct 2-rows IFH2-XHRN4 IFH2H-xHRN4 200~1400 Duct 4-rows IFH1-xxHRN4 IFH1-xHNR4 300~2000

All Series (New Products) New 4 way Cassette New Compact 4 way cassette Series Model IFC4-xxxR/RA With Auxiliary Electrical Heater Model Air Volume (CFM) Series Air Volume (CFM) 600~1500 IFCC-xxxR/RA With AEH 300~500 New 1 way Cassette IFC1-xxxR/RA With AEH 300~400 Wall mounted Duct 2-rows IFH2-xxxE IFH2H-xxxE With AEH & Plenums 200~1400 High Static Pressure IFH3H IFH3H-xxxE With AEH 800~2200 Duct 4-rows IFH1-xxxE With AEH & Plenum 250~ ~ ~1200 Mass production on June 1 st, 2008 Duct New 3-rows IFMW

Duct Type 2-Rows IFH2 Series Air volume: CFM Air return plenums and air filter are optional IFH2 static pressure is 12Pa IFH2H static pressure is 30Pa, and 50Pa can be customized. be customized. 2-Rows IFH2-XXXE Series (With Auxiliary Electrical Heater) Air volume: CFM Air return plenums and air filter are standard IFH2-xxxE static pressure is 12Pa IFH2H-xxxE static pressure is 30Pa, and 50Pa can be customized.

Duct Type New 3-Rows Air volume: CFM Air return plenums and air filter are optional The working static pressure of standard series is 12 Pa, and which of high static series is 30Pa. Also 50Pa can be customized.

Duct Type 4-Rows IFH1 Series Air volume: CFM Air return plenums and air filter are optional static pressure is 12Pa 4-Rows IFH1-XXXE Series (With Auxiliary Electrical Heater) Air volume: CFM Air return plenums and air filter are standard static pressure is 12Pa

Duct Type  Elegance and prestige----Concealed installation makes the conditioned space more concordant.  Low thickness for easy installation and maintenance.  Low noise fan direct driven by 1 phase and 4 speed setting motor, so there are more choices for variable applications.  The plenum and the air filter are standard, so it is very easy to install.  The auxiliary electrical heater and the new electronics thermostat are standard. And the heater can be controlled independently. Features

Duct Type L (mm) Connection from right side Note: 1.Only 1400CFM type is 3 rows; 2.Pipe connection way can be selected from left or right. 3.IFH2 Pressure is 12 Pa 4.IFH2H pressure is 30 pa, and 50Pa can be customized. LCFMdB (A)

ModelCFM Cooling Capacity Heating Capacity Power Input Static Pressure Electrical Heater IFH2(H)-200(E) W3210 W43 W12(30) Pa500W IFH2(H)-300(E) W4310 W59 W12(30) Pa650W IFH2(H)-400(E) W5410 W72 W12(30) Pa1000W IFH2(H)-500(E) W6800 W84 W12(30) Pa1000W IFH2(H)-600(E) W8100 W105 W12(30) Pa1500W IFH2(H)-800(E) W11000 W150 W12(30) Pa2000W IFH2(H)-1000(E) W13500 W172 W12(30) Pa2000W IFH2(H)-1200(E) W16500 W210 W12(30) Pa3000W IFH2(H)-1400(E) W19500 W250 W12(30) Pa3000W Specifications Duct Type

L 490 (590) 240 (340) (mm) Note: 1.Pipe connection way can be selected from left or right. 2.Pressure is 12 Pa 3.Available for 50Hz & 60 Hz LCFMdB (A) ×340× ×340×

ModelCFM Cooling Capacity Heating Capacity Power Input Static Pressure Electrical Heater IFH W3510 W43 W12 Pa600W IFH W4680 W44 W12 Pa1500W IFH W5260 W55 W12 Pa1500W IFH W5850 W60 W12 Pa1500W IFH W7020 W105 W12 Pa1500W IFH W8840 W119 W12 Pa2000W IFH W9880 W124 W12 Pa2000W IFH W10900 W162 W12 Pa2000W IFH W14000 W175 W12 Pa2400W IFH W17550 W236 W12 Pa2400W IFH W23400 W360 W12 Pa3000W Specifications Duct Type

Optional Accessories  Air return plenums, electrical heaters, 3-way valves, thermostat. For the units without Electrical Heater

Duct Type Optional Accessories  New electronic thermostat especially for the units with electrical heater. For the units with Electrical Heater

Duct Type Typical Installation 1 Installation

Duct Type Typical Installation 2 Installation

Duct Type Installation Typical installation sketch (With 2-way valve)

Duct Type Installation Typical installation sketch (With 3-way valve)

High Static Pressure Duct Type 800, 1000, 1200, , 2000, 2200 IFH3H Series Air volume: CFM Air return plenums and air filter are included For 800 to 1400 CFM unit, the working static pressure is 70Pa For 1600 to 2200 CFM units, the working static pressure is 100Pa

High Static Pressure Duct Type IFH3H-xxxE Series Air volume: CFM Air return plenums and air filter included as well as Auxiliary Electrical Heater For 800 to 1400 CFM unit, the working static pressure is 70Pa For 1600 to 2200 CFM units, the working static pressure is 100Pa 800, 1000, 1200, , 2000, 2200

High Static Pressure Duct Type Features High air volume, high static pressure, high capacity Easy to clean or change the air filter Extra drain pan to protecting your ceiling Includes air plenum, air filters.

High Static Pressure Duct Type ModelCFM Cooling Capacity Heating Capacity Power Input Static Pressure Electrical Heater IFH3H W5860 W350 W70 Pa3000W IFH3H W7910 W350 W70 Pa3000W IFH3H W9670 W350 W100 Pa3000W IFH3H W 350 W100 Pa3000W IFH3H W13480 W650 W100 Pa10 kW IFH3H W15530 W1020 W100 Pa10 kW IFH3H W19340 W1140 W100 Pa10 kW Specifications

New Cassette Type Body Dimensions (mm) : 850×235×400 Panel Dimensions (mm) : 1050×18×470 CFM Cooling Capacity dB (A) Electrical Heater W W W W IFCC-xxxR/RA Series R means normal models RA means the models with auxiliary electrical heater

New Cassette Type Dimension (mm): 580×254×580 Panel Dimension (mm): 650×30×650 Dimension (mm): 840×240× ×310×840 Panel Dimension (mm): 950×40×950 Compact type IFCC-xxxR/RA Common type IFC4-xxxR/RA CFM Cooling Capacity dB (A) Electrical Heater W W W W W 40.8/ W42.5/ CFM Cooling Capacity dB (A) Electrical Heater W W W W W W W W W W W W

New Cassette Type  Built-in body design, integrative design with the ceiling, makes the installation room more concordant;  Built-in high head drain pump can lift the condensate water up to 500 mm and drain out smoothly;  New designed coils makes the water pressure drop decrease and makes the capacity higher;  4-speed motor gives you more choices.  Brand new appearance of common 4-way cassette. Features

Floor-standing Type Dimension (mm): 550×212× ×212× ×212× ×212×545 Concealed type IFF3 Dimension (mm): 880×225× ×225× ×225× ×225×626 Exposed type IFF1 air return from side IFF2 air return from bottom CFM Cooling Capacity Heating Capacity dB (A) W2540 W W4170 W W5640 W W7220 W W8850 W W10280 W W12240 W W15350 W W18200 W 48

Floor-standing Type Available now! New grill Exposed type IFF4 IFF5 Special design

Floor-standing Type Features  All metal parts are made of commercial grade galvanized steel, providing maximum protection against corrosion.  Soft, streamlined appearance.  Air filter is easily removed and cleaned.  Low noise fan direct driven by single phase and 3 speed setting motor  If cooperate with the newly designed thermostat- KJR-15B/E(P), when the inlet water temperature is higher than 20 ℃ in cooling mode or lower than 35 ℃ in heating mode, the fan will be shut down automatically to maintain the comfort.

Floor-standing Type Features  Thermostat and 3-way valve are optional

Wall-mounted Type  Air volume range: 250, 300, 400, 500 and 600 CFM.  The appearance is the same as wall mounted indoor unit for MDV NEW IFMW Series!

Thank You!