Presentation is loading. Please wait.

Presentation is loading. Please wait.

Trane Variable Water Flow System

Similar presentations


Presentation on theme: "Trane Variable Water Flow System"— Presentation transcript:

1 Trane Variable Water Flow System
Outdoor Air-cooled Water Chiller Installation, Operation & Maintenance

2 Trane Variable Water Flow System
Introduction What is VRF system? System Profile System & Components Chiller Unit Nameplate

3 Trane Variable Water Flow System
4/11/2017 Trane Variable Water Flow System What Is It? A newly designed, digitally controlled air-cooled variable water chiller system Variable Refrigerant Flow in Refrigeration Loop & Variable Water Flow in water loop Water used as heat transfer media, no refrigerant in occupied space Digital Chiller Central Controller RS485 Trane Variable Water Flow System Remote Controller High Wall Cassette Concealed Inflow Water loop Communication line Thermostat Outflow Water loop 3

4 Cooling capacity range
Outdoor Unit Digital Scroll Compressor Built-in two-speed water pump Fan design delivers reduced noise levels Cooling capacity range 6RT 8RT 10RT 12RT 14RT CGD*100/ 120/ 150/ 175/ 200 Cooling: 24.5kW kW Heating: 24.5kW kW Power source: 220V/60Hz/3Ph 380V/50Hz/3Ph

5 Outdoor Unit 10RT 12RT \ 14RT 6RT \ 8RT
Digital Fixed Digital Fixed Digital Fixed Fixed Cabinet Size (mm) (HxWxD): ,900 x 1,290 x 600 Cabinet Size (mm) (HxWxD): ,900 x 1,990 x 600 Cabinet Size (mm) (HxWxD): ,900 x 1,990 x 600

6 Digital Scroll Compressor
Pulse Width Modulation (PWM signal) 10-100% continuous capacity control Superior performance Simplified control parts The PWM valve is designed specially as a solenoid valve to modulate the pressure forcing on the fixed scroll and controlling the compressor’s loading/unloading. The PWM receives the On/Off signal and controls the loading/unloading status. When the PWM valve is turned off, the fixed scroll is pushed down to the orbiting scroll (Loading). When the PWM valve is turned on, the fixed scroll is separated from the orbitingscroll(Unloading). This process is repeatedly done to make the outdoor unit control automatically depending on the number of operating indoor unit(s) and their heating/cooling demand. To summarize the performance of the Digital Scroll compressor: One : There will be running cost savings due to the high efficiency of the compressor. Two: Your customers will have more comfort. The wide capacity range will be able to control the room temperature and humidity very precisely. Three: The system will be reliable – the compressor is extremely reliable and the electronics is simple. There is no need to worry about oil return for any operation Four: There is no electromagnetic interference issue

7 Controllers Central controller is a “must have”
Unit Controllers Type Central Controller (Standard) System Controllers Type of ID Wired Remote Concealed Not Available Cassette Central controller is a “must have” Wired thermostat is Trane Patented design Color back light Last setting for resuming power Hi-Wall Not available

8 Controllers Wired Controller Remote Controller Central Controller
Remote ON/OFF fan coil Function setting, temperature regulation, air velocity setting Sleep mode setting, timer setting function Remote control distance ≥5M Patented design LCD display Cooling/heating/ ventilation control Sleeping mode Last setting for resuming power Multi-zone control Individual zone control Troubleshooting Timer setting Mode setting

9 How to Select “EarthWise”
4/11/2017 How to Select “EarthWise” OD Parameter Setting: Set leaving water temp to 5°C via central controller In-Door Unit Selection: Concealed unit: select “Earthwise” application High wall & Cassette: Not available Digit 17: Application N = Normal application E = Earthwise Choose “Earthwise” option in TDS tools to run product configuration report

10 Model Number Description
C G D K H E A Z R N R R A C ,6, Digit 1,2,3 — Unit Type CGD= Digital Air-Cooled Water Chiller Refrigeration Circuit Digit 4 R = Heat Pump K = Cooling Only Digit 5-7 — Nominal Capacity (Tons) 100 = = = = = 14 Digit 8 — Voltage Selection 2 = 220V/60 Hz/3 ph 5 = 380V/50 Hz/3 ph Digit 9— Airflow Configuration H = Horizontal Digit 10— Refrigerant E = R-22 Digit 11 — Manufacturing Code (defaulted by factory) A = Double Compressors B = Triple Compressors Digit 12 — Central Controller Z = With Central Controller (as standard) Digit 13 — Chilled Water Pump R = Water Pump Digit 14 — Auxiliary Electric Heater in Water Circuit N = None Digit 15 — Ambient Temperature R = Standard Ambient Temperature Set (Standard) Digit 16 — Water Pipe Direction (Face to the Airflow) R = Right Side (Standard) B = Back Side (Optional) Digit 17 — Design Sequence (Not for client) A = First Version B = Second Version Digit 18 — Region V = China A = APR B = MAIR C = LAR

11

12

13

14

15

16

17 PVC pipe and fitting price is 4 times cheaper than steel pipe’s.
PVC Pipe Installation Benefits PVC pipe and fitting price is 4 times cheaper than steel pipe’s. PVC Pipe weight is 6 times less than steel pipe’s. Use smaller pipe size because friction loss of PVC pipe is much less than steel pipe’s. Easy transportation, Easier and quicker installation, longevity

18 PVC Pipe Installation Benefits
Size PVC Class 13.5 (Kg/m) Steel Sch#40 (Kg/m) Size Diff. (time) ½” 0.22 1.26 5.7 ¾” 0.265 1.68 6.3 1” 0.417 2.50 5.9 1 1/4” 0.542 3.39 6.2 1 1/2” 0.7 4.06 5.8 2 1.075 5.48 5.0 2 1/2” 1.712 8.66 3” 2.375 11.3 4.7 3 1/2” 3.852 13.7 3.5 4” 5.0807 16.2 2.7 5” 8.092 22.0 6” 12.515 28.5 2.2

19 PVC Class 13.5 vs Black Steel Pipe #40 (ERW)*
PVC Pipe Installation Benefits Size PVC Class 13.5 vs Black Steel Pipe #40 (ERW)* ½” 64% ¾” 67% 1” 1 1/4” 1 1/2” 63% 2” 59% 2 1/2” 57% 3” 53% 4” 37% 5” 43% 6” 39% 8” 33% *The percentage price difference is based on the price in Thailand.

20 Black Steel Pipe #40 (ERW) PHP/m
PVC Pipe Installation Benefits Size PVC Class 13.5 PHP/m Black Steel Pipe #40 (ERW) PHP/m ½” 16 45 ¾” 19 57 1” 31 87 1 1/4” 40 120 1 1/2” 52 138 2” 78 188 2 1/2” 130 300 3” 180 386 4” 289 462 5” 436 766 6” 615 1,006 8” 1,046 1,555

21 Black Steel Pipe #40 (ERW) THB/m
PVC Pipe Installation Benefits Size PVC Class 13.5 THB/m Black Steel Pipe #40 (ERW) THB/m ½” 12.6 34.65 ¾” 14.7 44.10 1” 24.15 67.20 1 1/4” 30.45 92.40 1 1/2” 39.90 106.5 2” 59.85 144.9 2 1/2” 99.75 231.0 3” 138.6 297.15 4” 222.6 355.95 5” 336 590.1 6” 473.55 774.9 8” 805.35 1,197

22 PVC Pipe Installation

23


Download ppt "Trane Variable Water Flow System"

Similar presentations


Ads by Google