1 Compact line ‘EW*D~J-’ water-cooled chiller range
- Product presentation - Applied Systems - Strategic Marketing Daikin Europe NV

2 CONTENTS 1. What’s changing? Replacement of EW*D~MBYNN Position in our W/C range 2. What are we going to offer? Features & benefits Capacity classes Operation range Energy efficiency Dimensions Connections Options 3. Conclusion

3 Chapter 1 --------------------------------- What’s changing?

4 1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range
Current product portfolio: COOLING CAPACITY (kW) 50 100 250 500 750 1000 1250 1500 2000 R-410A & 407c Hydrocube EWWP KBWN (incl. EWLP) EWWQ~B- R-134a EW*D~MB REPLACEMENT EW*D~J- EW*D~G- EWWD~H- (Flooded technology) EW*D~I- INVERTER EWWD~FZ DWSC/WDC (Centrifugal Chiller) (DWSC up to kW) (DWDC up to kW) 4

5 1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range
Current range overview: MODEL CHANGE! Model change includes: 1 Complete range will feature: - extended capacity range - new compressor - new controller 2 Complete range will be updated with regard to: - option configuration - warranty 1year standard instead of 3 extendable up to a maximum of 4 years warranty applicable on parts only

6 1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range
Product Water-cooled chiller with single screw compressor Refrigerant R-134A Series name EW*D~J- ¹ Cooling capacity From 120 kW up to 570 kW (nominal conditions) Circuits 1/2 circuits (1/2 compressors) Efficiency versions S Standard efficiency Sound versions S Standard sound New range overview: Note ¹ Also available as condenserless series ‘EWLD~J-’

7 1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range
New range overview: Product line-up: ‘EW*D~MB’ replaced by ‘EW*D~J-‘ range Current situation New situation

8 1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range
Product positioning: WATER COOLED EW*D~G- EWWD~H- NEW Direct expansion EWWD~FZ Flooded EW*D~I- EW*D~J- DWSC/DWDC EWWQ~B-

9 Chapter 2 --------------------------------- What are we going to offer?

10 2.1 Features & benefits wide capacity range: 120 – 570kW
2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options wide capacity range: 120 – 570kW compact design to allow easy indoor installations or retrofit operations availability of both standard and condenserless units high energy efficiency (EER up to 4.41, ESEER up to 5.37) upgrade of chiller controller to Microtech III easy integration with control systems (BMS, sequencing panels) extensive option list, including heat pump version

11 extended capacity range
2.2 Capacity classes 2.1 Features 2.2 Capacity 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: ● Standard efficiency – standard sound Current situation New situation extended capacity range additional sizes

12 extended capacity range
2.2 Capacity classes 2.1 Features 2.2 Capacity 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Condenserless unit: ● Standard efficiency – standard sound Current situation New situation extended capacity range additional sizes

13 Standard efficiency – standard sound
2.3 Operation range 2.1 Features 2.2 Capacity 2.3 Operation 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: Standard efficiency – standard sound Operation with Glycol ICE mode Operation with Glycol (below 4°C ELWT) = Units should not be able to reach the minimum capacity when working in part load

14 Standard efficiency – standard sound
2.3 Operation range 2.1 Features 2.2 Capacity 2.3 Operation 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Condenserless unit: Standard efficiency – standard sound Operation with Glycol ICE mode Operation with Glycol (below 4°C ELWT) = Units should not be able to reach the minimum capacity when working in part load

15 2.4 Energy efficiency levels
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: New range Current range EER comparison Up to 8% increase in EER

16 2.4 Energy efficiency levels
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: New range Current range ESEER comparison

17 COMPACT LINE! 2.5 Unit dimensions Current situation New situation
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Dimensions Dimensions of the new units will be the same as the current EW*D~MB range COMPACT LINE! Current situation New situation

18 2.6 Connections Connections: Hydraulic side (dual compressor unit)
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Connections: Hydraulic side (dual compressor unit) Note 1 – Units are mechanically linked Note 2 - Connection pipes are NOT provided by Daikin Evaporator water IN Condenser water OUT Condenser water IN Evaporator water OUT - Evaporator water inlet/outlet: 76,2mm - Condenser water inlet/outlet: 4’’ (2½’’ on size 120)

19 2.6 Connections Connections: Electric side (dual compressor unit)
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Connections: Electric side (dual compressor unit) One Microtech III controller on the superior unit (master) is connected through RS485 with control modules on the lower unit (slave) Communication through cables between the two units Main switch Cables IN (side entry)

20 Microtech III controller (Siemens)
2.6 Connections 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Connections: Electric panel Current situation New situation Microtech III controller (Siemens) Microtech II controller (Carel) Emergency stop (standard) Emergency stop (standard) Main switch (standard) Note: Main switch available as option

21 2.7 Options & accessories A) Options Compared to MB-series:
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options A) Options 1) Standard factory mounted The base model will include here below standard factory mounted options: Compared to MB-series: electronic expansion device: STD suction shut off valve: STD main switch: STD compressor fuse protection: STD

22 Extensive list of options
2.7 Options & accessories 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options 2.7 Options 2.7 Options A) Options 2) Options on request Below mentioned options will be available for the new ‘EW*D~J-‘ range: Current situation New situation Extensive list of options

23 2.7 Options & accessories B) Accessories
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options B) Accessories The R-134a ‘EW*D~J-‘ range will feature the new Microtech III controller Main features: ▫ Unit controller fully programmed and engineered by Daikin on Siemens hardware ▫ P.I.D. logic (proportional, integrative, derivative) ▫ Easy visual interface with 4 rows display and 3 keypads ▫ Push and roll navigating wheel ▫ Modular control solution: ▫ Freely programmable controllers ▫ Extendable with additional I/O modules ▫ Extended temperature range (-40ºC up to +70ºC) ▫ Field installable COMM modules (integration) ▫ Advanced (remote) servicing possibilities Microtech III

24 2.7 Options & accessories Current situation New situation
2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options 2.7 Options B) Accessories Below accessories will be available: Current situation New situation

25 Chapter 3 --------------------------------- Conclusion

26 Superior control logic
Small package, great chiller The new compact line ‘EW*D~J-’ chiller range features compact design, maximum efficiency and superior control logic, offering flexible solutions for a wide range of comfort and process applications Application flexibility Easy indoor installation & retrofit operation The EW*D-J- series is available in a wide range of capacities ( kW), allowing project solutions for an extensive range of applications. Water cooled units are typically intended for indoor installation and operation, resulting in acoustic isolation and also zero impact on the building layout. Thanks to the compact design, the EW*D-J- series allow easy indoor installations and retrofit operations. Superior control logic New MicroTech III controller provides easy to use control environmental and an easy interface with LonWorks, BACnet, Ethernet TCP/IP or Modbus communications