PALOMINO VALLEY GID WATER SOURCES Truckee Meadows Fire Protection District.

Slides:



Advertisements
Similar presentations
General Safety Overview and Information
Advertisements

Dennis Fire Appliances Operations & use. PTO Step 1 Move slide cover towards the drivers seat to lock out the gearbox Step 2 Select drive on the gear.
Circulating Water System
Automobile Engine NO.4. NO.1 Mercedes-Benz E-class.
ADX 150 – Engine Repair ADX 170 – Climate Controls
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
TFT Blitzfire.
ENVIRONMENTALIST II-B WATER RECLAMATION SYSTEM. GENERAL INFORMATION EV II-B A compact water recycling system designed to reduce water consumption and.
Safety Gas Plus.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
LESSON TWO BEFORE YOU GET UNDERWAY. Key Topics Vessel’s capacity Vessel’s capacity Float plans Float plans Fueling a vessel Fueling a vessel Trailering.
CAFS On-Line Orientation
Introduction to Truck 3 Pierce 105’ Aerial
Tandem Pumping Video. INITIAL SIZE-UP When approaching the structure note the location of the FDC, Hydrant and Building Access.
Discharging CAF Streams In reality anything that will let the stuff out of the end of the hose will work. The early mantra was that a shut off gate and.
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Driver Recert 2012 Topics Update on Fire Hose Friction Loss Coefficients Fire Flow Through Long LDH Supply Lines Rural Water Supply Flow Rates Booster.
The DB In-Line Pumpout Unit Easy-to-use control panel with one switch to run the unit. 15 AMP reset fuse. 115 AC External water pump and tank drain have.
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
Sunday, May 17, 2015 Pressure Booster Service. Sunday, May 17, 2015 Booster Service Basics Control Panel Components Setting a pressure switch Setting.
CVFD Training – Water Supply SFFMA Training Objectives: –
Dennis Sabre Fire Appliances
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Chapter 9 Water Supply.
Station 31 & Station 35 Procedures for fill station with booster pump.
Intermediate SFFMA Objectives: – Hrs received.
Hydronic Mechanical Controls
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
DISPENSING FUEL HSE CONSIDERATIONS 1. FUEL TANKERS Road tankers or bowsers which refuel vehicles, plant, and equipment shall be subject to scheduled inspection.
Water Handling Operations
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
Propellers The engines are equipped with four bladed, full
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Air Valve Switch System Upgrade for MACI 2500L Fire Truck Current system Operation (Structural) The current valves operate when is applied to one side.
Water Supply Skill Drills.
Lift Station Safety and Maintenance Tony Conn, Supervisor Wastewater Collection and Pumping
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Unit - #6 Air Brake System
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
Tank plumbing 250 Telone 1/2013. Dip tube connection on Left Nitrogen Connection on Right.
21 Fire Suppression Skill Drills. 2 Objectives Apply water using the direct, indirect or combination attack. Use a large handline using the one- or two-
Las Delicias Water Supply System OPERATION AND MAINTENANCE MANUAL 1.
State of Oregon, DAS Fleet Fuel Island Operations - E-85.
Firefighter III Module B Water Supply (4-19) (4-19)
Presented by: Rick Kuemin, MSA Training Director
Diesel Fuel - Fill Place all spill safety equipment where needed
PROSSER PUMP Long Beach Fire Department. BASIC SET- UP Components Main dewatering pump Junction box Attached power cord Additional extention cord.
Attack lines and pumping. What lines to pull?  Engineers should be able to understand what hose lines are for what purpose, what GPM they operate at,
Tanker Operations In Water Supply Michael Crawford July 2002.
MODULE 2 Operate the Propane Liquid Supply System.
Connections are loose for draining pump Water in From street Water out to house This is the setup for public water Pressure and the pump system turned.
Southeast Financial Center
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
Procedures.
Water Shuttle Operations
2010 Union County Water Movement Training Review Leesburg Twp. September 18, 2010.
ATP FOAM SYSTEM Engine 438 Ansul / Rockwood Model B2 400 GPM Around The Pump Foam System.
Pumped Discharge. Brian Makin 14/
2013Q1.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Diesel Automotive Engines
SB Packing Automatic Downpuller Power Unit
Instructions: Adding refrigerant fluid to system
Filling of SAPPHIRE 25 & 42 Bar Systems (TFPP Hardware)
The Heart and Blood Pressure
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Compressor Operating Instructions
Presentation transcript:

PALOMINO VALLEY GID WATER SOURCES Truckee Meadows Fire Protection District

Suppression Water Sources 2 Locations authorized for TMFPD use:  SR445 (Pyramid Hwy) and Ironwood Road  Located across the Horse Corral.  5105 Wayside Drive (PVGID yard)  Take Whiskey Springs road about two miles from SR445 to Grass Valley road (just past the BLM Station). Turn left on Grass Valley road and Wayside drive is about ¼ mile on the right.

Suppression Water Sources SR445 and Ironwood Road

Suppression Water Sources 5105 Wayside Drive

SR445 and Ironwood Road Water Source Gates are equipped with TMFPD combination locks intermingled with PVGID pad locks Operation Overview: Caution: make sure that you have the correct valves on the fill pipes at this location open and/or closed or you could get VERY wet. If you are filling a Water Tender that has a top fill hatch and have a spotter to help getting under the overhead fill, you may consider using the overhead fill pipe. This location makes about 390 GPM. There are two gate valves on the fill tower. The upper valve controls the overhead fill and the lower controls the 2.5” hose connection. To fill by hose you must make sure the upper valve is off and lower valve to hose connection is at least partially open before starting the well. Mounted on the block wall by the fill pipe is a controller switch that starts the generator which in turn powers the well. Approximately 1 minute after the generator starts the well will turn on. Once filled, turn the electric switch back to off. The well will shut down but the generator will run for a cool down cycle then will automatically shut down.

SR445 and Ironwood Road Water Source This site has two gates; one for entry and one for exiting. Enter Ironwood road fill site from the East gate so your control panel is close to the fill valves.

SR445 and Ironwood Road Water Source Connect fill hose to the LOWER valve and to your apparatus. Open intake valve on apparatus. Make sure upper valve is off and lower valve is partially open.

SR445 and Ironwood Road Water Source Turn control switch to “on” and push the “reset” button. This turns the generator on and the well pump will come on within about 1 minute.

SR445 and Ironwood Road Water Source Regulate the fill valve as required for filling. This well produces 390 GPM. It is OK to create some back pressure on the well to regulate your water flow but try to avoid deadheading the water flow completely. Once your apparatus is filled turn the control switch to the “off” position. The well will shut off and generator will shut down automatically after a cool down period. Disconnect hoses.

SR445 and Ironwood Road Water Source Other Well equipment at the Ironwood site. Do not do anything with any of this other equipment at the site.

5105 Wayside Drive Water Source This water supply to the tank is controlled automatically and all you need to do is hook up to the 2.5” connection and open/close the ball valve

Helo Dip Sites Helo dip sites could also be established at both fill locations, but the Wayside Dr. location should be considered first because it is away from public roads and the water system is controlled automatically. Hose lines could be stretched from the water fill connections at each site to a remote dip site if there are personnel to stay at the sites to keep the tanks filled.

Questions Please direct any questions to Wayne Cirone. Thank you