Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.

Slides:



Advertisements
Similar presentations
Pneumatic Principles.
Advertisements

Common Mistakes by Carrie Schroeder. Emission Factors Where did they come from? How old are they? If you changed it in your spreadsheet, make sure to.
TURKEY AWOS TRAINING 1.0 / ALANYA 2005 MEASUREMENT OF VISIBILITY.
1 According to PETROSAFE safety policy, the company is keen that: Introduction All Egyptian Petroleum companies and foreign companies working in A.R.E.
Flammable and Combustible Liquids
The Care and Feeding of Silane Art Garcia FM Global March 23, 2006.
ELLIOTT BAY INDUSTRIES
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Gas Detection Strategies Overview of Selection Criteria for Gas Detection Systems.
SOLARIS 3-GAS METER Complete operation of Solaris multi-gas meter can be found on the LAFD Ethernet.
Compressed Gas Cylinder Safety
General Characteristics of Gas Detectors
Sensor Operating Theory
Module 9 Confined Space.
. Fire Prevention 12 . What will burn? NO FIRE 15% 13.
André Augustinus 15 March 2003 DCS Workshop Safety Interlocks.
Hazmat Industry Technician. Types of Equipment Monitoring equipment Detection devices Air sampling systems.
TYPES OF MECHANICAL SYSTEMS
How Static Electricity Affects Our Daily Lives.  An example of a very large electrical discharge (when electric charges are transferred very quickly)
3.7.6 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
1 Monitor of Isobutane Content in the RPC Gas Mixture Changguo Lu, Kirk McDonald Princeton University (10/22/2008)
PROPERTIES OF FLAMMABLE MATERIALS. Flammability Flammable Flammable –Capable of being ignited and of burning –Synonymous with combustible.
Basic Air Monitoring Concepts And Use Of The Altair 4 Gas Meter
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
Incident Date:1/11/2012 Time:07:30 AM Fatality: 25 injuries: 131 Total losses:
Atlantic Beach Fire Department Presents: For Business Employees and the General Public.
Fires and Explosions.
Condensation Piping and Installation Drain Pans
R Pharmaceuticals Waste Incineration & Heat Recovery at Roche Ireland Ltd. Andrew Carden.
Fire safety is an important business. You need to take proper precaution in order to prevent a fire. Yes, fire may be inevitable but if prepared, you can.
Safe Handling of Flammable and Combustible Liquids
1 Fire Safety Emergency Preparedness Session 10 Laboratory Safety Training.
What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected until a security guard noticed.
3-1 NFIRS 3 Structure Fire Module. 3-2 ObjectivesObjectives The participants will be able to: –describe when the Structure Fire Module is to be used.
Toxic Release and Dispersion Models
Enclosure Fire Dynamics
Evaluation of Safety Distances Related to Unconfined Hydrogen Explosions Sergey Dorofeev FM Global 1 st ICHS, Pisa, Italy, September 8-10, 2005.
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
1/05 Fire Prevention Plan. 2 Notice  This presentation is provided to all Educational Service District 101 (ESD 101) schools at no cost.  This presentation.
Patrick Thornton, SNS/FPE June 9, 2008
Fire Prevention for Construction. Four classes of fires  A, B, C, and D 1a.
FIRES AND EXPLOSION LECTURE 10.
Explosion An explosion is a rapid expansion of gases resulting in a rapid moving pressure or shock wave. The expansion can be mechanical or it can be.
Tyson Burt Mathieu Gagnon
International Conference on Hydrogen Safety 2011 – San Francisco, 12 Sept 2011 Risk informed separation distances for hydrogen refuelling stations Frederic.
Chapter 10: Physical Characteristics of Gases Coach Kelsoe Chemistry Pages 328–352.
FDS5 Simulation Results for VESDA Performance in HKCEC 2MW Fire Test (For internal info only) AEG, Xtralis Jan
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Molecular Kinetic Theory
Chapter 2.1 Introduction to Culinary Arts
Example 2 Chlorine is used in a particular chemical process. A source model study indicates that for a particular accident scenario 1.0 kg of chlorine.
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
Flight Investigations TEXT BOOK CHAPTER 16 PAGE
CHAPTER 17: ELECTRICITY ELECTRIC CHARGE AND FORCE CHAPTER 17: ELECTRICITY.
Grounding & Bonding Hazardous Materials Certification Study Guide 2 Definition of Terms (continued) Static Electricity - Electricity present on a surface.
Bi-Weekly Safety Meeting November 29, The days of using canaries in mines as primitive gas detectors are long gone..they've been replaced by fixed.
Flammable Liquids Directorate of Training and Education
Who are We What do We do How do We do it –Incineration 101 Incinerators vs. Flares Other Choices? Why request an AWI incinerator? –Benefits –Dispersion.
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
Data logging: The term 'data logging' refers to collecting or gathering data over a period of time. How Data is collected? Sensors are used to take readings.
ArsonAnalysis of Fire Arson is defined as purposely setting fire to a house, building or other property. Arson is the second leading cause of death by.
THUM Adapter Impact on Hazardous Area Classification
USING IVMS AS A MANAGEMENT TOOL
General Requirements of NFPA 101
NFIRS 3 Structure Fire Module
Gas Leak Monitoring by Ultrasound
Risk Management Student Powerpoint
Presentation transcript:

Open-Path Gas Detection - Philosophy of Use or The Story of Clouds

2 People who are familiar with point type detectors ask about open-path gas detectors:- How can we know the concentration, at any point, is not above the flammable limit? and The reading will vary with path length. Dont we need to know the length of the path to obtain a true reading of flammability?

3 n These and similar questions may be important for some applications but not for offshore safety. n They do not need to know the path length because they are not interested in the point concentration. n They are not even directly interested in an average measurement - their aim is to detect a significant hazard

4 n In safety applications, gas detection should be used to warn that a hazardous amount of gas might be present in an area. n We are not trying to detect leaks as such because leaks are often not hazardous. n Many leaks will either be too small to threaten safety or may result in flash fires, which can be dealt with by fire hazard management. Generally speaking, gas detection in production areas is aimed at explosion threats/hazards with a general principle that the degree of hazard should never be under-estimated.

5 n Not all gas clouds are hazardous – only if a flammable gas cloud or plume is wide enough to allow flame acceleration to speeds greater than 100m/sec, does it become a significant threat. n Just as an athlete performing the long jump needs a run-up distance, so too a flame front needs distance to reach the velocities which cause the damaging effects of over-pressure, pressure pulse and windage.

6 n This distance is mainly controlled by the confinement and congestion of the area but 5 metres diameter is typical of offshore plant (less in some areas and more in others). n If a gas cloud of this size were at stoichiometric concentration (about 2 x the LEL of the gas) - then ignition could lead to the consequences we are keen to avoid. Although detection of small releases would be nice, it is not critical to safety if some are missed - the aim must be to detect ANY cloud or plume of significant size.

7 Limitations of point type grid layouts n Traditionally, gas cloud monitoring was achieved by installing many point type detectors, in a 3- dimensional grid formation and correlating their signals. One detector seeing gas would cause a warning, prompting inspection, while a second would cause automatic action.

8 Limitations of point type grid layouts n The grid layout of point type gas detectors achieves the aim of volumetric hazard monitoring provided there are sufficient detectors (a tight enough grid) to give a representative picture of the whole area, but this is rarely the case! n The plume of a significant gas leak can (and has) passed undetected between point detector positions.

9 Limitations of point type grid layouts n There are two problems: 1. Not only has gas to reach the point detectors 2. But it must also do so at a concentration high enough to cause alarms. n This means that the gas must reach a point detector before it dilutes below the alarm level in any wind conditions. (Actually, the ventilation in the area will have been specifically designed to prevent this – by diluting gas as rapidly as possible).

10 Limitations of point type grid layouts n The number of point detectors in an area is limited by the practicalities of installation and maintenance and also by the inherent restriction on the cost-benefit of gas detection, due mainly to lack of an effective action to control explosions. n The number of detectors allowed by these limits is often somewhat less than an ideal grid and designers have many problems trying to site point detectors effectively.

11 Philosophy All leaks result in a plume (or cloud), which is concentrated at source and becomes dilute as it disperses in the airflows in the area. 8 metres Diluted to 15%LEL Open path Point type 5 metres spacing High concentration No point detector reads more than 15%LEL – below alarms A point detector has to be close enough to the source that the gas concentration is still strong enough to be detectable but if too close, the plume will be very narrow and detectors would have to be close together. Open-Path reads 8 x 15%LEL = 1.2 LEL.m = above alarms Here is an open- path detector and some point detectors in a 5m grid layout

12 Philosophy Open-path gas detectors remove this problem. Whether the open-path is close to the source of leak or far away, provided that the whole width of the plume is within the path, will produce a similar response. This is partly due to the way the detector works and because air currents primarily govern the movement of gas in offshore modules – so the plume does not usually spread as it would in free-field flow.

13 Philosophy The challenge for siting gas detectors is to predict where the gas will go, instead of trying to predict where it could leak or collect. On the whole, this is a much easier task – the gas will go with the flow. A great deal of work offshore with video cameras and smoke generators convinced the offshore oil companies that the old notion of light gases rising and heavy gases falling is not likely for gaseous releases. Local air movements have the only detectable effect. (Flashing liquid releases are an exception, while they remain cold) Airflows that carry the gas tend to be concentrated in the open, unobstructed areas of the plant, just the right sort of area to install open-path detectors

14 Open-path measurement range n Remember we discussed the 5 metres diameter plume/cloud re flame front velocities and a gas cloud of this size at stoichiometric concentration (about 2 x the LEL) being the limit – this would integrate as 10 LEL.metres (2 LEL x 5m). n For safety margins on the open-path gas detectors full scale range, we halve this to LEL.metres with alarms normally set at 20% and 60% of this scale (equiv 1 & 3 LEL.m resp.). n Safeye even has the sensitivity for certain distances to be set at LEL.m full scale

15 The Result n Open-path gas detectors offer the way forward to good coverage for a justified cost. n The use of the point detector grid approach can be limited to congested areas while open-path detectors monitor the major airflows. n The reduction in the number of devices, cabling, support equipment and maintenance is substantial in most plant.