Common Mistakes by Carrie Schroeder. Emission Factors Where did they come from? How old are they? If you changed it in your spreadsheet, make sure to.

Similar presentations


Presentation on theme: "Common Mistakes by Carrie Schroeder. Emission Factors Where did they come from? How old are they? If you changed it in your spreadsheet, make sure to."— Presentation transcript:

1 Common Mistakes by Carrie Schroeder

2 Emission Factors Where did they come from? How old are they? If you changed it in your spreadsheet, make sure to change it in Redbud Document where you got the emission factor 2

3 Control Efficiencies Is yours included in the emission factor youre using? Then dont forget to check the box! 3

4 Controls Listing controls and efficiencies that do not apply to that pollutant Fabric filters and baghouses only control PM Catalytic converters control CO, VOCs and/or NOx Catalytic oxidizers control CO and VOCs 4

5 Units Double check that the units in Redbud are still accurate Check: process rate units emission factor units We cant replicate your emissions if the units are incorrect 5

6 Hazardous Air Pollutants (HAPs) Are they in your VOCs? Speciate your HAPs out of your VOCs We especially saw this error on compressor engines 6

7 Stack Parameters If flow rate = 0 then list the unit as a fugitive Cannot replicate flow rate and gas exit velocity calculation 7

8 Stack parameters Equation: Gas Exit Velocity = flow rate (acfm) ÷ ( x r 2 x 60) OR Flow rate (acfm) = exit gas velocity x ( x r 2 x 60) acfm= actual cubic feet per minute For non-round stacks Diameter = 1.128 x (length x width) 8

9 Stack Parameters OR 9

10 Reporting/Not Reporting Emissions reported but have 0 for process rate and/or 0 for annual hours OR Process rate reported and/or annual hours reported but emissions are 0 and trace boxes are not checked 10

11 Reporting Same Values If you have the same annual process rate, annual hours, and emissions for 2 years in a row then you will get flagged in our QC program Usually incorrect, so please dont just re- enter last years data Some correct situations might be emergency generators, fire pumps, and process tank heaters 11

12 Inconsistent Increase/Decrease in Emissions You will get flagged if: Annual process rate and hours vary slightly from previous year to current year, but emissions decrease or increase greatly And calculation method, controls, emission factor, and emission factor units have not changed If you legitimately fall into this situation then please make an emission unit note explaining why 12

13 Why Your Inventory Is Important Missing or incorrect release point data lead to errors in geographical location of emissions and impacts photochemical modeling and health risk assessments Missing or incorrect hours and season fractions lead to errors in temporal distribution of emissions Errors in SCC and SIC impact control strategy development and attainment plans Missing or incorrect control equipment data impacts rule development Good data leads to effective air quality regulation 13

14 Any Questions? 14