Flammable and Combustible Liquids

Slides:



Advertisements
Similar presentations
OSHA Most Frequently Cited Serious Violations
Advertisements

Unit B: Safety in Agricultural Mechanics
OSHA Office of Training and Education
Fire Safety and Prevention
HAZARD COMMUNICATION REQUIREMENTS Site Specific Written Program Chemical Inventory MSDSs/SDSs Labeling Non-routine Tasks Contractors Training.
Storage of Flammable and Combustible Liquids
Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Storage of Flammable Liquids
BLR’s Safety Training Presentations
FLAMMABLE AND COMBUSTIBLE LIQUIDS
Understanding Its Causes
Flammable and Combustible Liquid & Compressed Gas Handling and Storage
FLAMMABLE AND COMBUSTIBLE LIQUIDS
2.01 Understand safety procedures
Hazardous Materials Subpart H.
Module 9 Confined Space.
Fire Protection and Prevention New England Roofing Industry Partnership.
© BLR ® —Business & Legal Resources What’s the Big Deal? Flammable and combustible liquids: Are easily ignited and ignite with explosive force Burn.
Resource Conservation and Recovery Act.
Fire Safety. The Stats Fire death statistics throughout the united states –2.1 Million Fires Reported Per Year –5,100 Average Civilian Deaths.
Safe Handling of Flammable and Combustible Liquids
Spray Finishing Operations/Spray Booth March 9, 2009.
1 Flammable and Combustible Liquids INSY 3020 Spring 2006.
Flammable and Combustible Liquids. Flammable liquids v Class I - liquids have flashpoints below 100 degrees F, with vapor pressures not exceeding 40 psia.
Flammable and Combustible Liquids. Flammable liquids Class I - liquids have flashpoints below 100 degrees F, with vapor pressures not exceeding 40 psia.
1 Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Fire Triangle In order to understand how fire extinguishers work, you first need to know a little bit about fire. Four things must be present at the same.
Liquid Fuel Safety Cummins Southern Plains, Ltd..
Laboratory Safety-Flammable Liquids Flammable Liquids and Fire Codes for Laboratories.
FLAMMABLE AND COMBUSTIBLE LIQUIDS
Copyright © Flammable & Combustible Liquids.
Standard 29 CFR Part Flammable & Combustible Liquids.
WFU Explore this site Turn in Safety “Quiz” by Monday. Must make an 80%.
Flammable and Combustible Liquids
Flammable and Combustible Liquids Presented by Martina Schmeling Adapted From OSHA.
HAZARDOUS MATERIALS. OSHA Office of Training and Education - Revised by TEEX 12/05/07 2 Terminal Objective Describe the hazards and requirements of working.
Fire Safety. Fire Safety Introduction Fires ravage 28,000 industrial facilities each year, causing $596 million in direct property damage. Ninety percent.
Fire Prevention for Construction. Four classes of fires  A, B, C, and D 1a.
Safety Training Presentation
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
3.7.3 Student Book © 2004 Propane Education & Research CouncilPage Identifying Safe Handling Practices for Flammable and Combustible Liquids Injecting.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
FLAMMABLES. 1. PROPERTIES OF FLAMMABLES Combustion (redox) reactions Solids, gases, most commonly liquids Fire Tetrahedron Ignition sources External-
Hazardous Materials CFR Safety & Health Consultation.
Army Aviation Support Facility #1 Phoenix, Arizona
FLAMMABLE AND COMBUSTIBLE LIQUIDS 1 Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) OSHA 29CFR PPT
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
Flammable and Combustible Liquids Standard 29 CFR Part City of Council Bluffs Presented by: SilverStone Group © 2006, 2012 Zywave, Inc. All rights.
Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization.
Flammable Liquids Directorate of Training and Education
Safe Handling of Flammable and Combustible Liquids.
Fire Loss Control - Basic Elements
Safe Handling of Flammable and Combustible Liquids
Flammable and combustible liquids
Flammable and Combustible Liquids
Fire protection and prevention
Chemical Transfer.
مایعات قابل اشتعال و احتراق پذیر
Fire Prevention Safety Department
Hazardous Materials Subpart H.
Flammable & Combustible Liquids
Safe Handling of Flammable and Combustible Liquids
Flammable and Combustible Liquids
Flammable and Combustible Liquids
Spray Booths Follow safe operating instructions
Flammable and Combustible Liquids
Flammable and Combustible Liquids
Presentation transcript:

Flammable and Combustible Liquids This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target audience, this presentation emphasizes hazard identification, avoidance, and control – not standards. No attempt has been made to treat the topic exhaustively. It is essential that trainers tailor their presentations to the needs and understanding of their audience. This presentation is not a substitute for any of the provisions of the Occupational Safety and Health Act of 1970 or for any standards issued by the U.S. Department of Labor. Mention of trade names, commercial products, or organizations does not imply endorsement by the U.S. Department of Labor. OSHA Office of Training and Education

OSHA Office of Training and Education Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids requires the use of approved equipment and practices per OSHA standards 29 CFR 1910.106 OSHA Office of Training and Education

OSHA Office of Training and Education Flash Point Flash point means the minimum temperature at which a liquid gives off enough vapor to form an ignitable mixture In general, the lower the flash point, the greater the hazard Flammable liquids have flash points below 100oF, and are more dangerous than combustible liquids, since they may be ignited at room temperature Combustible liquids have flash points at or above 100oF Although combustible liquids have higher flash points than flammable liquids, they can pose serious fire and/or explosion hazards when heated 1910.106(a)(14) Flash point means the minimum temperature at which a liquid gives off vapor within a test vessel in sufficient concentration to form an ignitable mixture with air near the surface of the liquid. Flammable liquids themselves will not burn, but as the liquid evaporates, it gives off vapors that mix with the air to form dangerous gases that can be set off by a small spark. Gasoline, for example, evaporates at temperatures as low as 45 degrees Fahrenheit below zero. As the temperature rises, the rate of evaporation increases and more and more vapors are given off. Flammable vapors are usually heavier than air so they collect in the lowest areas they can reach. Without good ventilation to dissipate them, a small spark can set off a big disaster. OSHA Office of Training and Education

Classes of Flammable and Combustible Liquids 200 IIIA 140 Combustible (FP > 100oF) II Flash Point (oF) 100 IC Flammable (FP < 100oF) 73 IA IB 1910.106(a)(18) and (19) Flammable and combustible liquids are classified primarily according to their flash point to indicate the danger they pose as a fire hazard. Flash point is directly related to a liquid’s ability to generate vapor. Since it is the vapor of a liquid, not the liquid itself, that burns, vapor generation becomes a primary factor in determining the fire hazard. Flammable liquids have flash points below 100oF and are classified as Class I liquids. Flammable liquids are sub-divided into three subclasses: IA, IB, and IC. Class IA liquids have flash points below 73oF and boiling points below 100oF. Class 1B liquids have flash points below 73oF and boiling points at or above 100oF. Class IC liquids have flash points at or above 73oF and below 100oF. Combustible liquids have flash points at or above 100oF and are classified as Class II and Class III liquids. Class II liquids have flash points at or above 100oF and below 140oF. Class III liquids are sub-divided into two subclasses: IIIA and IIIB. Class IIIA liquids have flash points at or above 140oF and below 200oF. Class IIIB liquids have flash points at or above 200oF, and are not regulated by 1910.106. 100 Boiling Point (oF) OSHA Office of Training and Education

Classes of Some Flammable Liquids Common Name Flash Point (oF) CLASS IA CLASS IB CLASS IC Ethyl Ether -49 Gasoline -45 Methyl Ethyl Ketone 21 Toluene 40 Xylene 81-115 Turpentine 95 Other common flammable and combustible liquids and their flash points are shown below: Flash Point (oF) CLASS IA Pentane < -40 CLASS IB Acetone 0 VM&P Naptha 20-45 (Typical) Ethyl Alcohol 55 CLASS IC Mineral Spirits 85-110 CLASS II Fuel Oils 100-130 Kerosene 110-150 CLASS III Ethylene Glycol 232 OSHA Office of Training and Education

OSHA Office of Training and Education Program Components A good plan for safe use of flammable and combustible liquids contains at least these components: Control of ignition sources Proper storage Fire control Safe handling OSHA Office of Training and Education

OSHA Office of Training and Education Sources of Ignition Must take adequate precautions to prevent ignition of flammable vapors. Some sources of ignition include: Open flames Smoking Static electricity Cutting and welding Hot surfaces Electrical and mechanical sparks Lightning 1910.106(e)(6)(i) OSHA Office of Training and Education

OSHA Office of Training and Education Static Electricity Generated when a fluid flows through a pipe or from an opening into a tank Main hazards are fire and explosion from sparks containing enough energy to ignite flammable vapors Bonding or grounding of flammable liquid containers is necessary to prevent static electricity from causing a spark Static electricity can be generated by the contact and separation of dissimilar materials. For example: belts and pulleys, tires and the road, fluid flow through a pipe, agitation and mixing of fluids, and splash filling of flammable liquids. For more information, see NFPA 77, Static Electricity. One of the primary means of reducing the hazard of static electricity when transferring flammable liquids into/from containers is through the use of bonding and grounding, which is discussed in this program. OSHA Office of Training and Education

OSHA Office of Training and Education Bonding Physically connect two conductive objects together with a bond wire to eliminate a difference in static charge potential between them Must provide a bond wire between containers during flammable liquid filling operations, unless a metallic path between them is otherwise present 1910.106(e)(6)(ii) Both objects bonded share the same charge and have no potential difference, BUT there still is a potential difference between the conductive objects and ground. Thus, there is danger of a spark from one of the conductive objects to grounded objects. OSHA Office of Training and Education

OSHA Office of Training and Education Grounding Eliminates a difference in static charge potential between conductive objects and ground Although bonding will eliminate a difference in potential between objects, it will not eliminate a difference in potential between these objects and earth unless one of the objects is connected to earth with a ground wire 1910.106(e)(6)(i) Both objects bonded and grounded permit charge to flow to ground. OSHA Office of Training and Education

OSHA Office of Training and Education Ventilation Always provide adequate ventilation to reduce the potential for ignition of flammable vapors. 1910.106(a)(31) Ventilation for the prevention of fire and explosion is considered adequate if it is sufficient to prevent accumulation of significant quantities of vapor-air mixtures in concentration over one-fourth of the lower flammable limit. For additional information on ventilation, see OSHA’s web site at: http://www.osha-slc.gov/SLTC/ventilation/index.html OSHA Office of Training and Education

OSHA Office of Training and Education Storage Fundamentals Identify incompatible chemicals – check the Material Safety Data Sheet Isolate and separate incompatible materials Isolate by storing in another area or room Degree of isolation depends on quantities, chemical properties and packaging Separate by storing in same area or room, but apart from each other OSHA Office of Training and Education

Storage of Flammable and Combustible Liquids Storage must not limit the use of exits, stairways, or areas normally used for the safe egress of people In office occupancies: Storage prohibited except that which is required for maintenance and operation of equipment Storage must be in: closed metal containers inside a storage cabinet, or safety cans, or an inside storage room Inside storage room 1910.106(d)(5)(i) and (iii) In office occupancies, the inside storage room must not have a door that opens into that portion of the building used by the public. OSHA Office of Training and Education

Safety Cans for Storage and Transfer Approved container of not more than 5 gallons capacity Spring-closing lid and spout cover Safely relieves internal pressure when exposed to fire 1910.106(a)(29) OSHA Office of Training and Education

OSHA Office of Training and Education Flame Arrester Screen Prevents fire flashback into can contents Double wire-mesh construction Large surface area provides rapid dissipation of heat from fire so that vapor temperature inside can remains below ignition point OSHA Office of Training and Education

OSHA Office of Training and Education Storage Cabinets Not more than 60 gal of Class I and/or Class II liquids, or not more than 120 gal of Class III liquids permitted in a cabinet Must be conspicuously labeled, “Flammable - Keep Fire Away” Doors on metal cabinets must have a three-point lock (top, side, and bottom), and the door sill must be raised at least 2 inches above the bottom of the cabinet 1910.106(d)(3)(i) and (ii) and (ii)(a) Three-point lock on metal cabinet doors prevents buckling, which would expose contents to fire. Raised door sill contains leaks. OSHA Office of Training and Education

OSHA Office of Training and Education Fire Control Suitable fire control devices, such as small hose or portable fire extinguishers must be available where flammable or combustible liquids are stored Open flames and smoking must not be permitted in these storage areas Materials which react with water must not be stored in the same room with flammable or combustible liquids 1910.106(d)(7)(i) and (iii) and (iv) OSHA Office of Training and Education

Transferring Flammable Liquids Since there is a sizeable risk whenever flammable liquids are handled, OSHA allows only four methods for transferring these materials: Through a closed piping system From safety cans By gravity through an approved self-closing safety faucet By means of a safety pump 1910.106(e)(2)(iv)(d) Transferring of flammable liquids by means of air pressure on the container or portable tanks is prohibited. OSHA Office of Training and Education

Self-Closing Safety Faucet Bonding wire between drum and container Grounding wire between drum and ground Safety vent in drum OSHA Office of Training and Education

OSHA Office of Training and Education Safety Pump Faster and safer than using a faucet Spills less likely No separate safety vents in drum required Installed directly in drum bung opening Some pump hoses have integral bonding wires OSHA Office of Training and Education

OSHA Office of Training and Education Waste and Residue Combustible waste and residue must be kept to a minimum, stored in covered metal receptacles and disposed of daily. 1910.106(e)(9)(iii) Waste drum with disposal funnel Safety disposal can Oily-waste can (self-closing lid) OSHA Office of Training and Education

Safe Handling Fundamentals Carefully read the manufacturer’s label on the flammable liquid container before storing or using it Practice good housekeeping in flammable liquid storage areas Clean up spills immediately, then place the cleanup rags in a covered metal container Only use approved metal safety containers or original manufacturer’s container to store flammable liquids Keep the containers closed when not in use and store away from exits or passageways Use flammable liquids only where there is plenty of ventilation Keep flammable liquids away from ignition sources such as open flames, sparks, smoking, cutting, welding, etc. Spills or Leaks First, eliminate all sources of ignition, then Stop the leak, if possible Contain the material Isolate the area Avoid direct contact with the material Use appropriate fire control procedures OSHA Office of Training and Education

OSHA Office of Training and Education Summary The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids requires the use of approved equipment and practices per OSHA standards An excellent reference on this topic is National Fire Protection Association Standard No. 30, Flammable and Combustible Liquids Code OSHA Office of Training and Education