CIGRE SC B5 COLLOQUIUM CALGARY

Slides:



Advertisements
Similar presentations
SDG&E PI-based Substation Real-Time Condition Based Maintenance System
Advertisements

Advanced Power Protection Lecture No.2
GENERATOR PROTECTION.
1 Distributed Generation and Power Quality. 2 Relaying considerations DG infeed may reduce the reach of overcurrent relays –DG feeds fault, so utility.
CIGRE 7-10 September 2009, Moscow
DECLERCQ Jan BE Alpha 4 – Block 2 Barcelona May TRANSFORMERS FOR WIND TURBINES NEED FOR NEW DESIGNS OR BUSINESS AS USUAL Dr. Jan Declercq.
Slide 1 UNCLASSIFIED Breaker Operation Arc Flash Breakout Group EFCOG Electrical Safety Workshop – July 18, 2014.
Name: Osamu TSUBOI Country: Japan Registration No.: Group: B5 Pref. Subject: 1 Question: 7 1 Question 7 Non-harmonic-restraint schemes applied in Japan.
15 September 2005 Calgary, Canada
Transformer Construction
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Basic Electricity.
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
Transformer Asset Management
Transformer.
POWER SYSTEM PROTECTION
Transformer Taking the ratio of the two equations
SC-B5 Colloquium Calgary 2005 CIGRE SC B5 COLLOQUIUM CALGARY Contribution to PS2 – Q#2 Contribution to PS2 – Q#2 What are the experiences in utilities.
Power Quality Impacts of Distributed Generation Roger C. Dugan Sr. Consultant Electrotek Concepts, Inc. Tennessee Tech. February 9, 2004.
Protection & Switchgear
Transformer Protection Over-current protection in the form of fuses may be the only protection provided to a small 100 kVA, 11 kV/440 V distribution transformer.
Power Plant Construction and QA/QC Section 4.3 – Electrical Interconnections Engineering Technology Division.
1 Distributed Generation and Power Quality-Continued.
What is POWERGRID??? The Power Grid Corporation of India Limited (POWERGRID), is an Indian state-owned electric utilities company headquartered in Gurgaon,
A Presentation On 132 KV GSS BEHROR
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
ABOC/ATC days Electrical Network: Selectivity and Protection Plan José Carlos GASCON TS–EL Group 22 January 2007.
SC-B5 Colloquium Calgary 2005 CIGRE SC B5 COLLOQUIUM CALGARY Contribution to PS2 – Q#1 How does the specification team value this user input and rank prioritization.
Submitted To:- Submitted By:- Mr.
CIGRE Study Committee B5 Colloquium September 2005, Calgary, Canada PS1 - Question 7 What would be the future practice for selecting harmonic restraint.
HIMACHAL PRADESH STATE ELECTRICITY BOARD LTD.
Circuit Breaker Pictures
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Protection of Power Systems
By, Rakesh Das B.P.E-4 th yr. Roll No th August’ 2011.
Outage of Generator Transformer due to High DGA. BRIEF HISTORY 200 MVA 400 kV GT erected at site. After satisfactory pre-commissioning checks GT was successfully.
Md.Hamidul Haque ID: Prog:BSEEE SEC:E/3 International University of Business Agriculture and Technology (IUBAT )
Basic Transformer Protection Steve Rainwater Energy System Operations Trainer (LCRA)
Design a protection System of 220/33kV Grid Station United Arab Emirates University College of Engineering Saif Mohammed AL Aryani Ahmed Soruor.
TESTING AND MAINTENANCE OF POWER TRANSFORMER
Protection and Relay Schemes
PS 1 – Transformer Protection, Monitoring & Control
Motor Protection Dr. Hendro Rijanto.
Government Engineering College Rajkot
- Condensate pump and feed pump trip!
2004 Cigre SCB5 Session Preferential Subject 3
Protection Relay Testing
Testing of Transformers
MEDIUM VOLTAGE APPLICATIONS.
A presentation on Measurement of Winding Resistance and Insulation Resistance of 3 Phase 11 kV/ 433 V, 16KVA Oil cooled type Transformer PRESENTED BY:
2017 Fall Educational Forum Bruce A. Tagg, ALCM
A transformer is a complex protective object
Birla Vishvakarma Mahavidyalaya (Electrical department) Topic:- Laboratory setup for Numerical Protection of transformer Group No. : 17 Sr no. Name Enrolment.
DESIGN OF DC MACHINES AND TRANSFORMER. ACTIVE LEARNING ASSIGNMENT: VARIOUS PROTECTIVE AND INDICATIVE INSTRUMENTS. PREPARED BY : JOBIN ABRAHAM.
Removal of Fraser RAS from RAS Databse
Chapter 7 System Protection
Protection Philosophy
UNIT II APPARATUS PROTECTION.
ELECTRICAL POWER-II Electrical engineering sixth semester
Presented to: IEEE-IAS (Atlanta) Presented by: Michael D. Seal, P.E.
Transformer Impedance
OIL DISTRIBUTION TRANSFORMERS OIL DISTRIBUTION TRANSFORMERS Presented By 1 Dr. Eng. Adel Abdel-Twab Farag.
Agenda Introduction of Protective Relays
Power System Protective Relaying-Part One
EUS 260 Capstone Project.
The Safe Use of Electricity
- Condensate pump and feed pump trip!
Removal of Fraser RAS from RAS Databse
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
Presentation transcript:

CIGRE SC B5 COLLOQUIUM CALGARY Contribution to PS1 – Q#8 What are the issues that are refraining protection engineers from using additional available protection functions ? What is the present practice of utilities when multifunction relays are applied for protecting transformers ? Florin Balasiu, Transelectrica Romania

AT-200 MVA Protections

Transformer Protection Functions Usually the following protection functions are used: 1. Technological protection Buchholz relay main tank and LTC, direct trip, ER in 87T Oil flow relay Pressure relief devices 2. Differential protection 1 Instantaneous differential Percentage restraint differential – second harmonic blocking Thermal overload, without top oil temperature 3. Differential protection 2 4. Distance protection HV (220 kV)- 21, 50/51, 67N, ER, DR 5. Distance protection LV (110 kV) - 21, 50/51, 67N, ER, DR

Transformer Monitoring Monitoring applied to transformers – separate device HV&LV voltages and currents HV&LV windings temperature Core temperature Oil temperature Pumps and fans Online DGA HV&LV bushings LTC monitoring

Transformer Protection Functions Examples of not used protection and monitoring functions : Over-voltage, except some distribution transformers Over-current, except distribution transformers Over-excitation (U/f>) Negative-sequence Restricted earth-fault Measured values, except commissioning and maintenance Circuit breaker contact wear monitoring

Why ? Why not using additional protection and monitoring functions? Tradition on clear separation between protection (protection engineer task) and monitoring (manufacturer task) Some functions included in other devices (measurement, CB monitoring) Doubt on proper setting calculations Complexity of additional settings Too many protection functions could decrease security