Report # Pit Discovered During Overhaul Report Number: Report Date: 07/14/ :29.
Advertisements

Report Exploding Ammo Hits FFs TOG and Apparatus. Report Number: Report Date: 02/24/ :51.
Report Air Line Connection Failure Report Number: Report Date: 07/13/ Synopsis Equipment misuse leads to injuries.
Report # Downed powerline inhibits fire attack. Report Number: Report Date: 11/13/ :35.
Report Exploding Ammo Hits FFs TOG and Apparatus. Report Number: Report Date: 02/24/ :51.
Emergency Preparedness and Response
Home Fire Hazard Inspections. What we will learn today We will learn how to keep our homes and families safer by conducting home inspections to find the.
Safety Officer State Practical Skill Final Exam. Create a Incident Safety Plan State Practical Skill Exam Using the Structure Fire Safety Report complete.
South Old Bridge Vol. Fire Co. Standard Operation Procedures for Hazardous Material Incidents.
GENERAL SAFETY GUIDELINES IN THE TRANSPORTATION TECHNOLOGY SHOP.
Apparatus Assignments Presentation January 24, 2011.
May 2014 MCO Training:.  Session:  2 Hours  30 minutes class  2 Practice drills  Objectives:  Review RIC and Mayday procedures  Introduce the default.
THE INTERNATIONAL SOCIETY OF FIRE SERVICE INSTRUCTORS Electronic INSTRUCT-O-GRAM Program The “Safety Engine” Concept – Part 1.
Unit: Oxy-Acetylene; Welding, Brazing, Cutting & Heating
Oxygen/ Fuel Cutting and Welding By Ryan Saucier.
Oxygen/ Acetylene Cutting & Safety By Keith Dover.
Transport Railways Incident Procedures. Aim To give students information about the emergency procedures to be adopted at incidents involving railways.
Protecting Evidence Fire Cause Determination. Fire departments should investigate all fires to determine the cause of the fire. The cause of a fire is.
Training On Demand. Purpose To provide fire fighters at an emergency incident a team with pre-assigned duties aimed at rescuing downed, lost or trapped.
Overhaul Operations Henderson Truck Company Manual.
Fire Suppression Techniques IFSTA Chapter 14
21 Fire Suppression. 21 Skill Drill 21-1, Fire Fighter II Coordinating an Interior Attack (1 of 4) 1.Don full PPE, including SCBA. Enter the accountability.
Chapter 18 Lesson Goal After completing this lesson, the student shall be able to identify indicators of an incendiary fire and protect and preserve evidence.
Fire prevention. All fires need fuel, air, and heat to spread 1a.
Fire Risk Assessment.
Rapid Intervention Team & MAYDAY Procedures
Personnel Accountability Purpose: Identify a system of firefighter accountability on site of an incident and account for all firefighters, at any given.
Instructor: Dan Braitsch
L AB S AFETY Please Pay Attention. W ARM U P List 5 classroom expectations that you learned on Tuesday.
Lab Safety The Does and Don'ts.
Safety Training Presentation
Emergency Communication And Evacuation SOP# 505 Training On Demand.
Module 1 : Lesson 1: Working safety in the shop
Lesson Goal After completing this lesson, the student shall be able to identify indicators of an incendiary fire and protect and preserve evidence after.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Identify the unique construction factors of single-family dwellings. Recognize the basic problems.
The Auto Shop and Safety
21 Fire Suppression Skill Drills. 2 Objectives Apply water using the direct, indirect or combination attack. Use a large handline using the one- or two-
Workplace Hazardous Materials Information Systems.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Auto shop safety Safety around the shop. Safety Which characteristic is essential for the professional auto technician? Responsible attitude Knowledge.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Week 8 Seminar Role Of The Company Officer And The Safety Officer.
Part C: Class D Fires and Tactical Considerations.
Automatic Transmissions and Transaxles CHAPTER Automatic Transmissions and Transaxles, 6e James D. Halderman | Tom Birch SIXTH EDITION Copyright © 2015.
MODULE: 5 SALVAGE, OVERHAUL, AND SUPPORT ACTIVITIES.
Revised Spring 2007 Hazard Communication And Your Right - To - Know Dept of Environmental Safety Services.
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
AMC Shop Safety By John Templeton. Objectives Develop safety awareness Practice protective eye care Dress properly for laboratory activities Practice.
Fireground Operations: Structure Fires Union County SOG 3.16.
SAFETY, SECURITY, AND EMERGENCY PLANS IN THE MEDICAL OFFICE Chapter 10, Unit 1.
Ag Engineering I UNIT C: SAFE WORK PRACTICES A. Safety Color Codes 1. Green – safety equipment and first aid supplies 2. Red – fire safety equipment.
Emergency Action Plan What to do in the event of an emergency.
Safety Aspects of Agricultural Mechanics
Hazardous Waste.
Being Ready for the Mayday
Laboratory: Health and Safety Specific Information's
2017 Fire/EMS Safety and Health Week
UNIT-III MAINTENANCE OF SAFETY
FIRE SAFETY & SUPPRESSION
Employee Safety Orientation
Report # Hood Struts Explode Report Number:
Lab Safety Please Pay Attention.
Content Provided by Henderson Truck Company Manual
Metal Window & Door Enclosures
NOVA MANUAL TRAINING TOWNHOUSE June 2009
Oxygen/ Fuel Cutting and Welding
04-21 Fire Police.
OBJECTIVES After studying Chapter 2, the reader should be able to:
Bella Vista Fire Department Procedures on Sprinkled Buildings
Unit 1 Safety Power Mechanics.
Presentation transcript:

Lithium Batteries Explode During Overhaul. Report #12-101 Lithium Batteries Explode During Overhaul. Report Number: 12-101 Report Date: 04/03/2012 21:14 Synopsis Lithium Batteries Explode During Overhaul.

Event Description Fire companies responded to a rural incident for a fully involved barn and shed fire threatening a garage and home. The first due engine arrived with six firefighters staffing a 1500/1000 engine. Command and accountability was established with that engine until an assistant chief arrived and assumed command. The chief arrived and placed his vehicle on the “Charlie” side and assumed the exposure protection and “Charlie” side operations. The second due engine with four firefighters staffing a 1500/1000 arrived and supplied the first due engine. Automatic aid departments arrived and a water point/shuttle was established. Several oxy/acetylene welding tanks were removed and placed on the Alpha operational area. The barn and shed area contained seven farm tractors; some were antiques in the process of restoration. Four of these tractors were on fire and the large farm tires were freely burning along with the fuel in the tractors. The fire was knocked down, crews were rotated and two automatic aid engines were returned to service. The fire investigation began simultaneously with overhaul. The barn contained a shop and an office. The shop area contained paint and solvents along with a lift and associated mechanical tools. The Bravo side wall had burned through and egress to the office area was made from that side. (cont’d.) #12-101

#12-101 …Crews had extinguished the garage adjacent to the Bravo side of the barn which had ignited due to radiant heat and convection. The heat had melted the siding and ignited the soffit and fascia and traveled into the garage. There was a 12' distance between the two buildings. It was in this area that the incident occurred. Four 1.75" lines had been stretched along with a 2.5" blitz. The A/B exposure had two lines as did the A/D side with the 2.5" positioned Alpha center. The barn was 30' by 60' with a shed overhang on three sides. Crews were operating in full PPE and on air during overhaul. The A/B crew of three was operating in the office area on the Bravo side. One firefighter had a 6' NY style hook and two were carrying/dragging a four-drawer metal filing cabinet to access a work bench area with hot spots. The filing cabinet was placed in the area between the barn and the garage. Crews returned to extinguish the hot spots while a second crew stood by with a 1.75" line. The first crew returned to the area between the two buildings and noticed that the contents of the second drawer of the file cabinet were burning. The drawer was opened and the papers were extinguished. (cont’d.)

#12-101 …At that time a firefighter opened the top drawer of the cabinet and turned to say something to the second firefighter with the line. There was an explosion and all three firefighters left the area immediately along with the backup crew. The IC was positioned on the Alpha side and witnessed the explosion and immediately called for a PAR check. All crews were accounted for. The chief was adjacent to the B/C corner and joined the two engine crews that had been operating in the area of the explosion. The chiefs had discussed hazards with the property owner and no ammunition, reloading supplies, or compressed gasses were in the operational areas. The area was re-entered and it was found that the top of the filing cabinet had been peeled back. The top drawer was 5' from the cabinet and missing the side support and door front. The drawer had contained 12 dog tracking collars. These collars were powered by lithium batteries. The collars were piled on top of each other and stored that way. They were not plugged into a charger. Several collars and collar parts were found 20' behind the B/C corner and two collar buckles were found 10' in the other direction on the Charley side. Firefighters were checked by the Safety Officer and EMS and no injuries occurred.

#12-101 Lessons Learned Crews followed proper procedure, had a back-up line in place, and were in full PPE on air when the explosion occurred. Crews assumed that the office area contained the normal office type contents even though the office was in a barn. The owners had been questioned about hazards by the IC, Safety Officer, and Fire Chief. Numerous tractor batteries were found throughout the barn and shed. Paint and thinners along with other solvents and diesel fuel were present. Crews were operational with the understanding that exposure issues to the gases from the batteries and other associated hazards such as the burning tires presented an extreme health issue. No one had any idea about the lithium batteries. Many of us read the warning labels on batteries about proper disposal. It did not enter anyone’s thought process during overhaul that the batteries may constitute an explosion hazard.

#12-101 Discussion Questions How important a role did wearing proper PPE during overhaul play in this near-miss? 2. What steps can we take to prevent threats from hidden hazards such as this? 3. Does your department have an SOP regarding PPE during overhaul?