POWER DISTRIBUTION & POWER LOSS REDUCTION METHODS

Slides:



Advertisements
Similar presentations
Chapter 12 Transformers. Chapter 12 Transformers.
Advertisements

Concept Design Review (CoDR) Shore Station DC Breaker Cable model Transient Analysis Components.
Transformer.
Plant Utility System (TKK-2210)
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
ABS Ennin, George Coleman, David Dadson & Anthony Ansah
Chapter 2 Transformers.
Unit-3 SUBSTATIONS.
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
Management and Organisation of Electricity Use Electrical System Optimisation Belgrade November 2003.
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
POWER HOUSE.
What is POWERGRID??? The Power Grid Corporation of India Limited (POWERGRID), is an Indian state-owned electric utilities company headquartered in Gurgaon,
Submitted to: Submitted by:
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
A SUMMER TRANNING PRESENTATION ON 400 KV GRID SUB STATION BIKANER
A Presentation On 132 KV GSS BEHROR
General power system. objective Review general energy and power system Application of fundamental knowledge of principal machines, transformer and other.
Submitted to: Submitted by:
SUBSTATION LAYOUT AND ACCESSORIES
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
Distribution Systems-General
SERVICE ENTRANCE EQUIPMENT
ON 400 KV GSS RAISER JAIPUR ROAD ,BIKANER
A Training Presentation On 220 KV GSS CHOMU,JAIPUR
A Training Presentation On 132 KV GSS JAIPUR Submitted in partial fulfillment For the award of the degree of BACHELOR OF TECHNOLOGY Submitted To:- Submitted.
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Submitted To:- Submitted By:- Mr.
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
Protection of Power Systems
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
Electrical Power System
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Instrument Transformer Electrical Measuring Instruments & Instrumentation 3rd SEMESTER ELECTRICAL ENGG.
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
6 Week industrial Training Presentation
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
Auto Transformer Current Flow. Principles of Auto Transformers H X H0/X0.
HNC/D Engineering Science
POWER FACTOR CORRECTION
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
CHAPTER 4 SINGLE-PHASE TRANSFORMER
Sub Station.
Introduction to Electric Power System and A. C. Supply
Effects of Harmonics on Capacitors Electrical System
SUB-STATIONS.
Chapter # 25 Sub-Stations risemark.pbworks.com.
Electric Machine Induction Motor
Power Generation and Distribution
GUJARAT POWER OF ENGINEERING AND RESEARCH INSTITUTE (104)
Electric Machine Introduction
EE6501 POWER SYSTEM ANALYSIS
Basics of electrical engineering
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Overview Key diagram of 220 KV Sub station, Ablowal Cables
Engineering Project Cable Management.
Components of Substation
ELECTRICAL POWER-II Electrical engineering sixth semester
Lesson 11: Transformer Name Plate Data and Connections
EHV Transmission Equipments
Tubas ELECTRICAL NETWORK STUDY
EET 323 – Electrical System Design Lecture 9: Grounding
Electrical Distribution System Basics
Ahmed Kulab Moh. Abed Foaad Al-Habeel
DISTRIBUTION SYSTEMS (Theory) By M A R Uzair Assoc Prof EEE NSAKCET
CHAPTER – 41 A.C. TRANSMISSION AND DISTRIBUTION
Substation Equipment's
DIPLOMA In ELECTRICAL ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING GOVERNMENT POLYTECHNIC COLLEGE, HANUMANGARH Sept A Training Presentation On.
Presentation transcript:

POWER DISTRIBUTION & POWER LOSS REDUCTION METHODS www.Fullinterview.com

CONTENTS Power Distribution System Equipment in Power Distribution Losses in the System Methods of Reducing Losses

POWER DISTRIBUTION Classification of Power Distribution 1. According to type of current a. DC Distribution b. AC Distribution 2. According to construction a. Over head distribution system b. Underground distribution system

3. According to service a. General lighting and power b. Industrial power c. Street Lighting 4. According to number of wires a. Two wire b. Three wire c. Four wire 5. According to scheme of connections a. Radial system b. Ring system c. Inter connected system

CONNECTION SCHEMES OF DISTRIBUTION SYSTEM Radial system: In this system feeders radiate from single sub station and feed the distribution at one end only. Ring system: In this system each consumer is supplied via two feeders. The arrangement is similar to two feeders in parallel on different routes. Inter connected system: In this system the feeder ring is energized by two or more generating stations or sub stations.

POWER DISTRIBUTION AT NFC 132kV MAIN RECEIVING STATION 132kV is step down to 33kV or 11kV over two 3 windings transformer of capacity 20/31.5MVA 132kV/33kV/11kV. The two feeders at 132kV are of 100% capacity An ON LOAD TAP CHANGER (OLTC) which is controlled by automatic voltage regulator to provide a constant secondary voltage of 11kV irrespective of primary incoming feeder voltage in a range of 138.6kV to 99kV.

33kV DISTRIBUTION SYSTEM 33kV is step down to 6.6kV by two 15/20MVA, 33kV/6.6kV transformer. The step down secondary voltage is connected to the switch board through a closed type bus duct 6.6kV switch board as 20 bulk oil circuit breaker to feed the 1250kVA, 6.6kV/433V transformer. 11kV DISTRIBUTION SYSTEM 11kV supply from 20/31.5MVA transformer is drawn to the switch panel through XLPE cables. SF6 gas circuit breaker

CAPTIVE POWER GENERATION PLANT (CPGP) Maximum demand of NFC made with APTRANSCO is 10MVA. Total capacity of 7.5MVA, consisting of 3 DG sets, each of 2.5MVA capacity. DG sets are connected to an 11kV bus of the power plant which is linked with the 11kV with board of MSDS-1 over to full capacity feeders. Every production unit is provided with a diesel generator set of capacity 40kVA or 180kVA or 500kVA according to their emergency demand.

EQUIPMENT IN POWER DISTRIBUTION Bus bars: Bus bars or buses are conductors to which several local feeders or sources are connected. 1. Outdoor Bus bars 2. Indoor Bus bar 3. Compound Immersed Bus bar Various types of bus bar arrangements: Single Bus bar Arrangement Duplicate Bus bar Arrangement Sectionalization of Bus bar Ring Bus

Circuit breakers: Circuit breaker requires the separation of contacts in a presence of a dielectric medium which serves two functions as 1. It extinguishes arc between two contacts. 2. Provides adequate insulation between the contacts and from each contact to earth. Classification of Circuit Breaker: 1. Air Circuit Breakers 2. Oil Circuit Breakers 3. SF6 Circuit Breakers

Surge Arresters: Surge arresters are used to protect the apparatus insulation from lightning surges and switching surges. Surge arresters are usually connected between phase and ground in distribution system; near the terminals of the large medium voltage machines and in HV, EHV, HVDC substations. Two types of Surge Arresters: 1. Gapping Silicon Carbide Surge Arresters 2. Zinc Oxide Gapless Arresters.

EQUIPMENT IN POWER DISTRIBUTION S.No Equipment Functions 1 Bus bars Incoming and outgoing circuits are connected to bus bars 2. Lightening arrestors To discharge lightning over voltages and switching over voltages to earth 3. Shunt reactor in E.H.V substations To provide reactive power compensation during low loads. 4. Series reactors To reduce the short circuit currents or starting currents. 5. Neutral Grounding Resistor To limit the earth fault currents. 6. Coupling Capacitor To provide connection between high voltage line and line carrier currents equipment.

S.No Equipment Functions 7. Line Trap To prevent high frequency signal from entering other zones 8. Shunt Capacitors To provide compensations to reactive loads of lagging power factors. 9. Power Transformers To step-up or step-down the voltage and transfer power from one A.C voltage to other A.C voltage at same frequency. 10. Series Capacitors Compensation of series reactors of long lines.

LOSSES IN THE POWER DISTRIBUTION Distribution Line Losses Transformer Losses: 1. Core Losses 2. Copper Losses 3. Dielectric Losses 4. Stray Magnetic Losses: Losses due to Harmonics Losses due to low power factor Miscellaneous losses

IMPROVEMENTS IN POWER DISTRIBUTION IN AN INDUSTRY Energy Management System Power Factor Correction High Efficiency Transformers 1. Dry Type Transformer 2. Amorphous Core Type Transformer Lighting

Energy Management System Industrial Energy Management systems are key factors in energy cost conservation. Monitoring and reports Load shedding Load forecasting

Monitoring and Report Monitoring and reports also reveal at what times there were particularly high loads. From here strategies can be developed to avoid such critical situations. Load Shedding Load shedding modules in an energy management system offer the possibility of specifying a "turn-off strategy" which states precisely which consumers may be turned off at all and in which order.

Industrial load forecasting: Load forecasting gives you a preview of your company’s load curve, it stores knowledge about the production processes’ behavior in typical production situations from several hours to several days ahead. Forecasting can be done in three modes: Assistance Mode Semi-automatic Mode Automatic Mode

DRY TYPE TRANSFORMERS Rating ranges from 100 to 20000 KVA They make use of flame-retardant inorganic insulating materials which free these transformers from all restrictions that apply to oil-filled electrical equipment, such as oil-collecting pits, fire walls, fire extinguishing equipment, etc. Dry Type Transformers are installed wherever oil-filled units cannot be used Their efficiency is rated at 99.02%

DRY-TYPE TRANSFORMERS 1,500 kVA High-Efficiency (Copper)   DRY-TYPE TRANSFORMERS 1,500 kVA Standard (Aluminum) High-Efficiency (Copper) Load Factor** 65% 85% Efficiency 98.64% 99.02% 98.47% Temp. Rise (100% load) 150° C 80° C Core Loss 4.3 kW 5.5 kW Conductor Loss 9.1 kW 4.1 kW 15.5 kW 7.1 kW Total Loss 13.4 kW 9.6 kW 19.8 kW 12.6 kW Power Saving – 3.8 kW 7.2 kW First Cost Rs.7lacs Rs.9lacs Cost Premium Rs.2lacs Benefits of Using High-Efficiency Copper-Wound Dry-Type Transformers Electrical Energy Cost Annual Savings Payback Period Rs.2.25/kWh Rs.57000 3.5 y Rs.1.05lacs 1.9 y Rs.3.15/kWh Rs.80000 2.5 y Rs.1.53lacs 1.3 y Rs.4.05/kWh Rs.1lacs 2.0 y Rs.2.1lacs 1.0 y

AMORPHOUS TRANSFORMERS Amorphous Transformer has become well known after "Super amorphous transformer" produced by Hitachi Ltd., Amorphous transformer uses amorphous alloy in the core. Core material is an alloy of Fe,B,Si. Low iron loss, High permeability, Low stress sensitivity

Comparison between important transformer characteristics of amorphous material and grain oriented electrical steel.

Performance of 315kVA and 630kVA 3 phase, demonstration transformers with wound amorphous cores.

POWER FACTOR CORRECTION The input power factor is the real power divided by the apparent power BENEFITS 1. Released System Capacity 2. Reduced Power Losses 3. Voltage Improvement

Thank U