S Sensors and Measurement Methods

Slides:



Advertisements
Similar presentations
Request Dispatching for Cheap Energy Prices in Cloud Data Centers
Advertisements

SpringerLink Training Kit
Luminosity measurements at Hadron Colliders
From Word Embeddings To Document Distances
Choosing a Dental Plan Student Name
Virtual Environments and Computer Graphics
Chương 1: CÁC PHƯƠNG THỨC GIAO DỊCH TRÊN THỊ TRƯỜNG THẾ GIỚI
THỰC TIỄN KINH DOANH TRONG CỘNG ĐỒNG KINH TẾ ASEAN –
D. Phát triển thương hiệu
NHỮNG VẤN ĐỀ NỔI BẬT CỦA NỀN KINH TẾ VIỆT NAM GIAI ĐOẠN
Điều trị chống huyết khối trong tai biến mạch máu não
BÖnh Parkinson PGS.TS.BS NGUYỄN TRỌNG HƯNG BỆNH VIỆN LÃO KHOA TRUNG ƯƠNG TRƯỜNG ĐẠI HỌC Y HÀ NỘI Bác Ninh 2013.
Nasal Cannula X particulate mask
Evolving Architecture for Beyond the Standard Model
HF NOISE FILTERS PERFORMANCE
Electronics for Pedestrians – Passive Components –
Parameterization of Tabulated BRDFs Ian Mallett (me), Cem Yuksel
L-Systems and Affine Transformations
CMSC423: Bioinformatic Algorithms, Databases and Tools
Some aspect concerning the LMDZ dynamical core and its use
Bayesian Confidence Limits and Intervals
实习总结 (Internship Summary)
Current State of Japanese Economy under Negative Interest Rate and Proposed Remedies Naoyuki Yoshino Dean Asian Development Bank Institute Professor Emeritus,
Front End Electronics for SOI Monolithic Pixel Sensor
Face Recognition Monday, February 1, 2016.
Solving Rubik's Cube By: Etai Nativ.
CS284 Paper Presentation Arpad Kovacs
انتقال حرارت 2 خانم خسرویار.
Summer Student Program First results
Theoretical Results on Neutrinos
HERMESでのHard Exclusive生成過程による 核子内クォーク全角運動量についての研究
Wavelet Coherence & Cross-Wavelet Transform
yaSpMV: Yet Another SpMV Framework on GPUs
Creating Synthetic Microdata for Higher Educational Use in Japan: Reproduction of Distribution Type based on the Descriptive Statistics Kiyomi Shirakawa.
MOCLA02 Design of a Compact L-­band Transverse Deflecting Cavity with Arbitrary Polarizations for the SACLA Injector Sep. 14th, 2015 H. Maesaka, T. Asaka,
Hui Wang†*, Canturk Isci‡, Lavanya Subramanian*,
Fuel cell development program for electric vehicle
Overview of TST-2 Experiment
Optomechanics with atoms
داده کاوی سئوالات نمونه
Inter-system biases estimation in multi-GNSS relative positioning with GPS and Galileo Cecile Deprez and Rene Warnant University of Liege, Belgium  
ლექცია 4 - ფული და ინფლაცია
10. predavanje Novac i financijski sustav
Wissenschaftliche Aussprache zur Dissertation
FLUORECENCE MICROSCOPY SUPERRESOLUTION BLINK MICROSCOPY ON THE BASIS OF ENGINEERED DARK STATES* *Christian Steinhauer, Carsten Forthmann, Jan Vogelsang,
Particle acceleration during the gamma-ray flares of the Crab Nebular
Interpretations of the Derivative Gottfried Wilhelm Leibniz
Advisor: Chiuyuan Chen Student: Shao-Chun Lin
Widow Rockfish Assessment
SiW-ECAL Beam Test 2015 Kick-Off meeting
On Robust Neighbor Discovery in Mobile Wireless Networks
Chapter 6 并发:死锁和饥饿 Operating Systems: Internals and Design Principles
You NEED your book!!! Frequency Distribution
Y V =0 a V =V0 x b b V =0 z
Fairness-oriented Scheduling Support for Multicore Systems
Climate-Energy-Policy Interaction
Hui Wang†*, Canturk Isci‡, Lavanya Subramanian*,
Ch48 Statistics by Chtan FYHSKulai
The ABCD matrix for parabolic reflectors and its application to astigmatism free four-mirror cavities.
Measure Twice and Cut Once: Robust Dynamic Voltage Scaling for FPGAs
Online Learning: An Introduction
Factor Based Index of Systemic Stress (FISS)
What is Chemistry? Chemistry is: the study of matter & the changes it undergoes Composition Structure Properties Energy changes.
THE BERRY PHASE OF A BOGOLIUBOV QUASIPARTICLE IN AN ABRIKOSOV VORTEX*
Quantum-classical transition in optical twin beams and experimental applications to quantum metrology Ivano Ruo-Berchera Frascati.
The Toroidal Sporadic Source: Understanding Temporal Variations
FW 3.4: More Circle Practice
ارائه یک روش حل مبتنی بر استراتژی های تکاملی گروه بندی برای حل مسئله بسته بندی اقلام در ظروف
Decision Procedures Christoph M. Wintersteiger 9/11/2017 3:14 PM
Limits on Anomalous WWγ and WWZ Couplings from DØ
Presentation transcript:

S-108.3011 Sensors and Measurement Methods Flow rate measurement S-108.3011 Sensors and Measurement Methods

Why is flow rate measurement needed? Provides knowledge required in industry and municipal engineering Knowing momentary flow rate of gases and liquids Essential for process control, optimization and security Knowing the time integral of a flow rate which is the amount passing through Important to balance calculations in facilities and subprojects Flow rate measurement

Basic concepts of fluid mechanics Flowing can be divided in several different ways Frictionless (ideal fluid) and frictioned flow Laminar and turbulent Compressible and incompressible Important properties of the measured medium: viscosity, temperature, pressure, corrosiveness, solid particles Flow rate measurement

Basic concepts of fluid mechanics Flow rate 𝑞= 𝑑𝑥 𝑑𝑡 Volume flow rate 𝑞 𝑣 =𝑞∙𝐴= 𝑑𝑉 𝑑𝑡 Mass flow rate 𝑞 𝑚 =𝜌 𝑞 𝑣 = 𝑑𝑚 𝑑𝑡 Conservation of energy applied to fluid mechanics is called Bernoulli’s principle: 𝜌𝑔ℎ+𝑝+ 1 2 𝜌 𝑣 2 =constant Volume flow rate continuity: A1v1 = A2v2 Wing of an airplane Flow rate measurement

Basic concepts of fluid mechanics Viscosity 𝜇 represents the internal friction of the material which is generated by velocity gradients in the observed system Force maintaining the velocity gradient 𝑓=𝜇𝐴 𝑑𝑣 𝑑𝑥 𝐴 = area of the intersecting layers 𝑑𝑣 𝑑𝑥 = velocity gradient SI unit of the viscosity Ns/m2 = Pa·s Small viscosity – well running material E.g. viscosity of water: 1.0 mPa·s, lubricating oil: 1000–3000 mPa·s Flow rate measurement

Basic concepts of fluid mechanics Laminar flow Particles move parallel Slower movement on the sides Profile of the flow rate Turbulent flow Turbulence in the flowing material Disturbs several measuring instruments Flow rate measurement

Basic concepts of fluid mechanics Reynolds number = inertial force of mass / viscous force Re= 𝜌 𝑣 𝑠 2 𝐿 𝜇 𝑣 𝑠 𝐿 2 = 𝜌 𝑣 𝑠 𝐿 𝜇 𝑣 𝑠 average flow rate 𝐿 specific length of the flow e.g. diameter of a circular tube 𝜇 viscosity of the flow medium (=friction) 𝜌 density of the flow medium With small Re the flow is laminar The transition from laminar to turbulent flow is indicated with a critical Re Recrit depends on the flow configuration. In a tube, with circular cross section, Recrit = 2300 Flow rate measurement

Meters for pressure difference Most common type of flow rate meters Very suitable for measuring the flow of liquids, gases and steams Can be divided into two classes: Meters based on throttling device Orifice plate Flow nozzle Venturi tube Meters based on stagnation pressure Pitot tube Target flow measurement Flow rate measurement

Throttling device Not wanted quantity! Measured Pr – decrease in total pressure Not wanted quantity! Measured Flow rate measurement

Throttling device Bernoulli’s principle: 𝑝 1 + 1 2 𝜌 𝑣 1 2 = 𝑝 2 + 1 2 𝜌 𝑣 2 2 Continuity of the flow rate: 𝑞 𝑣 = 1 4 𝜋 𝐷 2 𝑣 1 = 1 4 𝜋 𝑑 2 𝑣 2 ⇒ 𝑣 1 = 2∆𝑝 𝜌 𝐷 𝑑 4 −1 𝑞 𝑣 = 1 4 𝜋 𝐷 2 2∆𝑝 𝜌 𝐷 𝑑 4 −1 =𝜋 𝐸𝐷 2 𝛽 2 ∆𝑝 8𝜌 , where 𝐸= 1 1− 𝛽 4 is approaching factor, and 𝛽= 𝑑 𝐷 Flow rate measurement

Throttling devices Orifice Nozzle The most common throttling device inexpensive, plenty of experince using it in practice Can be manufactured from several different materials Also for corrosive materials Not suitable for fluids with large impurities Risk of blocking the flow Nozzle Advantages compared to orifice: Smaller pr Lower risk of blocking the flow Flow rate measurement

Venturi tube Smaller decrease in total pressure than in the case of orifices or nozzles Large size Entry cone taper 30°, exit cone taper 5° Often a shortened version is used (”Dall tube”) expensive Flow rate measurement

V-cone sensor Most recent type, more compact than a venturi tube Flow rate measurement

Stagnation pressure meters An obstacle, which has one end closed, is placed inside a linepipe Inside the tube shaped obstacle, there is a flow rate 𝑣 2 =0 Dynamic pressure i.e. stagnation pressure: 𝑝 2 = 𝑝 1 + 1 2 𝜌 𝑣 1 2 Flow rate: 𝑣 1 = 2 𝜌 ∆𝑝 Flow rate measurement

Pitot tube Measures both dynamic and static pressure caused by a flow In industry, it is used to measure pure liquids and gases. It can also be used to measure the air flow rate of airplanes Flow rate measurement

Target flow measurement A flow applies a force to a target and this force is measured Force applied to target: 𝐹=𝑝𝐴= 1 2 𝑘𝐴𝜌 𝑣 2 𝑘 is the shape factor of the target, 𝐴 is the area of the target Flows going either way can be measured On the other hand, it is sensitive to vibrations and shocks Most suitable for measuring pure liquids and gases Inaccuracy about ± 3 %. Flow rate measurement

Magnetic flow rate measurement An induced voltage 𝐸 is created in a magnetic field due to a conductive liquid moving If the electrodes, magnetic field and the flow channel are perpendicular: 𝐸=𝑣𝐵𝐷 Voltage is small (mV), protection against interference is important Due to electrochemical potentials an alternating magnetic field is used Independent on the density, viscosity, temperature and flow rate profile of the measured liquid Does not contain moving parts → durable Does not disturb the flow Expensive Suitable only for conductive liquids: conductivity > 5 mS/cm Electrodes on the walls Flow rate measurement

Ultrasound: transit time measurement Transit time difference is measured (both forward current and reversed current) Flow rate: 𝑣= 𝑐 2 ∆𝑡 2𝑙 cos 𝛼 The method is suitable for several kinds of flows (even gases), requiring that the speed of sound in this medium is known Temperature dependency Can be built completely outside the channel Flow rate measurement

Transit time measurement Multiplexer channel measurement allows to measure average flow rate during the whole flow channel If the diameter of the flow channel is small, it is difficult to get an accurate result → an arrangement is used, where the ultrasound is parallel with the flow Flow rate measurement

Applying Doppler effect Ultrasound is reflected from bubbles and impurities in the flow Usually less accurate compared to transit time measurement Impurities Flow rate measurement

Vortex flowmeter based on vibration Fixed obstacle causes periodic vortexes Occurrence frequency of the vortexes is directly proportional to flow rate (Reynolds number) Frequency is measured with e.g. piezoelectric force sensor or ultrasound Flow rate measurement

Vortex flowmeter Regular vortexes may form if Reynolds number is 300 – 300 000 Frequency: 𝑓= 𝑆𝑣 𝑑 , where 𝑆 = Strouhal number, 𝑑 = width of the obstacle Reynolds: inertia/friction, Strouhal: frequency/inertia Accuracy is deteriorated for example by contamination, air bubbles, solid impurity particles and change in viscosity Air bubbles in liquid deteriorate the signal-to-noise ratio of detecting Suitable also for measuring low flow rates with inaccuracy even below 1% Using a narrow obstacle causes a small pressure loss Flow rate measurement

Measuring mass flow rate Mass flow rate can be measured with a volume flow rate meter: 𝑚=𝑉𝜌 When a constant density is assumed If the density of the measured medium is not constant or it contains air bubbles, the mass flow rate measured with a volume flow rate meter is not reliable! Flow rate measurement

Coriolis flow meter Directly measures mass flow rate One or two vibrating tubes at inlet and outlet side. Tubes are U-, S-, or W-shaped As the flow goes through the vibrating tube, the tube starts to bend and coriolis force changes the direction at the inlet side Flow rate measurement

Coriolis flow meter Bending depends on the mass flow rate Bending is measured with location sensors Analysis on frequency, phase difference or the amplitude of the flow tube vibration frequency Both velocity and density are got independently! Velocity from the phase difference Density from the frequency Vibration properties are temperature dependent Monitoring temperature during the process Temperature corrections can easily be made Flow rate measurement

Thermic methods Based on a cooling effect of a flow A thin heated wire or film loses part of its heat to a flow Temperature is measured resistively and another sensor measures the temperature of the flow Low response time and high sensitivity Suitable for measuring slow flows Impurities in a flow damage wires Applied to gas flow measurements Flow rate measurement

Cross correlation flow meter Based on measuring the transition time of particles flowing in a channel between two sensors Measuring quantity may be e.g. optical or ultrasound Does not disturb the flow at all! Other quantities are possible too Suitable for measuring solid mediums because there is no need to place additional obstacles to the flowing channel Flow rate measurement

About the accuracy of flow rate measurements Effect of the installation point A flow stabilizes after a long and straigth tube Changes Density (non-uniform material), velocity distribution Electric conductivity Temperature distribution (thermal expansion of the tube) Flow circumstances (roughness of the surface, critical dimensions of the pressure difference instrument) Measured material is always different compared to material used in calibration Pressure variation must be considered in gas measurements Flow rate measurement

Flow rate meters with changing aperture Revision: aperture size of the throttling device is constant in pressure difference meters; flow rate is determined with the pressure difference between the entry and exit side In meters with changing aperture, the pressure stays roughly the same. The flow rate determines the aperture size Flow rate measurement

Rotameter Glass or metal Scale on the wall of a glass tube rotameter, in the case of metal rotatometer scale can be e.g. magnetic Does not require expensive equipment → inexpensive meter Suitable for liquids and gases Also suitable for slow flows Movement of the float must be attenuated if the flow has much variation Floating level sensor Flow rate measurement

Rotameter – the shape of the float The shape of the float strongly affects its propeties: 1. Easy to manufacture → used in small rotameters 2. General float, cone head → very durable 3. For small flows 4. Low sensitivity to viscosity 5. Sensitive to changes in viscosity → used as a viscosity sensor when the flow rate is constant → scale must be produced to each measured material Flow rate measurement

Volume counters Used in flow rate measurements of liquids Good accuracy → Used to calibrate other flow rate meters Trivial example: a bucket and a stopwatch Flow rate measurement

Oval wheel flow meter Oval shaped cogwheels spin due to pressure difference between the entry and the exit side As the cogwheels spins 180°, a volume V1+V2 of liquid has passed through the meter On the negative side: sensitive to impurity particles Error about 0,5 % Flow rate measurement

Mutating disc flow meter Used as household water flow meters Pressure difference between the inlet and the exit side forces a circular disc to nutate A constant volume of liquid passes through the meter during every spin Flow rate measurement

Current meter A rotor which contains as frictionless as possible bearing. A flow forces the rotor to rotate The speed of rotation of the rotor is proportional to flow rate The movement of the current meter is tranferred electrically or mechanically to a counter Flow rate measurement

Turbine meter The most common type of current meters Specific models for gases and liquids Error is in the case of liquids about 0,3 %, and gases 1 % Turbulences may cause an error of several percents Contamination → suitable only for pure flows Fast response time → flow rate can change rapidly Liquid turbine meter (flow straighteners remove turbulences from the flow) Gas turbine meter Flow rate measurement

Blade wheel counter Commonly used in water measurements Flow rate is determined from the speed of rotation Error about 2 % Flow rate measurement