Presentation is loading. Please wait.

Presentation is loading. Please wait.

4 May 20041 I/O Control. 4 May 20042 What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:

Similar presentations


Presentation on theme: "4 May 20041 I/O Control. 4 May 20042 What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:"— Presentation transcript:

1 4 May 20041 I/O Control

2 4 May 20042 What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example: –An input connected to a glass-break detector can be linked to an output connected to an alarm –This means a broken window will sound an alarm

3 4 May 20043 Dedicated I/O Points Certain inputs are automatically dedicated to specific output functions and are not freely programmable – for example: –The Request to Exit (RTE) input drives the door lock output –The door switch input drives the door alarm output

4 4 May 20044 Selectively Dedicated I/O Certain inputs can be selectively dedicated to specific outputs if so desired – for example: –The secondary RTE input can be assigned to also drive the door lock output

5 4 May 20045 Additional I/O Points An SB-593 Satellite board is required to perform any additional programmable I/O operations –The Satellite board provides the additional inputs and outputs needed for programming

6 4 May 20046 Manual Output Control Manual output control allows you to use Doors to select an output from a list and then turn that output On or Off

7 4 May 20047 I/O Control is a Two-Part Process 1.Input/output configuration –Indicate if inputs or outputs are dedicated –Define inputs as normally-open or normally- closed –Assign names 2.Link configuration –Assign inputs to outputs –Define how the outputs respond to input events

8 4 May 20048 Dedicated I/O Reminder The first time you click on the Doors tab during any session, a reminder appears for making the dedicated I/O assignments before making any general I/O control assignments –Ensures dedicated I/O links are protected from improper assignments

9 4 May 20049 Open the I/O Configuration Window Click the button or Select the Setup > System pull-down menu Click the I/O Config tab to open the configuration window

10 4 May 200410 Select Controller Use the pull-down list to locate the controller for which inputs and outputs should be defined

11 4 May 200411 System Dedicated I/O Points System-defined I/O points are grayed out –These are automatically assigned by Doors for specific functions, i.e. Door switch Door lock RTE Alarm output

12 4 May 200412 Assignable Dedicated I/O Points Individual I/O points that can be dedicated to additional functions are identified with Doors defined names, i.e. –DoorB AUX RTE –DoorA DHO alarm out

13 4 May 200413 Assign Dedicated I/O Click in the appropriate Dedicated Y/N check box to make the additional assignments, i.e. –Auxiliary RTE for Door B - Input –Door Held Open for Door A - Output

14 4 May 200414 Save I/O Changes Click the button –If you close the I/O configuration window without saving, your changes are lost and must be reentered

15 4 May 200415 Input Name Assignment Assign a descriptive name to the selected input, i.e. –Glass-Break Sensor Do not duplicate names or descriptions to prevent confusion when printing reports

16 4 May 200416 Select Input State Click on the Mode N/O N/C radio buttons according to whether the input is normally-open or normally- closed

17 4 May 200417 Output Name Assignment Assign a descriptive name to the selected output, i.e. –Glass-Break Alarm

18 4 May 200418 Save Changes Click the button –If you close the I/O configuration window without saving, your changes are lost and must be reentered

19 4 May 200419 Save Changes Reminder If you forget to save the changes, a reminder appears when you attempt to exit the I/O Config window Click the button

20 4 May 200420 Open the Link Configuration Window Click the button or Select the Setup > System pull-down menu Click the Link Config tab to open the configuration window

21 4 May 200421 Select Controller Use the pull-down list to select the controller for which the input to output link should be defined –This can only be a controller with an SB-593 Satellite board

22 4 May 200422 System Dedicated I/O Links System-defined I/O link points are grayed out –These are automatically assigned by Doors for specific functions

23 4 May 200423 Link Name Assignment Assign a descriptive name to the selected input to output link, i.e. –Glass-Break Monitor

24 4 May 200424 Select the Input Select the input to be assigned in this link

25 4 May 200425 Multiple Input Links Multiple inputs can be applied to a link –Select all inputs to apply

26 4 May 200426 Multiple Input Processing Multiple inputs are processed using Boolean logic Select OR or AND depending upon how the output should be driven –OR triggers the output if ANY input generates a signal (input 1 OR input 2 OR input 3, etc.) –AND triggers the output if ALL inputs generate a signal (input 1 AND input 2 AND input 3, etc.)

27 4 May 200427 Select the Output Select the output to be assigned in this link

28 4 May 200428 Set Output Mode Set the output mode for the link – this defines how the output should react when enabled –N – Normal to drive the output to its at rest state –A – Active to drive the output to its active state

29 4 May 200429 Set the Time Zone Select the time zone during which this link will be active –For the I/O link to be made, the input must change state during the time zone period - Input changes made outside of this time zone will not generate the link to the output –If the Input is already active when the time zone begins, the link to the output will not occur

30 4 May 200430 Output versus Event Message An I/O link can be directed to generate an output event message instead of driving an output relay –Click on Enable Outputs to have the input drive the output relay –Click on Event Messages Only to have the input generate an event message

31 4 May 200431 Link Sounds Alert An I/O link can be directed to sound an alert when active –Sound Alerts must be enabled using the Setup > Monitor and Events > Access Messages pull-down menu option –The system must be in monitor mode and the controller must be online for alerts to be annunciated –The Windows™ exclamation WAV file is the sound that plays Click on the Link Sounds Alert box to enable this feature

32 4 May 200432 Output Drive Type There are three output drive options: –Timed – stays active for a defined amount of time When a timed link is triggered by an event, the timer must expire before a new timed link can be triggered (the timed link does not reset if there are rapidly occurring, multiple events) –Follow – follows the state of the input, when the input is active, the output is active –Latched – stays active until manually inactivated Either by another link or via manual output control commands (described later in this presentation)

33 4 May 200433 Timed Output Click on the Timed radio button to enable this option Enter the desired relay active time in seconds

34 4 May 200434 Follow Output Click on the Follow radio button to enable this option

35 4 May 200435 Latched Output Click on the Latched radio button to enable this option

36 4 May 200436 Save Link Changes Click the button –If you close the link configuration window without saving, your changes are lost and must be reentered

37 4 May 200437 Manual Output Control Allows you to remotely activate a controller’s output, controlling an external device Possible examples: –Remote lighting –Siren –Remote gate

38 4 May 200438 Open the Output Control Window Use the Operate > Output Control pull- down menu option

39 4 May 200439 Select Output Controller Click on the Controller pull-down list and scroll through the desired controller

40 4 May 200440 Available Outputs The available outputs are displayed

41 4 May 200441 Turn an Output ON Click the button to turn an output ON The output status is then displayed

42 4 May 200442 Turn an Output OFF Click the button to turn an output OFF The output status is then displayed