1 www.planet.com.tw Industrial Ethernet Solution Copyright © PLANET Technology Corporation. All rights reserved.

2 www.planet.com.tw 2 / 33 Introduction Applications Advantage of PLANET’s Solution Product Features Comparison Roadmap

3 www.planet.com.tw 3 / 33 Applications Factory Redundant Ring Application Designed for Industry – Din Rail, IP30 light/ strong aluminum housing. Right for factory, dusty, unregulated power environment Designed for Industry – Din Rail, IP30 light/ strong aluminum housing. Right for factory, dusty, unregulated power environment Dual Power – Dual power system supports power from 12 to 48VDC Dual Power – Dual power system supports power from 12 to 48VDC

4 www.planet.com.tw 4 / 33 Applications Transportation Networking and Public Wireless Service Full SNMP Management – Full featured SNMP management Redundant Ring – Fast link recovery Full SNMP Management – Full featured SNMP management Redundant Ring – Fast link recovery

5 www.planet.com.tw 5 / 33 PLANET Advantages Base on Ethernet technology  Web/SNMP Full Function Management  Layer 2 Switching Functions on the Network  Ethernet Copper / Fiber Optical Interfaces Designed to operate reliably in electrically and environmentally harsh environments Wide-Range Redundant Power Input Redundant Ring Fast Ethernet Data recovery

6 www.planet.com.tw Product Features

7 www.planet.com.tw 7 / 33 Product Overview Unmanaged Industrial Switch Industrial Media Converter Managed Industrial Switch Managed Industrial Switch ModelDescriptionApplication ISW-1022M 8-Port 10/100 + 2G TP/SFP Fast Fail-over redundancy Fiber back link with ring support ISW-800M 8-Port with Management Back link with fast ring support ISW-802M ISW-802M15 8-Port Management with 2 FX Fast fail-over redundancy Fiber back link with ring support IGS-800M 8-Port 10/100/1000 Management Backbone

8 www.planet.com.tw 8 / 33 Product Overview ModelDescriptionApplication IGS-501 IGS-801 5/8-Port 10/100/1000Entry node for industrial IGS-501T IGS-801T 5/8-Port 10/100/1000Wide Temperature industrial ISW-511 ISW-511S15 4-Port 10/100 + 1 FX Entry node for industrial with Fiber extension ISW-621 ISW-621S15 4-Port 10/100 + 2 FX Entry node for industrial with Fiber extension ISW-500 5-Port 10/100Entry node for industrial ISW-800 8-Port 10/100Entry node for industrial Unmanaged Industrial Switch Industrial Media Converter Managed Industrial Switch Unmanaged Industrial Switch

9 www.planet.com.tw 9 / 33 Product Overview ModelDescriptionApplication IFT-802 IFT-802S30 TP/FX Industrial Converter (Multi-Mode/Single Mode) Fiber extension for tough environment IGT-90x Gigabit TP/FX Industrial Converter Fiber extension for tough environment ICS-210x RS-232/422/485 over Ethernet Converter Serial device long distance deployment Unmanaged Industrial Switch Industrial Media Converter Managed Industrial Switch Industrial Media Converter

10 www.planet.com.tw Features Managed Industrial Switch

11 www.planet.com.tw 11 / 33 Features ISW-1022M Managed Industrial Ethernet Switch A. Hardware Feature Comply with IEEE 802.3, IEEE 802.3u RJ-45 Port support auto MDI/MDI-X function 8K MAC address table 5.6Gbps back-Plane Wide-range redundant power design DIN rail and wall mount design B. Industrial Conformance 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power -10 to 60 Degree C operation temperature IP-30 Aluminum case Relay alarm for port breakdown, power failure EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100- 4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 UL, cUL, CE/EN60950 safety Stability testing with IEC60068-2-32 (Free fall), IEC60068-2- 27 (Shock) and IEC60068-2-6 (Vibration) ISW-1022M (8 Fast Ethernet ports + 2G TP/SFP Combo) IndustrialSNMPFast Ring

12 www.planet.com.tw 12 / 33 Features ISW-1022M Managed Industrial Ethernet Switch C. Switching Feature Rapid Ring function for data redundant, less than 20ms link/data recovery Parid Ring Applications: Coupling Ring Dual Homing 802.1q Tagged VLAN/Port-based VLAN IEEE 802.1p class of service, 4 priority queues IP TOS/DSCP priority IGMP v1/v2 and Query mode 802.1d STP / 802.1w Fast STP Ingress / Egress bandwidth control D. System Web/SNMP/Telnet management System event log support E-mail event alert IP security for illegal access prevention Port mirror transmission monitoring SNMP v1, v2c, v3 and 4 RMON groups

13 www.planet.com.tw 13 / 33 Features ISW-800M/802M/802M15 Managed Industrial Ethernet Switch A. Hardware Feature Comply with IEEE 802.3, IEEE 802.3u CSMA/CD Protocol RJ-45 Port support auto MDI/MDI-X function 2K MAC address table 1Mbit memory buffer 2.0Gbps back-Plane Wide-range redundant power design Store and forward switch architecture DIN rail and 3-way wall mount design B. Industrial Conformance 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power 0 to 60 Degree C operation temperature IP-30 Aluminum case Relay alarm for port breakdown, power failure EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 UL, cUL, CE/EN60950 safety Stability testing with IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock) and IEC60068-2-6 (Vibration) ISW-800M/802M (6/8 Fast Ethernet ports + 2 100Base Fiber) IndustrialSNMPFast Ring

14 www.planet.com.tw 14 / 33 Features ISW-800M/802M/802M15 Managed Industrial Ethernet Switch C. Switching Feature Ring function for data redundant, less than 300ms link/data recovery 802.1q Tagged VLAN/Port-based VLAN IEEE 802.1p class of service, 4 priority queues IGMP v1 and Query mode 802.1d STP / 802.1w Fast STP Ingress / Egress bandwidth control D. System Web/SNMP management System event log support Configuration backup/restore E-mail event alert IP security for illegal access prevention TFTP firmware upgrade Port mirror transmission monitoring

15 www.planet.com.tw 15 / 33 Features IGS-801M Managed 8-Port Gigabit Industrial Switch Hardware Feature Comply with IEEE 802.3, IEEE 802.3u 16G switch fabric RJ-45 Port support auto MDI/MDI-X function Wide-range redundant power design Store and forward switch architecture DIN rail and wall mount design Relay alarm output for power input failure Industrial Conformance -10 to 60 Degree C operation temperature 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power IP-30 metal case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 Stability testing with  IEC60068-2-32(Free fall)  IEC60068-2-27(Shock)  IEC60068-2-6(Vibration) IGS-801M (5/8 10/100/1000 ports) IndustrialSNMPDin Rail

16 www.planet.com.tw 16 / 33 Features IGS-801M Managed Industrial Ethernet Switch C. Switching Feature 802.1q Tagged VLAN/Port-based VLAN IEEE 802.1p class of service, 4 priority queues IP TOS/DSCP priority IGMP Snooping v1/v2 and Query mode 802.1d STP / 802.1w Rapid STP 802.1x Port-based authentication D. System Web management SNMP v1, v2c monitoring and Trap alarm Port mirror transmission monitoring Cable Diagnostic

17 www.planet.com.tw Features Unmanaged Industrial Switch

18 www.planet.com.tw 18 / 33 Features ISW-500/800 5/8-Port Entry Level Industrial Switch Hardware Feature Comply with IEEE 802.3, IEEE 802.3u CSMA/CD Protocol RJ-45 Port support auto MDI/MDI-X function Wide-range redundant power design Store and forward switch architecture DIN rail and 3-way wall mount design Industrial Conformance 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power 0 to 60 Degree C operation temperature IP-30 Aluminum case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 UL, cUL, CE/EN60950 safety Stability testing with IEC60068-2-32(Free fall), IEC60068-2-27(Shock) and IEC60068-2-6(Vibration) ISW-500/800 (5/8 Fast Ethernet ports) IndustrialIP30Din Rail

19 www.planet.com.tw 19 / 33 Features ISW-511 / ISW-621 4+ 1/2-Port 100FX Industrial Switch Hardware Feature Comply with IEEE 802.3, IEEE 802.3u RJ-45 Port support auto MDI/MDI-X function SC single-mode/multi-mode fiber optical interface Wide-range redundant power design Store and forward switch architecture DIN rail and wall mount design Industrial Conformance -10 to 60 Degree C operation temperature 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power IP-30 metal case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 Stability testing with  IEC60068-2-32(Free fall)  IEC60068-2-27(Shock)  IEC60068-2-6(Vibration) ISW-511/621 (1/2 100Base-FX ports) IndustrialIP30Din Rail

20 www.planet.com.tw 20 / 33 Features IGS-501 / IGS-801 5/8-Port Gigabit Industrial Switch Hardware Feature Comply with IEEE 802.3, IEEE 802.3u 10 /16G switch fabric RJ-45 Port support auto MDI/MDI-X function Wide-range redundant power design Store and forward switch architecture DIN rail and wall mount design Relay alarm output for power input failure Industrial Conformance -10 to 60 Degree C operation temperature 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power IP-30 metal case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 Stability testing with  IEC60068-2-32(Free fall)  IEC60068-2-27(Shock)  IEC60068-2-6(Vibration) IGS-501/801 (5/8 10/100/1000 ports) IndustrialIP30Din Rail

21 www.planet.com.tw 21 / 33 Features IGS-501T / IGS-801T 5/8-Port Gigabit Wide Temperature Industrial Switch Hardware Feature Comply with IEEE 802.3, IEEE 802.3u 10 /16G switch fabric RJ-45 Port support auto MDI/MDI-X function Wide-range redundant power design Store and forward switch architecture DIN rail and wall mount design Relay alarm output for power input failure Industrial Conformance -40 to 75 Degree C operation temperature 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power IP-30 metal case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 Stability testing with  IEC60068-2-32(Free fall)  IEC60068-2-27(Shock)  IEC60068-2-6(Vibration) IGS-501T / 801T (5/8 10/100/1000 ports) IndustrialIP30Din Rail

22 www.planet.com.tw Features Industrial Media Converter

23 www.planet.com.tw 23 / 33 Features IFT-802/802S30 TP to Fiber Industrial Media Converter Hardware Feature Comply with IEEE 802.3, IEEE 802.3u CSMA/CD Protocol RJ-45 Port support auto MDI/MDI-X function SC single-mode/multi-mode fiber optical interface Up to 30km connection distance (single-mode) Wide-range redundant power design Store and forward switch architecture DIN rail and 3-way wall mount design Industrial Conformance DIP switch Port enable/disable alarm, LLF configuration, FX full/half-mode configuration 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power 0 to 60 Degree C operation temperature IP-30 Aluminum case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 UL, cUL, CE/EN60950 safety Stability testing with IEC60068-2-32(Free fall), IEC60068-2- 27(Shock) and IEC60068-2-6(Vibration) IFT-802 (1 Fast Ethernet port, 1 100Base-FX mm,sc) IndustrialIP30Din Rail

24 www.planet.com.tw 24 / 33 Features IGT-90x 10/100/1000Base-T to 1000SX/LX Industrial Managed Media Converter A. Hardware Feature Comply with IEEE 802.3, IEEE 802.3u 10 /16G switch fabric RJ-45 Port support auto MDI/MDI-X function SC single-mode/multi-mode fiber optical interface Up to 120km connection distance (single-mode) Wide-range redundant power design Store and forward switch architecture DIN rail and wall mount design Relay alarm output for power input failure B. Industrial Conformance -10 to 60 Degree C operation temperature 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power IP-30 metal case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100- 4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 Stability testing with  IEC60068-2-32(Free fall)  IEC60068-2-27(Shock)  IEC60068-2-6(Vibration) IGT-90x ( 1 10/100/1000 TP 1 1000SX/LX Fiber ) IndustrialSNMPVLAN

25 www.planet.com.tw 25 / 33 Features IGT-90x Managed Industrial Media Converter C. Switching Feature 802.1q Tagged / Q-in-Q VLAN IEEE 802.1p class of service, 4 priority queues IP TOS/DSCP priority IEEE 802.3ah OAM / TS-1000 OAM 802.1Q / QinQ VLAN QoS / Bandwidth Control 9K Jumbo frame D. System Web management SNMP v1, v2c monitoring and Trap alarm ModelIGT-902IGT-902SIGT-905A Fiber ConnectorSC 1000Base SFP ModeMultimodeSingle Mode Multimode, Single Mode and WDM Max. Fiber Distance550m10kmDepends on SFP module

26 www.planet.com.tw 26 / 33 Features ICS-210x RS-232/422/485 over Fast Ethernet Industrial Media Converter / Device Server Hardware Feature Comply with IEEE 802.3, IEEE 802.3u 1 RS-232 DB9 port 1 RS-422/485 terminal block 1 10/100Base-TX or 100Base-FX RJ-45 Port support auto MDI/MDI-X function Wide-range redundant power design Store and forward switch architecture DIN rail and wall mount design Relay alarm output for power input failure Industrial Conformance -10 to 60 Degree C operation temperature 12~48V DC, redundant power with polarity reverse protect function and connective removable terminal block for master and slave power IP-30 metal case EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE EN6100-4-5 and CE EN6100-4-6 Stability testing with  IEC60068-2-32(Free fall)  IEC60068-2-27(Shock)  IEC60068-2-6(Vibration) ICS-210x (1 10/100 TP or 100FX 1 DB9 RS-232 1 RS-422/485 4-pin Terminal block ) IndustrialWEBDin Rail

27 www.planet.com.tw Comparison

28 www.planet.com.tw 28 / 33 Comparison ISW-1022M Manufacturer PLANETHIRSCHMANNRuggedcomMicrosensMOXA ModelISW-1022MRS30-0802T1T1SDAUHHRS900GMS650869MEDS-510A-3GT Product Image Hardware 10/100Base-TX88877 10/100/100Base-T22- - 3 1000 Mini-GBIC SFP2 (Shared)-23- 100Base-FXcompatible-- - EnclosureIP-30 AluminiumIP-20IP-40 - IP-30 metal Operation Temperature -10~60 Degree C 0~60 Degree C-40~85 Degree C-20~60 Degree C0~60 Degree C Power Inputs12~48VDC 9~36VDC18~36VDC12~45VDC Redundant12~48VDC24V AC 36~59VDC18~36VDC12~45VDC Connector6-Pin Terminal Block 5-Pin Terminal Block2 x 2-Pin Terminal Block6-Pin Terminal Block Data Redundancy Data Redundant - Ring - Coupling Ring - Dual homing - Hiper Ring - Coupling Ring - Dual homing eRSTPRing - Turbo Ring - Coupling Ring - Dual homing Recovery Time< 20ms< 300ms< 5ms-< 20ms Spanning Tree Protocol802.1d / 1W802.1d / 1W /1s -802.1d / 1W

29 www.planet.com.tw 29 / 33 Comparison ISW-500 ManufacturerPLANETHIRSCHMANNMOXATransitionMicrosensB & B EuropeRuggedcomUnicom Model ISW-500 RS2-5TXEDS-305 SISTF1011- 140-LR MS650462EIR-306RMC-40FEP-93004T Type5-Port TP 4 TP + 1 Fiber4 TP + 2 Fiber6-Port TP4-Port TP Power SupplyTerminal Block Screw terminalTerminal Block Power Requirement 24V DC 130mA max. 24V DC 250mA 24V DC 200mA 18-36V DC 500Ma max 24V DC 1.5A 24V DC, 48V DC 24V DC RedundancyRedundant24V redundant Redundant DiagnosticsLEDsLEDs, Alarm LEDs Operation Temp 0~60 o C -20~60 o C-34~74 o C-40~85 o C0~60 o C Storage Temp-40~85 o C-25~70 o C-40~85 o C-40~75 o C-20~80 o C-45~93 o C--40~85 o C Dimension (mm)54 x 135 x 10540 x 145 x 8053 x 135 x 10548 x 105 x 13538 x 108 x 11650 x 135 x 12590 x 52 x 90- MountingDIN RailDIN Rail 35 mmDIN Rail Wall mount DIN Rail 35 mm DIN Rail, 35mm DIN Rail, Panel Mount Protection Class IP 30IP 20IP 30 Metal Case IP 40 SteelMetal Case StabilityIEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall -IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall - EMCFCC Part 15, CE

30 www.planet.com.tw 30 / 33 Comparison ISW-800 ManufacturerPLANETHIRSCHMANNMOXATransitionB & B Europe ModelISW-800RS2-TXEDS-308SISTF1011-170-LREIR-308 Type 8-Port TP 7 TP + 1 Fiber8-Port TP Power Supply Terminal Block Power Requirement 24V DC 290mA max. 24V DC 250mA 24V DC 200mA 24V DC 1.5A Redundancy Redundant 24V redundant Redundant Diagnostics LEDs LEDs, Alarm Operation Temp 0~60 o C -34~74 o C Storage Temp -40~85 o C -25~70 o C-40~85 o C-40~75 o C-45~93 o C Dimension (mm) 54 x 135 x 105 47 x 135 x 11153 x 135 x 10548 x 105 x 13550 x 135 x 125 Mounting DIN Rail DIN Rail 35 mmDIN Rail Wall mount DIN Rail 35 mmDIN Rail, 35mm Protection Class IP 30 IP 20IP 30 Metal Case Stability IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall EMC FCC Part 15, CE

31 www.planet.com.tw 31 / 33 Comparison IFT-802 ManufacturerPLANETMOXATransitionMicrosensB & B EuropeRuggedcom ModelIFT-802IMC-101MSCSISTF1011-140-LRMS650420EMD-100FSTRMC Type 100 TP to SC 100 TP to ST/SC Power Supply Terminal Block Screw terminalTerminal Block Power Requirement 24V DC 250mA 24V DC 200mA 18-36V DC 500Ma max 10-36V DC24V DC, 48V DC Redundancy Redundant 24V redundantRedundant Diagnostics LEDs LEDs, Alarm LEDsLEDs, Alarm Operation Temp 0~60 o C -20~60 o C-0~60 o C-40~85 o C Storage Temp -40~85 o C -40~75 o C-20~80 o C-40~85 o C- Dimension (mm) 54 x 135 x 105 53 x 135 x 10548 x 105 x 13538 x 108 x 11640 x 79 x 8590 x 52 x 90 Mounting DIN Rail Wall mount DIN Rail 35 mmDIN Rail, 35mm DIN Rail, Panel Mount Protection Class IP 30 Metal Case IP 40 Steel Stability IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall -IEC Shock IEC Vibration IEC Free Fall IEC Shock IEC Vibration IEC Free Fall EMC FCC Part 15, CE

32 www.planet.com.tw 32 / 33 Roadmap Ethernet to RS-232/485 TP/Fiber ICS-210x 5/8-Port 10/100/1000 Industrial Switch IGS-501 / IGS-801 2009/Q2 2009/Q3 10/100/1000 to 1000Base-SX/LX Industrial Media Converter IGT-90x L2 Dept. Mgt. Sec. 24 10/100 + 2G TP/SFP combo Managed Industrial Switch SGSW-2840I 8 10/100 + 2G TP/SFP combo Managed Industrial Switch Ring / Power Redundancy ISW-1022M 5/8-Port 10/100/1000 Wide Temperature Industrial Switch IGS-501T / IGS-801T 4-Port 10/100 + 1 FX Industrial Switch -40 ~75 degree C ISW-511T / ISW-511S15 4-Port 10/100 + 2 FX Industrial Switch -40 ~75 degree C ISW-621T / ISW-621S15 5-Port 10/100 with 4 PoE Industrial Switch ISW-504P / ISW-514P 5-Port 10/100 with 4 PoE Manageable Industrial Switch ISW-504PS / ISW-514PS Industrial Managed Switch 8+2G TP/SFP Wide Temperature ISW-1022MT

33 www.planet.com.tw

34 Appendix Features Update

35 www.planet.com.tw 35 / 33 DIN-Rail / Wall Mount Installation DIN-Rail Installation Wall Mount Installation

36 www.planet.com.tw 36 / 33 Power Redundant PWR1 & PWR2 12~48V DC redundant power input 1A@24V Relay alarm for power down and port down (Managed model) Power polarity reverse protect Connective removable terminal block for master and slave power Provide additional DC jack for AC/DC power adapter

37 www.planet.com.tw 37 / 33 Data Redundant Redundant Ring 2 Ports for redundant ring Provide redundant backup feature Recovery time below :  ISW-1022M: 20ms  ISW-800M/802M: 300ms Start by Web INTERFACE MANAGEMENT The ring port can be defined by Web Master Switch in the Network Network’s Backup Segment Redundant Ring

38 www.planet.com.tw 38 / 33 Alarm relay & Ring setup 1 - 8 Port Alarm To determine faults at the copper or fiber ports on: Enables the corresponding port alarm The internal relay forms an open circuit and the FAULT LED lights up if the link for that port fails 1A@24V Relay alarm R.M. (Ring Master) Enables the device to be the Ring Master in a Redundant Ring topology Enables the Redundant Ring break alarm If a link in the Redundant Ring breaks, the internal relay would form an open circuit and the FAULT LED lights up 1 2 3 4 5 6 7 8 R.M. Port Alarm Ring Master