Translator Machine Interface Contact : David vd Merwe 082 6836 472 The System interface old to new. Some controllers do not have.

Similar presentations


Presentation on theme: "Translator Machine Interface Contact : David vd Merwe 082 6836 472 The System interface old to new. Some controllers do not have."— Presentation transcript:

1 Translator Machine Interface Contact : David vd Merwe 082 6836 472 http://remotedata.co.za The System interface old to new. Some controllers do not have the ability to communicate to the outside word via IoT, www, printers scanners, database, Plasma screens, 3G etc. The latest trend is Internet of Things where you can manage your systems and Data remotely. With this controller you can interface a wide range of devices to bring different systems and devices to a single intergraded system.

2 System Description The controllers has got Analog, digital inputs, outputs and communication ports to talk to the outside world. 1. The system can be used as a PLC “Programmable Logic Controller” via IO. 2. Database for logging and information. 3. Message via Email, Whatsapp, Telegram etc. 4. Web base interface on Tablets PC and Smart phones 5. Scanning and batch counting 6. Printing and Reporting 7. NAS Server 8. Multimedia and Home 9. Radio Telemetry up to 15km line of side 10. 3G and WIFI 11. GPS Contact : David vd Merwe 082 6836 472 http://remotedata.co.za

3 MIT Controller Master Controller RADIO Unit 433 866 MHz transceiver 20dBm output power -136dBm sensitivity Multiple channels RS485 – RS233 - TTL interface Supply voltage: 7.5 – 24VV Line-of-sight distance:100m~2KM Processor : Armv7 900MHZ Memory : 1024K Video out : HDMI, AVI 5mm Stereo : Output for Sound USB 2 : 4 100M LAN : 1 Storage : Micro SD / SD / External HDD Internal Fan : 1 Power supply : 240VAC – 12V 2Amp 5V 1.5Amp Dimensions : W160 x H55 x L125mm Operating System Linux Web Interface PLC Programming. Analog : 8 x 12bit 0-5V 0-10V Outputs : 4 x open collector 800mA : 4 x open collector 2Amp Inputs : 3 x Opto isolated Communication : 2 x RS485 / 1x RS422 : 1 x RS232 Add-on : GPS, Radio Link, RFID etc. Optional : WIFI Hotspot, WIFI, 3G Modem Wireless Keyboard and Mouse Contact : David vd Merwe 082 6836 472 http://remotedata.co.za

4 Software and Add-ons Other Programs and Control. 1.OMAMS Plant Interface 2.Weigh Bridge with dbase 3.Irrigation and Home Control 4.Safe and Key lock 5.Presentation and Display board 6.Media Player 7.RFID and Sector Control 8.Webcam 9.Over 200 PLC Commands to control Server 10.Timeline Control 11.Samba Server 12.Vehicle Entertainment Server. 13.Alarm System Caravan etc. 14. PET Production Efficiency Toolkit http://remotedata.co.za Contact : David vd Merwe 082 6836 472 http://remotedata.co.za

5 Production Efficiency Toolkit HDMI Information Screen PET Controller UPS and Power Supply Transceiver 433/866mHZ / 2.4G RS485 Modbus Interface and Reporting Web based Software LAN / WIFI

6 PET Description Contact : David vd Merwe 082 6836 472 http://remotedata.co.za The system is design aground the concept of a Actual versus plan production and down time. Predefined buttons are add to call for maintenance, Electrical etc. Cycle time and product produced are count. The actual versus planned are setup for a shift. Normal Lunch, Tea breaks and startup breaks are separate log for a detail report. When a call button is press the system will associate the correct message group and Error code. The system log the call and a Whatsapp, Telegram or email will be send to the group. The overhead display board will display the error and relevant information. On the controller a Call Indicator will display. When the maintenance attend the problem a key switch must be turned. The time arrived will be log. After the repair or call the maintenance clear the call with the key switch position 2. Detail reporting on every Error etc. A progress or actual versus plan Tower lights can be added to increase performance.

7 OMAMS Contact : David vd Merwe 082 6836 472 http://remotedata.co.za Open Mine Asset Management System Data are capture on 3G controllers connected to PLC or weighing controllers. Data are send to a remote data server The MIT are connected via 3G to the server. Data are display on a Plasma screen where Daily reporting and information are displayed The Customer can access the system via Smart phone to set predefined settings to alert or send messages to his phone or group of phones or systems. Live site http://remotedata.co.za/mine Logon as demo and password demohttp://remotedata.co.za/mine

8 Safe and Key Management Contact : David vd Merwe 082 6836 472 http://remotedata.co.za Secure Web Users. Webcam Pictures every action Basic System 1. Secure User Time base Access 2. Maximum Keys / user / taken 3. Authority Selection and Time to use 4. Web Cam Log of every Action 5. Every Key hardware Lock with Key pin. 6. LED key position indicator. 7. History for all key movements with Webcam pictures 8. Alarms. 9. Restricted authority key movement 10.Easy import Asset information 11.Full reporting of safe entry, key use Demo KM etc.. 12.Define User logon privileges 13.Interface older Safes with IASMS System. 14.Network Safes to a central database. 15.7” Touch Screen interface with detail data on screen. Full System an Asset Status Wi-Fi Tablet and Smart phones Access to System 7” Touch Screen Interface Secure key with lock pin

9 Typical Web Interface Contact : David vd Merwe 082 6836 472 http://remotedata.co.za

10 AMP (Asset Management and Position) Controller Contact : David vd Merwe 082 6836 472 http://remotedata.co.za Processor : Mega128 Memory : 128K Coms : 1x RS485 Analog : 2x 0-5V / 0-10V 10bit Inputs : 3x Opto Isolated Internet : 1x 3G Modem Vodacom Card RTC Power supply 7.5-28V DC 0.75Amp Dimensions: W95 x H50 x L110mm Add-on cards Analog, Outputs, Inputs, RS232- RS485- RS422, GPS, Radio Link, RFID etc. Access. Webpage / Cell phone / Tablet Applications 1.Wash Plants 2.Tracking of vehicles 3.Level Control etc.. 4.Current Protocols Modus: - Rhino, Route, Ningi, BW100. Data String:- PA, Inteliway, (Predefined String) 5. Customize Protocols Coms CardGPS Add-on Description The AMP unit connect via internet to a server. Selected data fields are updated every 60 seconds to the server. A Real-time record of the selected fields are showing on a client Webpage interface. A Report interface allows the client to Print detail or graph reports. Data can also exported to a excel sheet. Full data is backup up to 6 months. Older data can be requested. Setup Field Description and Calculations Reporting Web Interface Demo Web Site http://remotedata.co.zahttp://remotedata.co.za – Main Website http://remotedata.co.za/minehttp://remotedata.co.za/mine - OMAMS Website Login and passw “demo” This is a real-time wash plant with only names hidden. Contact : David vd Merwe 082 6836 472

11 Remote Switch and Control Contact : David vd Merwe 082 6836 472 http://remotedata.co.za Features:  60 Amp latching relay.  Shunt based IEC Class 0.5 compliant single phase measurement unit.  Battery backed real time clock.  Settable on/off times.  Settable load limiting.  Din rail mountable. Typical applications:  Remote controllable geyser switch with time control and KWH monitor.  Security lights.  Fridge and freezer time control and KWH monitor.  Split single phase meter.  Street light and high mast intelligent management unit.  Office lights time control and KWH monitor.  Irrigation.  Remote controllable pool timer and KWH monitor.  General power switch. Connect this device via 3G / Radio link to MIT server and control and display Status and consumption live.