PROTECT 3.M 15 – 120kVA. PROTECT 3.M the new generation of uninterruptible power supplies (UPS) with 3-phase Mains input and 3-phase Mains output.

Similar presentations


Presentation on theme: "PROTECT 3.M 15 – 120kVA. PROTECT 3.M the new generation of uninterruptible power supplies (UPS) with 3-phase Mains input and 3-phase Mains output."— Presentation transcript:

1 PROTECT 3.M 15 – 120kVA

2 PROTECT 3.M the new generation of uninterruptible power supplies (UPS) with 3-phase Mains input and 3-phase Mains output

3 PROTECT 3.M General data PROTECT 3.M will be offered in two cubicle variances. Variance 1: Cubicle dimensions: (W x H x D) 600mm x 1600mm x 1000mm Maximum 6 modules each 15kVA = 90kVA per cubicle Variance 2: Cubicle dimensions: (W x H x D) 600mm x 2000mm x 1000mm Maximum 8 modules each 15kVA = 120kVA per cubicle 15kVA per Modul (hot-swappable) Degree of redundancy selectable via Display Each Modul is independent, Controllcard/Display are just for Communication and Indication. Integrated Distribution with up to 36 breakers as an option LCD Display Communication via RS232, RS485, SNMP & AS400

4 PROTECT 3.M General data 1.6 m cubicle MB at the bottom 2.0 m cubicle MB at the top

5 PROTECT 3.M High MTBF ability Each UPS module in the Protect 3.M is the full function UPS. There is no additional controlling module to the parallel application and load sharing. Regarding to the serious calculation on the system MTBF, if you have two more UPS modules for parallel redundancy, the system ability is above 99.999% and the MTBF will be close to 15 Million Hours. MTTR Once the system has one more UPS module for parallel redundancy, the system will still keep working if one of the UPS modules fails. If the failed modules exceed the parallel redundancy modules, the module replacement procedure only need 5 minutes for system recover.

6 PROTECT 3.M Battery Battery +/- 240Volt DC (20 bloc for each string) Integrated batteriecharger in each Module (2700W / 4.5A) Battery Management in two steps Step 1) up to 90% battery capacity  constant current Step 2) above 90% capacity  constant voltage

7 PROTECT 3.M Technical data part I Classification VFI SS 111 acc. to IEC 62040-3Protect 3.M 1.6m rackProtect 3.M 2.0m rack Type power90 kVA120kVA 72 kW96 kW max. modules per rack68 UPS-input Input voltage400 / 230Vac (3/N/PE~) Input voltage range without battery mode277 - 520Vac(3ph~) Frequency50 Hz / 60Hz Current consumption (max.) 120A with 6 modules 160A with 8 modules Power factor> 0.99 at 100% Load THD(i)<=5% UPS-output Rated output voltage400V ± 2% Frequency in battery mode50 Hz ± 0.5% Output current 22 A / per module 132A with 6 modules 22 A / per module 176A with 8 modules Transfer time at mains outage0 ms ( zero transfer ) Voltage waveformSinusoidal Overload response (online mode)130% for 10min / 150% for 1min Crest factor3

8 PROTECT 3.M Technical data part II Battery Nominal voltage 240VDC (40pcs for each set in series connection. One battery neutral wire from the central) Autonomy timeFree to choose runtime extension with scalable external battery. Available configurations with 24,38 or 65 Ah) Overload / deep discharge protectionYes Communication InterfacesRS232 / RS485 for status and measurement values, Communication slot ( for pot.-free contacts or SNMP adapter) Shutdown software (on CD)Included for all typical operating systems (e.g. MS- Windows,Novell Netware,Mac OS,Linux,Unix derivates, etc.) Failure indicators (acoustic/optical)LCD with digital information of input and output parameters (voltage,frequency,power etc.) battery parameter incl. failure diagnosis by password protect level, LED for status and main failures.

9 PROTECT 3.M Technical data part III General data Efficiency total> 90% Audible noise (1m distance)<62 dB Operating temperature range0º - 40 ºC Humidity20% - 90% Installation heightup to 1000m, at nominal load Equipment colourRAL 7035 Size approx.W x H x D (mm)600 x 1600 x 1000 600 x 2000 x 1000 Weight appr. (kg) 250kg rack + 35kg per module 300kg rack + 35kg per module CertificationCE

10 PROTECT 3.M · Applications Single - and multi-user systems ( Workstations, FileServer, Application Server,... ) Network protection (client / server architecture) e.g. intranet / internet application EDP - equipment (CAD - systems,...) Communication equipment (IT - sector) Component protection of telecommunication Cash systems (trade) Other user-critical applicationen (process systems (stored-program contoller,... ))

11 PROTECT 3.M · conceptual highlights Modularity with UPS plug-in modules in VFI (double-conversion) technology n + x technology free choice of redundancy level scalable design for flexible power- / autonomy time requirements central simplified management more efficient service independent UPS - modules (without any central control logic)

12 PROTECT 1.M · UPS classes Publication by ZVEI: UPS Guide........... by additional lightning arrestors Voltage Phenomenon Time e. g. IEC UPS solution 62040-3 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Outage - blackouts Sags / brownouts Dynamic overvoltage Undervoltage Overvoltage Lightning Transients (Surge) Frequency variations Voltage distortion (Burst) Voltage harmonics > 10 ms continuous sporadic < 4 ms sporadic periodic continuous VFD Voltage + Frequency Dependent VI Voltage Independent VFI Voltage + Frequency Independent Classification 3 Offline Classification 2 LineInteractive Classification 1 (true) Online real Double- Conversion

13 Protect 3.M System architecture Integrated Distribution with up to 36 breakers as an option Communication module incl. communication port LCD-Display UPS-modules each 15kVA

14 PROTECT 3.M · UPS module design Inverter Battery system Rectifier Load Mains Electronic static bypass ~ ~ Battery charger ~ PFC Filter Mains filter DSP / CanBus control logic unit RS232 SNMP DC/DC Booster High power reserves as a result of a max. 24 kVA total output High safety reserves as a result of n+x technology Independent UPS modules (no central control) slide-in types; suitable for rackmount Diagram of an UPS PROTECT module :

15 PROTECT 3.M · n + x technology · redundancy level n + x technology advantage Quantity of UPS modules12345678 Loadmodulmodules 15 kVA no redundancyn + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) n + 5 (75 kVA) n + 6 (90 kVA) n + 7 (105 kVA) 30 kVA no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) n + 5 (75 kVA) n + 6 (90 kVA) 45 kVA no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) n + 5 (75 kVA) 60 kVA- - - no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) 75 kVA - - - no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) 90 kVA - - - no redundancy n + 1 (15 kVA) n + 2 (30 kVA) 105 kVA - - - no redundancy n + 1 (15 kVA) 120 kVA - - - no redundancy Higher reliability Easy to increase overall capacity Modules hot - swapable (without any interruption)

16 Protect 3.M Usage >> Delivery Cubicle packing Module packing

17 Protect 3.M - Mains connection MainsBatteryLoad

18 PROTECT 3.M – LCD display Appear „green light“ Appear „yellow light“ Appear „red light“ and warning alarm

19 PROTECT 3.M Communication interface “Dual monitoring“ interface from left to the right: - RS485 - RS232 - RS485 - Expansible AS/400 card with potential-free contacts SNMP / SNMP PRO card (with connector for additional temperature measurements)

20 PROTECT 3.M SNMP-Adapter SNMP Slot-Adapter for UPS Features: Agent for RFC1628 MIB UPS standard MIB Embedded Web-Server  Monitoring via Web  Configuration via Web Embedded Event Manager  Start of different Jobs  Net Broadcast  E-Mail Monitoring of environmental conditions  Temperature, Humidity, GenSet, Fire, Air condition, Smoke shutter... Support Software products  Network Management Software „NMS“  NMS special for Power Supply Systems  Shutdown Software “CompuWatch”  Direct multi-server shutdown of different OS with communication modules SNMP Adapter Pro: 6000001271 SNMP Adapter: 6000004036

21 PROTECT 3.M AS/400 slotcard Pin 1:UPS Fault Battery below cutoff voltage Pin 2:Summary Alarm: UPS failure, Utility power failure, Battery low Pin 3 and 4:Short from Pin 3 to 4 generates an UPS shutdown, e.g. by installing an external switch for EPO. Pin 5:Common ground for relays (pins 1, 2, 6, 7, 8 und 9) Pin 6:Bypass active; mains operation Pin 7:Battery low Battery voltage is below the predetermined level Pin 8:UPS on; normal operation (relay closed during normal operation) Pin 9:Utility Failure; battery operation Attention ! Contact load rating: AC / DC  24 V / 0,5 A Pin- assignment Description 1UPS Failure 2Summary alarm (signal of pins 1, 7and 9) 3Emergency shutdown, e.g. connection of an external switch for EPO (closer) 4 5Common ground for pins 1, 2, 6, 7, 8 und 9 6Bypass active 7Battery low 8UPS on 9Utility Failure

22 UPS system: PROTECT 3.M Graphical front-end of CompuWatch Normal operation

23 PROTECT 3.M