Breakthrough Precision in Field Measurements Robin Wang Application Consultant.

Similar presentations


Presentation on theme: "Breakthrough Precision in Field Measurements Robin Wang Application Consultant."— Presentation transcript:

1 Breakthrough Precision in Field Measurements Robin Wang Application Consultant

2 The only one-hand-operation Microwave Analyzer Cable and Antenna Analyzer 30kHz to 26.5GHz Cable and Antenna Analyzer 30kHz to 26.5GHz Full 2 port Vector Network Analyzer with time domain analysis, 30kHz to 26.5GHz Spectrum Analyzer, with full band tracking generator 5kHz to 26.5GHz Spectrum Analyzer, with full band tracking generator 5kHz to 26.5GHz Power Meter 5kHz to 26.5GHz Power Meter 5kHz to 26.5GHz Independent Signal Generator 30kHz to 26.5GHz Independent Signal Generator 30kHz to 26.5GHz Vector Voltmeter 2 port, 30kHz to 26.5GHz Vector Voltmeter 2 port, 30kHz to 26.5GHz Interference Analyzer Variable DC Source Light weight: 6.6 lbs Long battery life: 3.5 hrs Bright display: 6.5 inch TFT MIL PRF 28800 F Class 2 CISPR 11 Class B Built in GPS Frequency Counter

3 9 GHz 14 GHz 18 GHz 26.5 GHz 4 GHz 6 GHz RF/uW Handheld Portfolio Agilent Confidential CAT only VNA Combo ANALYZER SAHSA 20 GHz 13.4 GHz 7 GHz 3 GHz N9330B N9912A-104 N9912A-106 N9913A N9918A N9917A N9916A N9915A N9914A N9938AN9937AN9936AN9935A N9923A-106 N9923A-104 N9925A N9927A N9926A N9928A N9340B N9342C N9344C N9343C Industry’s Most Rugged Accurate Cost Effective Carry Precision with You!

4 Targeted Markets Comm Test on Ship and aircraft Frequency Management MW backhaul Radar /Comm Test SAT Ground Station Maint. EW system support Education

5 Radar, Aircraft, Battleship communication system maintenance Key Applications - UHF/VHF, MW, Radar and Satellite Antenna test - Cable Sweep (very long cable) - Duplexer, filter verification - Pulse measurement - Transmitter power measurement - Receiver sensitivity - VOR/ILS system test -Signal monitor over the air Why FieldFox: - QuickCal / Unknown Thru - Built in power meter - Independent Source - 2 port VVM to verify phase array antenna - Spectrum analysis with recording - VNA with flattened output power - Ruggedized package, battery powered (more examples in backup slides)

6 New accessories to support microwave analyzers Cal kits: 6GHz, 9GHz, 18GHz and 26.5GHz Yagi Antenna Cell and PCS Waveguide cal kits Microwave Test Cables Adapters Trigger, IF, DC out cable

7 FieldFox Family Configurations and Comparisons N9913/14/15/16/17/18A All in one N9925/26/27/28A VNA N9935/36/37/38A SA Base unitCable and antenna Analyzer VNA T/RSpectrum Frequency breaks4/6.5/9/14/18/26.5 GHz9/14/18/26.5 GHz Spectrum analyzerYesNoYes Cable and antenna Analyzer Yes No 2 port VNAYes No Tracking GenYesNoYes Independent CW Source YesNoYes Built in power meterYes

8 8 uW FieldFox (w/DUT) Laptop LAN-based Display Controller 67 GHz PSG Signal Generator Multi -Instrument Display Viewing Monitor DC Power Supply N1914A Power Meter & 26.5 GHz Sensor 50 GHz PXA Signal Analyzer 67 GHz PNA-X Vector Network Analyzer Agilent Confidential December 2012 FieldFox to High Performance Benchtop Comparison

9 9 Microwave FieldFox Compared to PNA-X FieldFox trace is blue PNA-X trace is brown +23 dBm S21 Receiver Accuracy is identical S12 Isolation traces are identical S11 Reflection is identical S22 Reflection is identical ISM 2012 Bengaluru December 2012

10 10 Microwave FieldFox Compared to PNA-X Delta MarkerS11S21 Mkr 2 Passband0.02 dB0.02 dB Mkr 1 Left Filter Skirt0.02 dB0.52 dB @ 78 dB down Mkr 3 Right Filter Skirt 0.00 dB0.11 dB @ 65 dB down DUT is 10.24 GHz Passband Filter 10 ISM 2012 Bengaluru December 2012 FieldFox trace is Green & Magenta PNA-X trace is Brown & Blue

11 11 FieldFox SA has Superior Phase Noise Example #4: New LO MMIC yields phase noise Improvement 11 Phase noise at 1 GHz: FieldFox vs. ESA uW FieldFox detects signals previously found only by bench-top instruments. ~15 dB better than ESA (-110 dBc/Hz @ 10-kHz offset) uW FieldFox vs. ESA ISM 2012 Bengaluru December 2012

12 12 Actual measured values InstAlign provides: Industry-leading amplitude accuracy of ± 0.6 dB at power- on, no warm up required Valid over the full frequency range and operating temperature of -10 to +55 deg C Microwave FieldFox Compared to Power Meter ISM 2012 Bengaluru December 2012

13 Rack Mounted FieldFox for Agilent SMT Pkg Test Benefits: Much lower cost solution Performance and accuracy of FieldFox met the requirements Measurement time is << than part handling time 13 Agilent Confidential December 2012 A single FieldFox RF Analyzer replaced a legacy VNA, spectrum analyzer and power meter Application: Low volume, on-wafer manufacturing test applications Measuring ICs Measuring S21 gain, power, harmonics

14 14 Rugged Enough to Meet MIL-PRF-28800F Class 2 14 Field-proof Completely sealed instrument enclosure provides measurement stability in harsh environments 3-year warranty ensures field confidence (standard on all FieldFox analyzers) Low Emissions, meets CISPR Pub 11, class B Water-resistant chassis, keypad, and case withstand wide temperature ranges, and salty, humid environments Case withstands shock and vibrations Wide operating temperature -10 to +55 °C (14 to 131 °F) Wide storage temperature -51 to +71 °C (-60 to 160 °F) MIL-spec durability Meets MIL-PRF-28800F Class 2 requirements Type tested and meets MIL-STD-810G, Method 511.5 Procedure I requirements for operation in explosive environments ISM 2012 Bengaluru December 2012

15 15 Summary: Results of MMIC Integration FieldFox has the same measurement science as high end benchtops resulting in direct measurement correlation FieldFox rugged design meets MIL-PRF-28800F Class 2 and has been type tested to MIL-STD-810G Explosive Atmosphere test. Meets CISPR 11 Class B. Agilent Confidential December 2012 Agilent MMICs enable FieldFox analyzers to establish a new level of performance to 26.5 GHz in a 14 watt, no fans or vents, easy to use instrument Integration = higher reliability, enables standard 3 Year warranty FieldFox combination analyzers can be configured with up to ten instruments in one which is extremely useful for both field and R&D lab measurements

16 16 Precision. Readiness. FieldFox 16 Count on the durability of FieldFox - designed to withstand the toughest working conditions. Carry precision with you: our microwave models deliver Agilent-quality measurements wherever you need to go. Boost your readiness: with our RF units, every operating mode is flexible to meet the needs of novices and experts alike. “The technology Agilent has developed is simply superior.” - Major aerospace/defense prime contractor Agilent Confidential December 2012

17 17 Additional Information Application note series Interference analysis, cable and antenna analysis, calibration and alignment, time domain, power measurements, and site survey Product literature Family brochure, technical overviews, data sheet, configuration guide, tri-fold photo card Product introduction and demo videos www.agilent.com/find/FieldFox Interference analysis, cable and antenna analysis, precise field calibration and more Webcasts 17 Agilent Confidential December 2012