1 Wiremold ® OFR Series Overfloor Raceway System

2 Need existed for divided pancake  Primarily in fitness centers, classrooms. Open space areas where coming through floor or ceiling is not an option.  On grade  Trenching is too expensive  May not have access to floor below (different tenant)  Historical building Introduction - Background

3 Conference rooms with multiple service requirements  Power, Communications and AV New classroom configurations  Pod style  Feeding Smart boards Auditoriums for podiums Increase in Communication and AV requirements Introduction - Background

4 OFRB-88 ft base (4 per carton) OFRBC-88 ft base and cover (1 per carton) OFRC-88 ft cover (4 per carton) OFR10AEntrance End Fitting OFR48-22-Gang Device Box OFR48-44-Gang Device Box OFRWCWire Clip OFR89-2400Transition from 2400 Raceway to OFR OFR89-4000Transition from 4000 Raceway to OFR OFR89-DS4000Transition from DS4000 Raceway to OFR OFR89-VISTransition from Vista Point5 to OFR Product Listing

5 OFR11Flat Elbow OFR1Coupling OFR09Grounding Clip OFR47-BBlank Device Plate OFR47-DDuplex Plate OFR47-RDecorator Plate OFR47-UExtron MAAP Plate OFR47-VExtron AAP Plate OFR47-2ACommunication Device Plate OFR47-U2AComb. AV/Comm Plate OFR48-4GX4-Gang Device Box Crossover Kit Product Listing

6 Low profile  Unobtrusive, ADA compliant design. Installs in open space areas  Provides power, communications and AV wiring to areas where in-floor and ceiling distribution is not an option. Multi-channel base  Provides space for multiple combinations of power, communications and AV in one raceway. System Features & Benefits

7 Open system device plates for data and AV  System can accommodate a wide variety of devices and manufacturers. Attaches directly to floor covering (works with carpet, tile, wood, etc)  No need to alter existing floor covering. Meets ADA Accessibility Guidelines  Raceway assembly is designed to meet the ADA Accessibility Guidelines as it pertains to ADA Standard 4.5 which addresses changes in floor and ground surface levels.

8 Black powder coat finish  Durable textured finish, blends with most decors. Multiple transition options  Overfloor Raceway can be fed from the wall, DS4000, 4000 and 2400 Series Raceway as well as Vista Point5 Architectural Column. Tamper resistant  Cover is difficult to remove without proper tools. cETLus listed  Will be UL listed as well. Will be stocked by electrical and communication distributors as well as AV Integrators  Product will be readily available in all channels. System Features & Benefits

9 Raceway Base and Cover Unobtrusive, ADA compliant design. 4 channel base for multiple services. Cover has durable black powder coat finish. Tamper resistant hex screws for cover. Load tested to UL requirements for floor boxes (300 lbs. across 3” diameter). Product Features & Benefits

10 Device Boxes and Plates 4-gang box can accommodate power and communications on both sides with crossover kit. Open system - power, communications and AV can go anywhere. Side mounting of devices provides large cable bend radius inside raceway. Product Features & Benefits

11 Transition Fittings Wall mounted dual channel raceway can transition to any channel of OFR. Entrance End Fitting has ½” and 1 ¼” KO Trade Size. Raceway transitions available for 2400, 4000 and DS4000. Vista Point5 available as well.

12 Applications Fitness Centers  Treadmills, ellipticals, etc.

13 Applications Open Space Areas  Board Rooms and Conference Rooms  New style classroom pods

14 Applications Auditoriums  Lecterns, podiums

15 Technical Information cETLus listed UL listing is pending Meets ADA Accessibility Guidelines  ADA Standard 4.5

16 Vertical Markets Amusement Office Financial Education Retail Construction Hospitality