Presentation is loading. Please wait.

Presentation is loading. Please wait.

IRDAM SA Presents Military products Meteorology for winners! May 2012.

Similar presentations


Presentation on theme: "IRDAM SA Presents Military products Meteorology for winners! May 2012."— Presentation transcript:

1 IRDAM SA Presents Military products Meteorology for winners! May 2012

2 Yverdon-les-Bains is located at the Western end of the Neuchâtel lake. 90 km from Geneva 190 km from Zürich C:\MAWS 6056 presentation (may 2012).ppt page 2/38 IRDAM MILITARY AUTOMATIC WEATHER SENSORS

3 C:\MAWS 6056 presentation (may 2012).ppt page 3/38 Military products Introduction of the Military Automatic Weather Sensors IRDAM 6056 MILITARY AUTOMATIC WEATHER SENSORS

4 The latest Military Automatic Weather Sensors. “MISSION ORIENTED MAWS” MILITARY AUTOMATIC WEATHER SENSORS Military products C:\MAWS 6056 presentation (may 2012).ppt page 4/38 Options for all MAWS models : 6056B 6056BC 6056BCGPS 6056H 6056HC 6056HCGPS Ballistic Ballistic with compass Ballistic with compass & GPS NBC / Artillery / UAV NBC / Artillery / UAV with compass NBC / Artillery / UAV with compass & GPS Main Battle Tanks Small RECCE armored vehicles NBC RECCE vehicles Ground to ground or air defense Product Possible applications Main characteristics TEMPEX Main battle tank ammunition storage NBC vehicles Additional digital temperature sensor KITNBC6056 B or H Main battle tank ammunition storage NBC vehicles Decontaminations kit HOUSSE Main battle tank ammunition storage NBC vehicles Storage / transports

5 Military products IRDAM MAWS6056B 125’060 Vitesse du vent - Wind Speed - Windgeschwindigkeit Plage de mesure - Range - Meßbereich m/s Précision - Accuracy - Genauigkeit± (0,5 m/s + 5%) Résolution - Resolution - Auflösung 0,1 m/s Direction du vent - Wind Direction - Windrichtung Azimut - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5.0° Résolution - Resolution - Auflösung 0,1° Température de l’air - Air Temperature - Lufttemperatur Plage de mesure - Range - Meßbereich - 40°C - +70°C Précision - Accuracy - Genauigkeit ± 1°C Résolution - Resolution - Auflösung 0,1°C Pression atmoshphérique absolue - Absolute Atmospheric Pressure - Absoluter Atmosphärischer Druck Plage de mesure - Range - Meßbereich hPa (mbar) Précision - Accuracy - Genauigkeit ± 5 hPa (mbar) Résolution - Resolution - Auflösung 0,1 hPa (mbar) Option pour sonde de mesure externe - Connection for external intrument - Anschluß für externes Meßintrument Plage de mesure - Range - Meßbereich- 50°C °C Précision - Accuracy - Genauigkeit ± 0.3°C (- 40°C °C) ± 1.2°C (+ 60°C °C) Résolution - Resolution - Auflösung 0,1°C Autotest - Autotest - Selbsttest Permanant - Permanent - Kontinuierlich Enclenchement - Start up - Inbetriebnahme < 20 s Protocole de sortie - Output protocol - Ausgangsprotokoll RS - 485, simplex MilCAN bus Cadence d’émission - Transmission cycle - Meßtakt 100 ms Alimentation - Input voltage - Stromversorgung V DC Consommation - Consumption - Leistungsaufnahme < 25 W Température d’utilisation - Operating temperature - Betriebstemperatur - 40°C °C Température de stockage - Storage temperature - Lagerungtemperatur - 55°C °C Dimensions - Size - Abmeßungen Hauteur - Height - Höhe550 mm Diamètre - Diameter - Durchmeßer 85 mm Base - Base - Basis120 mm Poids - Weight - Gewicht 3.5 kg Options - Options - Optionen Capteur de température de soute à munitions - Ammunition storage temperature - Temperatursonde für Munitionskammer TEMPEX Valise de transport - Transportation case - Transportkoffer PELI Couleur - Color - Farbe Disponible dans les couleurs de la normes FED-STD-595B ou RAL selon les besoins spécifiques du client. Available according to FED-STD-595B or RAL colors or according to customer specific needs. Verfügbar in den Standardfarben FED-STD-595B oder RAL oder nach den spezifischen Bedürfnißen des Kunden. MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 8/38

6 Military products IRDAM MAWS6056BC 125’060 Vitesse du vent - Wind Speed - Windgeschwindigkeit Plage de mesure - Range - Meßbereich m/s Précision - Accuracy - Genauigkeit± (0,5 m/s + 5%) Résolution - Resolution - Auflösung 0,1 m/s Direction du vent - Wind Direction - Windrichtung Azimut - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5.0° Résolution - Resolution - Auflösung 0,1° Direction de la station par rapport au Nord - Direction of the station to magnetic North - Stationrichtung bezugnehmend auf geographischen Norden Azimuth - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5° Résolution - Resolution - Auflösung 0.1° Température de l’air - Air Temperature - Lufttemperatur Plage de mesure - Range - Meßbereich - 40°C °C Précision - Accuracy - Genauigkeit ± 1°C Résolution - Resolution - Auflösung 0,1°C Pression atmoshphérique absolue - Absolute Atmospheric Pressure - Absoluter Atmosphärischer Druck Plage de mesure - Range - Meßbereich hPa (mbar) Précision - Accuracy - Genauigkeit ± 5 hPa (mbar) Résolution - Resolution - Auflösung 0,1 hPa (mbar) Option pour sonde de mesure externe - Connection for external intrument - Anschluß für externes Meßintrument Plage de mesure - Range - Meßbereich - 50°C °C Précision - Accuracy - Genauigkeit ± 0.3°C (-40°C - +60°C) ± 1.2°C (+60°C °C) Résolution - Resolution - Auflösung 0,1°C Autotest - Autotest - Selbsttest Permanant - Permanent - Kontinuierlich Enclenchement - Start up - Inbetriebnahme < 20 s Protocole de sortie - Output protocol - Ausgangsprotokoll RS - 485, simplex MilCAN bus Cadence d’émission - Transmission cycle - Meßtakt 100 ms Alimentation - Input voltage - Stromversorgung V DC Consommation - Consumption - Leistungsaufnahme < 25 W Température d’utilisation - Operating temperature - Betriebstemperatur - 40°C °C Température de stockage - Storage temperature - Lagerungtemperatur - 55°C °C Dimensions - Size - Abmeßungen Hauteur - Height - Höhe550 mm Diamètre - Diameter - Durchmeßer 85 mm Base - Base - Basis120 mm Poids - Weight - Gewicht 3.5 kg Options - Options - Optionen Capteur de température de soute à munitions - Ammunition storage temperature - Temperatursonde für Munitionskammer TEMPEX Valise de transport - Transportation case - Transportkoffer PELI Couleur - Color - Farbe Disponible dans les couleurs de la normes FED-STD-595B ou RAL selon les besoins spécifiques du client. Available according to FED-STD-595B or RAL colors or according to customer specific needs. Verfügbar in den Standardfarben FED-STD-595B oder RAL oder nach den spezifischen Bedürfnißen des Kunden. MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 9/38

7 Military products IRDAM MAWS6056BCGPS 125’060 Vitesse du vent - Wind Speed - Windgeschwindigkeit Plage de mesure - Range - Meßbereich m/s Précision - Accuracy - Genauigkeit± (0,5 m/s + 5%) Résolution - Resolution - Auflösung 0,1 m/s Direction du vent - Wind Direction - Windrichtung Azimut - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5.0° Résolution - Resolution - Auflösung 0,1° Direction de la station par rapport au Nord - Direction of the station to magnetic North - Stationrichtung bezugnehmend auf geographischen Norden Azimuth - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5° Résolution - Resolution - Auflösung 0.1° Température de l’air - Air Temperature - Lufttemperatur Plage de mesure - Range - Meßbereich - 40°C - +70°C Précision - Accuracy - Genauigkeit ± 1 °C Résolution - Resolution - Auflösung 0,1 °C Pression atmoshphérique absolue - Absolute Atmospheric Pressure - Absoluter Atmosphärischer Druck Plage de mesure - Range - Meßbereich hPa (mbar) Précision - Accuracy - Genauigkeit ± 5 hPa (mbar) Résolution - Resolution - Auflösung 0,1 hPa (mbar) Localisation GPS - Localization GPS - GPS Lokalisierung Latitude - Latitude - Breite90° N - 90° S Longitude - Longitude - Länge180° E - 180° W Précision - Accuracy - Genauigkeit variable Résolution - Resolution - Auflösung 1/512 min Option pour sonde de mesure externe - Connection for external intrument - Anschluß für externes Meßintrument Plage de mesure - Range - Meßbereich - 50°C °C Précision - Accuracy - Genauigkeit ± 0.3°C (-4 °C - +60°C) ± 1.2°C (+60°C °C) Résolution - Resolution - Auflösung 0,1°C Autotest - Autotest - Selbsttest Permanant - Permanent - Kontinuierlich Enclenchement - Start up - Inbetriebnahme < 20 s Protocole de sortie - Output protocol - Ausgangsprotokoll RS - 485, simplex MilCAN bus Cadence d’émission - Transmission cycle - Meßtakt 100 ms Alimentation - Input voltage - Stromversorgung V DC Consommation - Consumption - Leistungsaufnahme < 25 W Température d’utilisation - Operating temperature - Betriebstemperatur - 40°C °C Température de stockage - Storage temperature - Lagerungtemperatur - 55°C °C Dimensions - Size - Abmeßungen Hauteur - Height - Höhe550 mm Diamètre - Diameter - Durchmeßer 85 mm Base - Base - Basis120 mm Poids - Weight - Gewicht 3.5 kg Options - Options - Optionen Capteur de température de soute à munitions - Ammunition storage temperature - Temperatursonde für Munitionskammer TEMPEX Valise de transport - Transportation case - Transportkoffer PELI Couleur - Color - Farbe Disponible dans les couleurs de la normes FED-STD-595B ou RAL selon les besoins spécifiques du client. Available according to FED-STD-595B or RAL colors or according to customer specific needs. Verfügbar in den Standardfarben FED-STD-595B oder RAL oder nach den spezifischen Bedürfnißen des Kunden. MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 10/38

8 T-72 ARJUN LECLERC And many others…. Also upgrades worldwide … Ballistic applications 6056B LEOPARD 2 HEL (2A6EX) 6056BC 6056BCGPS M-60 Sabra MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 11/38 LEOPARD Next Gen MBT Upgrade Solution (2A4) ARJUN (Mk I & II)

9 Military products IRDAM MAWS6056H 125’060 Vitesse du vent - Wind Speed - Windgeschwindigkeit Plage de mesure - Range - Meßbereich m/s Précision - Accuracy - Genauigkeit± (0,5 m/s + 5%) Résolution - Resolution - Auflösung 0,1 m/s Direction du vent - Wind Direction - Windrichtung Azimut - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5.0° Résolution - Resolution - Auflösung 0,1° Température de l’air - Air Temperature - Lufttemperatur Plage de mesure - Range - Meßbereich - 40°C °C Précision - Accuracy - Genauigkeit ± 1 °C Résolution - Resolution - Auflösung 0,1 °C Pression atmoshphérique absolue - Absolute Atmospheric Pressure - Absoluter Atmosphärischer Druck Plage de mesure - Range - Meßbereich hPa (mbar) Précision - Accuracy - Genauigkeit ± 5 hPa (mbar) Résolution - Resolution - Auflösung 0,1 hPa (mbar) Humidité relative - Relative humidity - Luftfeuchtigkeit Plage de mesure - Range - Meßbereich 0% % Précision - Accuracy - Genauigkeit ± 4 % HR (0 % - 20 %) ± 3 % HR (20 % - 80 %) ± 4 % HR (80 % %) Résolution - Resolution - Auflösung 0,1 % HR Option pour sonde de mesure externe - Connection for external intrument - Anschluß für externes Meßintrument Plage de mesure - Range - Meßbereich - 50°C °C Précision - Accuracy - Genauigkeit ± 0.3°C (-40°C - +60°C) ± 1.2°C (+60°C °C) Résolution - Resolution - Auflösung 0,1°C Autotest - Autotest - Selbsttest Permanant - Permanent - Kontinuierlich Enclenchement - Start up - Inbetriebnahme < 20 s Protocole de sortie - Output protocol - Ausgangsprotokoll RS - 485, simplex MilCAN bus Cadence d’émission - Transmission cycle - Meßtakt 100 ms Alimentation - Input voltage - Stromversorgung V DC Consommation - Consumption - Leistungsaufnahme < 25 W Température d’utilisation - Operating temperature - Betriebstemperatur - 40°C °C Température de stockage - Storage temperature - Lagerungtemperatur - 55°C °C Dimensions - Size - Abmeßungen Hauteur - Height - Höhe550 mm Diamètre - Diameter - Durchmeßer 85 mm Base - Base - Basis120 mm Poids - Weight - Gewicht 3.5 kg Options - Options - Optionen Capteur de température de soute à munitions - Ammunition storage temperature - Temperatursonde für Munitionskammer TEMPEX Valise de transport - Transportation case - Transportkoffer PELI Couleur - Color - Farbe Disponible dans les couleurs de la normes FED-STD-595B ou RAL selon les besoins spécifiques du client. Available according to FED-STD-595B or RAL colors or according to customer specific needs. Verfügbar in den Standardfarben FED-STD-595B oder RAL oder nach den spezifischen Bedürfnißen des Kunden. MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 12/38

10 Military products IRDAM MAWS6056HC 125’060 Vitesse du vent - Wind Speed - Windgeschwindigkeit Plage de mesure - Range - Meßbereich m/s Précision - Accuracy - Genauigkeit± (0,5 m/s + 5%) Résolution - Resolution - Auflösung 0,1 m/s Direction du vent - Wind Direction - Windrichtung Azimut - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5.0° Résolution - Resolution - Auflösung 0,1° Direction de la station par rapport au Nord - Direction of the station to magnetic North - Stationrichtung bezugnehmend auf geographischen Norden Azimuth - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5° Résolution - Resolution - Auflösung 0.1° Température de l’air - Air Temperature - Lufttemperatur Plage de mesure - Range - Meßbereich- 40°C °C Précision - Accuracy - Genauigkeit± 1°C Résolution - Resolution - Auflösung 0,1°C Pression atmoshphérique absolue - Absolute Atmospheric Pressure - Absoluter Atmosphärischer Druck Plage de mesure - Range - Meßbereich hPa (mbar) Précision - Accuracy - Genauigkeit± 5 hPa (mbar) Résolution - Resolution - Auflösung 0,1 hPa (mbar) Humidité relative - Relative humidity - Luftfeuchtigkeit Plage de mesure - Range - Meßbereich 0 % % Précision - Accuracy - Genauigkeit ± 4 % HR (0 % - 20 %) ± 3 % HR (20 % - 80 %) ± 4 % HR (80 % %) Résolution - Resolution - Auflösung 0,1 % HR Option pour sonde de mesure externe - Connection for external intrument - Anschluß für externes Meßintrument Plage de mesure - Range - Meßbereich- 50°C °C Précision - Accuracy - Genauigkeit ± 0.3°C (-40°C °C) ± 1.2°C (+60°C °C) Résolution - Resolution - Auflösung 0,1°C Autotest - Autotest - Selbsttest Permanant - Permanent - Kontinuierlich Enclenchement - Start up - Inbetriebnahme < 20 s Protocole de sortie - Output protocol - Ausgangsprotokoll RS - 485, simplex MilCAN bus Cadence d’émission - Transmission cycle - Meßtakt 100 ms Alimentation - Input voltage - Stromversorgung V DC Consommation - Consumption - Leistungsaufnahme < 25 W Température d’utilisation - Operating temperature - Betriebstemperatur - 40°C °C Température de stockage - Storage temperature - Lagerungtemperatur - 55°C °C Dimensions - Size - Abmeßungen Hauteur - Height - Höhe550 mm Diamètre - Diameter - Durchmeßer 85 mm Base - Base - Basis120 mm Poids - Weight - Gewicht 3.5 kg Options - Options - Optionen Capteur de température de soute à munitions - Ammunition storage temperature - Temperatursonde für Munitionskammer TEMPEX Valise de transport - Transportation case - Transportkoffer PELI Couleur - Color - Farbe Disponible dans les couleurs de la normes FED-STD-595B ou RAL selon les besoins spécifiques du client. Available according to FED-STD-595B or RAL colors or according to customer specific needs. Verfügbar in den Standardfarben FED-STD-595B oder RAL oder nach den spezifischen Bedürfnißen des Kunden. MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 13/38

11 Military products IRDAM MAWS6056HCGPS 125’060 Vitesse du vent - Wind Speed - Windgeschwindigkeit Plage de mesure - Range - Meßbereich m/s Précision - Accuracy - Genauigkeit± (0,5 m/s + 5%) Résolution - Resolution - Auflösung 0,1 m/s Direction du vent - Wind Direction - Windrichtung Azimut - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5.0° Résolution - Resolution - Auflösung 0,1° Direction de la station par rapport au Nord - Direction of the station to magnetic North - Stationrichtung bezugnehmend auf geographischen Norden Azimuth - Azimuth - Azimut ° Précision - Accuracy - Genauigkeit± 5° Résolution - Resolution - Auflösung 0.1° Température de l’air - Air Temperature - Lufttemperatur Plage de mesure - Range - Meßbereich - 40°C °C Précision - Accuracy - Genauigkeit ± 1°C Résolution - Resolution - Auflösung 0,1°C Pression atmoshphérique absolue - Absolute Atmospheric Pressure - Absoluter Atmosphärischer Druck Plage de mesure - Range - Meßbereich hPa (mbar) Précision - Accuracy - Genauigkeit ± 5 hPa (mbar) Résolution - Resolution - Auflösung 0,1 hPa (mbar) Humidité relative - Relative humidity - Luftfeuchtigkeit Plage de mesure - Range - Meßbereich 0% % Précision - Accuracy - Genauigkeit ± 4 % HR (0 % - 20 %) ± 3 % HR (20 % - 80 %) ± 4 % HR (80 % %) Résolution - Resolution - Auflösung 0,1 % HR Localisation GPS - Localization GPS - GPS Lokalisierung Latitude - Latitude - Breite90° N - 90° S Longitude - Longitude - Länge180° E - 180° W Précision - Accuracy - Genauigkeit variable Résolution - Resolution - Auflösung 1/512 min Option pour sonde de mesure externe - Connection for external intrument - Anschluß für externes Meßintrument Plage de mesure - Range - Meßbereich - 50°C °C Précision - Accuracy - Genauigkeit ± 0.3°C (-40°C - +60°C) ± 1.2°C (+60°C °C) Résolution - Resolution - Auflösung 0,1°C Autotest - Autotest - Selbsttest Permanant - Permanent - Kontinuierlich Enclenchement - Start up - Inbetriebnahme < 20 s Protocole de sortie - Output protocol - Ausgangsprotokoll RS - 485, simplex MilCAN bus Cadence d’émission - Transmission cycle - Meßtakt 100 ms Alimentation - Input voltage - Stromversorgung V DC Consommation - Consumption - Leistungsaufnahme < 25 W Température d’utilisation - Operating temperature - Betriebstemperatur - 40°C °C Température de stockage - Storage temperature - Lagerungtemperatur - 55°C °C Dimensions - Size - Abmeßungen Hauteur - Height - Höhe550 mm Diamètre - Diameter - Durchmeßer 85 mm Base - Base - Basis120 mm Poids - Weight - Gewicht 3.5 kg Options - Options - Optionen Capteur de température de soute à munitions - Ammunition storage temperature - Temperatursonde für Munitionskammer TEMPEX Valise de transport - Transportation case - Transportkoffer PELI Couleur - Color - Farbe Disponible dans les couleurs de la normes FED-STD-595B ou RAL selon les besoins spécifiques du client. Available according to FED-STD-595B or RAL colors or according to customer specific needs. Verfügbar in den Standardfarben FED-STD-595B oder RAL oder nach den spezifischen Bedürfnißen des Kunden. MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 14/38

12 VABRECO FUCHS FOX VABRECO NBC Applications ADS-95 RANGER 6056HCGPS PIRANHA IIIC COBRA 6056H 6056HC FUCHS MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 15/38 And many others worldwide … PIRANHA 3 CBRN

13 FUCHS FOX UAV Recce Applications SPERVER ADS-95 RANGER 6056HC SPERVER ADS-95 RANGER MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 16/ BC 6056HCGPS 6056BCGPS

14 Military products Température d’utilisation - Operating temperature - Betriebstemperatur - 40°C °C Mesure de la température - Temperature measurement - Temperaturmeßung Plage de mesure - Range - Meßbereich- 40°C °C Précision - Accuracy - Genauigkeit± 0.3°C (-40°C - +60°C) ± 1.2°C (+60 °C °C) Résolution - Resolution - Auflösung 0,1°C Alimentation - Input voltage - Stromversorgung V DC ( ± 10%) Consommation - Consumption - Leistungsaufnahme < 1mA Temps de réponse - Response time - Reaktionszeit 20 s (T 0.9) Température de stockage - Storage temperature - Lagerungtemperatur - 40°C °C Classe de protection - Protection - Schutzklaße IP 65 Connecteur - Connector - Stecker Série SJTG / 8ST VG96912 Dimensions - Size - Abmeßungen Hauteur - Height - Höhe272 mm (10.70 inches) Diamètre - Diameter - Durchmeßer 33 mm (1.30 inches) Poids - Weight - Gewicht 0.3 kg (0.66 lbs) Options - Options - Optionen Valise de transport - Transportation case - Transportkoffer PELI Couleur - Color - Farbe Noir mat - Mat black - Matt Schwarz IRDAM TEMPEX 110’000 MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 17/38

15 Wind speed & Wind direction Compass / GPS Humidity Temperature Pressure Option for TEMPEX MILITARY AUTOMATIC WEATHER SENSORS Military products C:\MAWS 6056 presentation (may 2012).ppt page 18/38

16 Military products accessories IRDAM HOUSSE MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 19/38 IRDAM KITNBC6056B or H KITNBC6056 Replacement kit after decontamination of models IRDAM MAWS 6056 This kit allows, during decontamination operations, to replace the components affected by environmental conditions and ensure the sustainability of correct measurements. This replacement kit was developed and prepared for easy use on 1st maintenance level. It contains: ● 9 x screws M4x8 A2 LOB prepared with Tuflock anti-vibration glue ● 1 x pressure filter cap M5 prepared with Tuflock anti-vibration glue ● 1 x humidity filter cap This kit can be used with MAWS series 6056 type B, BC, BCGPS, H, HC or HCGPS. COVER A cover in stamoid® is available as an option to protect your MAWS from dirt and dust during transport or storage. ● excellent pliability over a wide temperature range ● flexible and rugged in durable applications ● anti-mildew treated and rot protected

17 MILITARY AUTOMATIC WEATHER SENSORS Military products MAWS & TEMPEX sizes C:\MAWS 6056 presentation (may 2012).ppt page 20/38

18 Integration Fire control system Ammunition storage room temperature transmited to the MAWS Ambiant temperature MAWS6056 Wind speed Pressure Humidity (1) GPS (3) Wind direction Legende: (1) if MAWS6056H (2) if MAWS6056BC or MAWS6056HC (3) if MAWS6056BCGPS or MAWS6056HCGPS All datas are sent in one message every 100 ms RS-422 or RS-485 Compass (2) TEMPEX MILITARY AUTOMATIC WEATHER SENSORS Specially designed for : - MBT’s - Medium and Small armored vehicles - Recce vehicles - AMPV - TSV C:\MAWS 6056 presentation (may 2012).ppt page 21/38

19 Integration MILITARY AUTOMATIC WEATHER SENSORS Specially designed for : - MBT’s - Medium and Small armored vehicles - Recce vehicles - AMPV - TSV C:\MAWS 6056 presentation (may 2012).ppt page 22/38

20 Integration Ambiant temperature MAWS6056 Wind speed Pressure Humidity (1) GPS (3) Wind direction Compass (2) Legende: (1) if MAWS6056H (2) if MAWS6056BC or MAWS6056HC (3) if MAWS6056BCGPS or MAWS6056HCGPS NBC suite RS-422 or RS-485 All datas are sent in one message every 100 ms TEMPEX Ground temperature transmited to the MAWS Or geographical analysis software MILITARY AUTOMATIC WEATHER SENSORS Specially designed for - NBC/CBRN vehicles C:\MAWS 6056 presentation (may 2012).ppt page 23/38

21 Integration MILITARY AUTOMATIC WEATHER SENSORS Specially designed for - NBC/CBRN vehicles C:\MAWS 6056 presentation (may 2012).ppt page 24/38

22 Integration MILITARY AUTOMATIC WEATHER SENSORS Specially designed for : - Mobile Operational Meteo Units - NBC / CBRN Shelters - UAV Shelters 24V Power Supply Display control system Or geographical analysis software All datas are sent in one message every 100 ms For - Wind direction and speed - Absolute atmospheric pressure - Ambiant temperature - Relative humidity (1) - Compass (2) - GPS (3) RS-422 or RS-485 C:\MAWS 6056 presentation (may 2012).ppt page 25/38 Legende: (1) if MAWS6056H (2) if MAWS6056BC or MAWS6056HC (3) if MAWS6056BCGPS or MAWS6056HCGPS

23 Integration MILITARY AUTOMATIC WEATHER SENSORS Specially designed for : - Art or MLRS, HIMARS, etc… - Art targets obs vehicles (or UGV) 24V Power Supply Display control system (Win PC) All datas are sent in one message every 100 ms For - Wind direction and speed - Absolute atmospheric pressure - Ambient temperature - Relative humidity (1) - Compass (2) - GPS (3) RS-422 or RS-485 C:\MAWS 6056 presentation (may 2012).ppt page 26/38 Legende: (1) if MAWS6056H (2) if MAWS6056BC or MAWS6056HC (3) if MAWS6056BCGPS or MAWS6056HCGPS

24 Integration MILITARY AUTOMATIC WEATHER SENSORS Especially designed for : - Art or MLRS, HIMARS, etc… - Ground-Air defence - Art targets obs vehicles (or UGV) C:\MAWS 6056 presentation (may 2012).ppt page 27/38

25 Military products Duration in years Delivery to customer Factory’s warrantyE x t e n s i o n o f t h e f a c t o r y ‘s w a r r a n t y Option block 3 Option block 1 Option block 2 Recalibration & new Test Report Calibration & Test Report MILITARY AUTOMATIC WEATHER SENSORS A factory warranty up to 12 years and Including a recalibration every 3 years C:\MAWS 6056 presentation (may 2012).ppt page 28/38

26 Military products MILITARY AUTOMATIC WEATHER SENSORS A full set of documentation: - Technical Manual 6056 & TEMPEX - Service Manual 6056 & TEMPEX - Individual Test Report - CoC - Warranty C:\MAWS 6056 presentation (may 2012).ppt page 29/38

27 800 m 2 of high technology and competence IRDAM factory MILITARY AUTOMATIC WEATHER SENSORS C:\MAWS 6056 presentation (may 2012).ppt page 30/38

28 Léonard SCHLAEPFER Co-CEO Finances, HR, & Marketing Daniel HENRARD Co-CEO R&D and Operation Director Denis Buffat Sales Engineer Fabrice Zambano Sales Engineer Mechanical engineers Prototype & construction Electronic engineers Boards prototype Informatics engineers Software design Electronic assembly Quality control & Assembly Final tests Calibration & test reports Outsourcing: - Mechanics - Electronic boards - Painting Documentations Mechanical assembly Customers' acquisition & Follow up Exhibition organisation & Product marketing 27% of the staff in R&D department Organigram Technological survey Quality Management Customer After Sales MILITARY AUTOMATIC WEATHER SENSORS Purchase C:\MAWS 6056 presentation (june 2013).ppt page 31/38

29 Wind speed errors vs wind speed MILITARY AUTOMATIC WEATHER STATIONS Military products C:\MAWS 6056 presentation (may 2012).ppt page 32/38

30 Wind direction errors vs direction Wind speed errors vs direction MILITARY AUTOMATIC WEATHER STATIONS Military products C:\MAWS 6056 presentation (may 2012).ppt page 33/38

31 Wind speed vs wind direction MILITARY AUTOMATIC WEATHER STATIONS Military products C:\MAWS 6056 presentation (may 2012).ppt page 34/38

32 Accuracy Reliability Manufacturing quality Low maintenance Compact building No moving parts Integrated compass Integrated GPS Individual calibration Individual test reports Quality control Production process control Finished product control Team of specialists All IRDAM products Undergo an individual, very stringent quality control based on : Are well known for their : MILITARY AUTOMATIC WEATHER STATIONS Military products C:\MAWS 6056 presentation (may 2012).ppt page 35/38

33 Precision and know-how “Made in Switzerland” Weather sensors adapted to your specific needs Reliable even in the extreme situations Our technical office is at your disposal for a turn-key solution Combat proven MILITARY AUTOMATIC WEATHER SENSORS Military products C:\MAWS 6056 presentation (may 2012).ppt page 32/38

34 MILITARY AUTOMATIC WEATHER SENSORS THANK YOU ! C:\MAWS 6056 presentation (may 2012).ppt page 38/38


Download ppt "IRDAM SA Presents Military products Meteorology for winners! May 2012."

Similar presentations


Ads by Google