Presentation is loading. Please wait.

Presentation is loading. Please wait.

1. 2 Spare part stockCalibration room Headquarters Goteborg, Sweden, founded 1979 Sensor development Manufacture & assembly Marketing and Sales Service.

Similar presentations


Presentation on theme: "1. 2 Spare part stockCalibration room Headquarters Goteborg, Sweden, founded 1979 Sensor development Manufacture & assembly Marketing and Sales Service."— Presentation transcript:

1 1

2 2 Spare part stockCalibration room Headquarters Goteborg, Sweden, founded 1979 Sensor development Manufacture & assembly Marketing and Sales Service

3 Global organisation Headquarters in Gothenburg. -Management -Development -Production -Service NA office in Charlotte, NC -Sales -Service Offices in the UK, Germany and Finland.

4 PreciCura SR/MR/LR

5 MR= Measurement Range SO= Stand-Off distance CE= SO=Xmin=Close End Sensor output=MR FE= SO+MR=Xmax=Far End Sensor output=0 CE Xmin FE Xmax Definitions

6 Technical specifications: Measurement Range (MR):100 … 8000 mm CCD array: 2000 pixels. Resolution: MR / 32000 (16 x sub-pixel) Power supply: +24 VDC (18-32 VDC) Diode laser: 1 to 20 mW Laser class: 2, 2M, 3R or 3B Wave length: 635-670 nm Measuring frequency: 2000 Hz Working temperature: 0 – 40  C PreciCura SRPreciCura MRPreciCura LR 162 x 108 x 42 mm303 x 149 x 57 mm524 x 149 x 57 mm 1,0 kg3,0 kg5,0 kg The PreciCura family

7 Serial RS232 HOST (MR/LR only) up to 115200 bit/s ASCII - FORMATS CAN-bus Field bus system up to 1 Mbit/s (Bus length 40 m) up to 250 Kbit/s (Bus length 200 m) Real time bus system to combine with PLC, Encoder… Analog 16 bit 0…20 mA or 4…20 mA C1: serial RS232 service interface C2: Main connector, Power supply CAN-bus and Analog interface C3: Serial RS232 HOST interface and sensor synchronization Interfaces

8 Delivery includes: - Manual in English - 2 meter cable for the C2 connector - Serial RS232 interface for setup and service - CAN-bus and Analog (0 or 4 to 20 mA) interface PreciCura SR

9 Options: 3-point bracket:Mounting bracket for easy fine adjustment of the sensor. PreciCuraSet:Windows® based setup software. Incl. 5 meter cable to PC. Air knife:For compressed air. Blower unit:Front mounted. For fan driven air. Calibration fixture:Rotating calibration target on an arm. Ideal for thickness calibration. Cooling box (Air):Protective enclosure with fan driven air cooling connection.

10 Delivery includes: - Manual in English - 2 meter cable for the C2 connector - Serial RS232 interface for setup and service - CAN-bus, Analog (0 or 4 to 20 mA) and serial RS232 HOST interface PreciCura MR

11 Options: Measurement Range:100 < MR < 2000 mm, resolution 0,01 or 0,1 mm depending on MR Mounting bracket:Mounting bracket for easy fine adjustment of the sensor. PreciCuraSet:Windows® based setup software. Incl. 5 meter cable to PC. Air knife:For compressed air. Blower unit:Front mounted. For fan driven air. Cooling box (Air):Protective enclosure with fan driven air cooling connection.

12 Delivery includes: - Manual in English - 2 meter cable for the C2 connector - Serial RS232 interface for setup and service - CAN-bus, Analog (0 or 4 to 20 mA) and serial RS232 HOST interface PreciCura LR

13 Options: Measurement Range:600 < MR < 8000 mm, resolution 0,1 or 1 mm depending on MR Mounting bracket:Mounting bracket for easy fine adjustment of the sensor. PreciCuraSet:Windows® based setup software. Incl. 5 meter cable to PC. Air knife:For compressed air. Blower unit:Front mounted. For fan driven air. Cooling box (Air):Protective enclosure with fan driven air cooling connection.

14 Protection and cooling box Brackets Calibration unitBig display PreciCuraSet Accessories

15 - Rugged, industrial design - No moving parts - Not sensitive for colour variations - Center-of-Gravity evaluation of measured distance and 16-times subpixel => increased resolution and accuracy - CCD evaluation of distance => less sensitive for dirt on the front glasses, secondary reflections and background radiation - No extra control unit Benefits

16 Target: rotating white paper Target: white paper, not moving Speckle effect

17 Filter algorithms: AverageFilter length: 2-1000 (Filter length = 1 => No filter). Data output rate is reduced proportional to the Filter length. Moving AverageFilter length: 2-1000 (Filter length = 1 => No filter). Data output rate is NOT reduced by the Filter length. MedianSorting the content of the data buffer. Normally uses the middle value of the buffer as output. Can also be used as a min/max filter. Eliminates spikes in the data. Filters

18 Control of data input to the filter: - ContinuousFixed filter length (settable between 1-1000). - TrigThe filter length is controlled by the leading (positive) flanks of the trigger input. - GateThe filter length is controlled by the leading and trailing flanks of one trig pulse. - Self trigThe Filter length is controlled by the internal error messages in the sensor (Valid data/”NO OBJECT”) i.e. the measurement target controls the filter length. (e.g. in thickness measurement applications of a board).

19 Upper PreciCura Lower PreciCura CAN-bus Conn. box Upper PreciCura: Measuring mode:Distance CAN bus ID:101 Filter type:Averaging Filter Length:1 Synchronization mode:Slave (option) Lower PreciCura: Measuring mode:Thickness CAN bus ID:100 Filter type:According to application Filter Length:According to application Synchronization mode:Master (option) Outputs available:CAN-bus, Analog, Serial RS232 Thickness measurement Power CANbus (Synch) Power Output

20 Thank you


Download ppt "1. 2 Spare part stockCalibration room Headquarters Goteborg, Sweden, founded 1979 Sensor development Manufacture & assembly Marketing and Sales Service."

Similar presentations