Presentation is loading. Please wait.

Presentation is loading. Please wait.

TFX Ultra Clamp-on Ultrasonic Flow Meter. Model TFX Ultra  Rugged, all inclusive output options  Compact integral mount system for pipes 2” (50.8 mm)

Similar presentations


Presentation on theme: "TFX Ultra Clamp-on Ultrasonic Flow Meter. Model TFX Ultra  Rugged, all inclusive output options  Compact integral mount system for pipes 2” (50.8 mm)"— Presentation transcript:

1 TFX Ultra Clamp-on Ultrasonic Flow Meter

2 Model TFX Ultra  Rugged, all inclusive output options  Compact integral mount system for pipes 2” (50.8 mm) and smaller  Remote mount system for pipe sizes ½” (12.7 mm) and higher Integral mount shown here. Integral transducers available in PVC (standard) or optional CPVC

3 New generation of transit time flow meter: Increased transmit power by over 3x Compatible with ALL transducer types (do not need separate boards) USB interface to PC (for UltraLink software) Backlit LCD Easier wiring (compared with TFXL) CE mark  1% of reading accuracy Measuring range -40 – 40 FPS (-12 – 12 MPS) NEMA 4 (IP65); aluminum enclosure CSA Class I Div. 2 / ATEX II 2 G Ex nA II T4 TFX Ultra Features

4 Other Notable Features/Improvements:  Standard A/B USB programming connection  Field replaceable fuse (resettable on DC powered)  Optional keypad  Universal AC (95-230VAC) power option  Display backlighting  Keypad/UltraLink configure for 500 kHz, 1 MHz or 2 MHz transducers  Remote totalizer reset (via ModBUS, N.O. switch, or IP if equipped)  “GREEN” utilizes less than 5 watts (typical, 3x less than Onicon) TFX Ultra

5 Flow Meter Model Two Transmitter Types: Energy Model (BTU)

6 Outputs & Communications  Standard  Energy and Flow Meter Models  4-20mA (sourcing)  RS485 Modbus RTU Communications (2-wire)  Flow Meter Model only, also has:  Frequency Output (1000 Hz, open-collector)  Dual Alarm Outputs; high/low flow, batch, errors (open-collector)  Optional  Ethernet: Modbus TCP/IP, EtherNet/IP and BACnet/IP  Totalizing Pulse Output; isolated open-collector

7 TFX Ultra Optional TFXB is available with Intrinsically Safe barrier, CSA Class I Div. 1

8 DTTS  ½” to 2” (12 to 50 mm)  Easy/quick installation, transducers custom fit to ANSI pipe, Copper Tubing, or Rigid Tubing specs  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67)  Available in PVC for maximum fluid temperature +185 °F (+85 °C)  And CPVC for maximum fluid temperature +250 °F (+121 °C)  ½” and ¾” versions are 1% F.S. accuracy Transducer Options

9 DTTN  Pipe sizes 2” [50 mm] and above  Versatile mounting options  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67); optional NEMA 6P (IP-68)  Maximum fluid temps to +250 °F (+121 °C) Transducer Options

10 DTTH  High Temp: maximum fluid temps to +350 °F (+176 °C)  Pipe sizes 2” [50 mm] and above  Versatile mounting options  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67)  Includes high-temp couplant

11 Transducer Options DTTL*  Pipe sizes 24” [610 mm] and above  Versatile mounting options  Cable lengths to 990 ft (300 meters)  Flexible armored conduit option  Rated to NEMA 6 (IP-67); optional NEMA 6P (IP-68)  Maximum fluid temps to +250 °F (+121 °C)  Also recommended for pipe sizes 4”-24” (100-610 mm), if application parameters are not ideal. * Used with TFX Ultra and DXN only, 500 kHz configuration

12 Applications Conserve Thru Control North Adams, MA Geo Thermal Application TFX Ultras used to measure and control geo-thermal HVAC system. EPA also requires building owner to report ground water usage. Well water can carry dirt and ice which destroys inline meters.

13 Client: Valley Water – Plainville, CT. Municipal Water Application High velocity – no straight runs TFX Ultra replaced 901 Doppler Result: Improved accuracy Applications

14 P&G Gillette Beauty & Grooming Boston, MA Gillette’s sustainability project requires measurement and control of city water and process loops in 100 year old plant. Potential sale for 17 measurement points. Most lines cannot be shut down without halting production. Applications

15 Ulster Uniform Service Kinston, NY Industrial Laundry Since a high percentage of the water is evaporated through their dryers, Ulster uses a TFX Ultra meter to report waste water usage to save on their sewage bill. Applications

16 Mercedes-Benz plant, Istanbul, TURKEY Challenge: Customer dissatisfied with in-line BTU meters to measure energy use through their 15 cogeneration lines. Considered to be high maintenance and were not thought to be reliable. Solution: TFXE w/ DTTN, Clamp-on RTDs Easy installation, no process shut-down, and seamless drop-in to their Siemens SCADA system via standard Modbus RTU were seen as key advantages in selecting Dynasonics.

17

18

19

20 Genoa, Illinois WWTP Use clamp-on meters to prove output and performance of new pump; DFX Doppler and Transit time TFX Ultra both utilized, due to suspected pump cavitation. Meters showed a disparity, helped identify debris caught within the pump.

21

22 Thank you +44 (0)1280 817304 sales@bellflowsystems.co.uk www.badgermeter.co.uk Bell Flow Systems are the UK representative for Badger Meter