1 Wall / V 12 V 12 Introduction Arguments Technical details Installation

2 The V 12 range V 12 / Introduction Introduction Arguments
The V 12 range includes 2.5, 3.5, 5.0 and 6.5 kW mono split units, as well as 2x1 multi splits. All of them working with ON-OFF technology. V 12 models have a modern design with a new bright digital display. Moreover, it includes an enhanced health air purifying system, and functions such as Low Noise, Sleep Function and Light Control. Type Power Model Single ON-OFF 025 V W 035 V W 050 V W 065 V W Multi 2x1 ON-OFF V M2W Introduction Arguments Technical details Installation

3 V 12 / Arguments / Features
HIGH EFFICIENCY DC INVERTER REMOTE CONTROL COLORFUL LCD DIGITAL DISPLAY BIO BACTERIA KILLING LOW NOISE SLEEP FUNCTION COLD CATALYST FILTER TIMER AUTO OPERATION 2x1 DUST FILTER VERTICAL AIR SWING LIGHT CONTROL Modern Design The series comes with elegant blue color display which provides useful information for the user. Air purifying This series includes a complete health air purifying system consisting of three filters; a cold catalyst filter, a bio filter and 2x1 anti dust filter. High Comfort Customer focused design and improved functions like Low noise and Vertical air swing provide more comfort to end users. High Efficiency The majority of the range is A class energy efficiency. Our DC Inverter Solution – Inverter Technology High modulating DC Inverter technology provides high efficiency, low sound and high comfort. Introduction Arguments Technical details Installation

4 Modern design V 12 / Arguments / USPs Arguments Introduction
Easily controlled by remote control With several functions including green light ON-OFF function on indoor display. New display Bright digital display with elegant blue colour provides users with useful information such as Operation mode, Sleep function and Set temperature. It is a clear differentiation when compared with more simple LED lamps displays. Introduction Arguments Technical details Installation

5 Air purifying V 12 / Arguments / USPs Arguments Introduction
Anti dust 2x1 filter This filter neutralizes and protects the ambient air from acarus, microbes and dust through its unique 2 in 1 effect (it is also antiallergenic and antibacterial). Bio filter A layer of special material is installed in the filtration network of the unit. When the unit starts working, slow release technology purifies the ambient air, providing moisturization and improving health effects on the skin. Cold catalyst filter This filter has anti-odour and sterilization effects. It can completely degrade methyl oxide (which has cancerogenic effects) from the ambient air. It also effectively removes odd odours like those of methyl hydrosulfate, ethyl mercaptan etc. Compared with optical catalyst filters, the cold catalyst has the advantage of recycling without going through the regeneration process. Introduction Arguments Technical details Installation

6 Comfort V 12 / Arguments / USPs Arguments Introduction
Customer focused design provides more comfort to end users. Special functions such as Sleep function, Auto operation, a complete Health Air Purifying system, Light control via remote button, Universal indoor and Low noise are designed to bring comfort to the final users. HEALTH AIR PURIFYING LIGHT CONTROL AUTO (it is possible to choose the temperature in this mode) SLEEP LOW NOISE Introduction Arguments Technical details Installation

7 High efficiency V 12 / Arguments / USPs Energy Cost Savings Arguments
‘A’ Class range provides optimum comfort with minimum consumption of energy. More efficient Energy Cost Savings More efficient More savings Less efficient Less efficient Less savings Introduction Arguments Technical details Installation

8 V 12 / Technical Details / Technical Specifications
Feature Units Model V W V W V W V W Indoor Unit V HWI V HWI V HWI V HWI Outdoor Unit V HWO V HWO V HWO V HWO Power supply V/Ph/Hz 230/1/50 Cooling capacity kW 2.86 3.21 5.40 6.70 BTU 9,761 10,955 18,429 22,866 Power Input 0.89 1.00 1.68 2.09 EER Energy level class A Heating capacity 2.95 3.43 6.06 7.05 10,068 11,706 20,682 24,060 Power input 0.81 0.94 2.05 COP 3.64 3.65 3.61 3.44 B Air flow volume m3/h 355/391/450 391/455/500 672/736/800 708/804/900 Catalogue sound pressure IU dB(A) 28/34/40 29/35/40 32/39/43 33/40/44 Catalogue sound pressure OU 50 53 Compressor type Rotary Expansion system Capillary Introduction Arguments Technical details Installation

9 V 12 / Technical Details / Technical Specifications
Feature Units Model V M2W Indoor Unit 1 & 2 V MHWI & V MHWI Outdoor Unit V M2NHWO Power supply V/Ph/Hz 230/1/50 Cooling capacity kW 5.80 BTU 19,794 Capacity by indoor 1 & 2 2.60 & 3.20 Power Input 1.71 EER 3.39 Energy level class A Heating capacity 6.38 21,774 2.86 & 3.52 Power input 1.86 COP 3.44 B Air flow volume 1 & 2 m3/h 300/400/500 & 300/400/500 Catalogue sound pressure IU 1 & 2 dB(A) 28/34/40 & 28/34/40 Catalogue sound pressure OU 52 Compressor type Rotary Expansion system Capillary Introduction Arguments Technical details Installation

10 V 12 / Technical Details / Temperature range
Model Cooling (ºC) Heating (ºC) Indoor low Outdoor low Outdoor high Indoor high V W 16 8 43 32 -7 V W V W V W V M2W Introduction Arguments Technical details Installation

11 V 12 / Technical Details / Drawings
Indoor dimensions Outdoor dimensions Model HxLxD (mm) Weight (kg) V HWI 250x745x195 9 V HWI V HWI 292x900x215 14 V HWI V MHWI 280x800x190 10 V MHWI Model HxLxD (mm) – I/J (mm) Weight (kg) V HWO 500x700x225 – 260/510 25 V HWO 540x795x255 – 280/510 36 V HWO 38 V HWO 605x850x295 – 305/500 45 V M2HWO 645x925x430 – 400/692 64 Introduction Arguments Technical details Installation

12 Mono split V 12 / Installation Installation Introduction Arguments
Model Units V W V W V W V W Pipe connection liq/gas inches 1/4” – 3/8” 1/4” – 1/2” Max. pipe length m 20 25 Max. height IU under OU 10 15 Max. height OU under IU Refrigerant type gr R410A Refrigerant charge 560 1,120 1,500 1,900 Additional charge per meter 28 40 50 Max. Pipe Length = a + b + c = a + d + e Max. Height IU under OU = h2 Max. Height OU under IU = h1 Introduction Arguments Installation Technical details

13 Multi split V 12 / Installation Installation Introduction Arguments
Model Units V M2W Pipe connection liq/gas IU 1 & 2 inches 1/4”–3/8” & 1/4”–1/2” Pipe connection liq/gas OU Max. pipe length m Max. height IU under OU 10 Max. height OU under IU Refrigerant type gr R410A Refrigerant charge 1, ,200 Additional charge per meter Total Max. Length = L1 + L2 + L3 Max. Height IU under OU = h2 Max. Height OU under IU = h1 L1 = a + b + c L2 = d L3 = e + f + g Max. single pipe length = L1 = L2 = L3 Introduction Arguments Installation Technical details

14 Controls / Remote controls / Description / V 12
Increases/Decreases the temperature by 1ºC and sets the timer Switches the device ON-OFF Selects the mode: AUTO/COOL/DRY/HEAT/FAN Directs the airflow up/down Directs the airflow up or down Adapts the temperature during night time Selects the Timer start-up time Starts working at maximum fan speed Activates the ion operation (function not available) Switches off the light of the indoor display Locks the remote control button