Presentation is loading. Please wait.

Presentation is loading. Please wait.

UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product.

Similar presentations


Presentation on theme: "UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product."— Presentation transcript:

1

2 UNICO INVERTER DC

3 UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product will be available in 4 different models 1. UNICO INVERTER DC 9 SF 2. UNICO INVERTER DC 9 HP 3. UNICO INVERTER DC 12 SF 4. UNICO INVERTER DC 12 HP

4 UNICO INVERTER DC Main technology innovations Design (King & Miranda)
1. Outstanding quiet operation 2. High performance and efficiency 3. High air flow and air distribution 4. Installation Reduced installation time needed High and low installation configuration 5. Easier maintenance 6. Advanced air filters 7. Low ambient control Design (King & Miranda)

5 + = 1 – OUTSTANDING QUIET OPERATION Unico Inverter DC
1 Unico Star The new Unico Inverter DC’s noise level will be half the current UNICO Star

6 = 2 – HIGH PERFORMANCE DC INVERTER Technology
The inverter control system constantly regulates the compressor motor speed, adapting it to the actual cooling or heating needs of the room Inverter technology Max Comfort = Keeps the set temperature without oscillations Reaches the set temperature faster Low energy consumption (reduction up to 30%) Low noise level

7 2 – HIGH PERFORMANCE

8 2 – HIGH PERFORMANCE

9 Cooling UNICO INVERTER vs Competitors
2 – HIGH PERFORMANCE Cooling UNICO INVERTER vs Competitors Classe A EER Kw

10 2 – HIGH PERFORMANCE Heating UNICO INVERTER vs Competitors Classe A
Classe B COP Kw

11 3 – HIGH COMFORT INCREASED AIR FLOW IMPROVED AIR DISTRIBUTION 520 cm/h
The air distribution has been improved increasing the size of the air outlet to 690 x 60 mm

12 4 - INSTALLATION UNICO INVERTER UNICO STAR
Can be installed high wall or low wall Can be installed high wall or low wall FOR HIGH WALL INSTALLATION Change the position of the air outlet flap, and press a key on the LED panel FOR HIGH WALL INSTALLATION Dismount plastic shell Invert position of air outlet parts Move LED and fan cap Installazione bassa TIME NEEDED 1 minute TIME NEEDED 20 minutes Installazione alta Particolare flap uscita aria

13 4 – INSTALLATION Suggested holes are of 202 mm Ø for higher performances, but the unit can works with 162mm Ø holes as well. Unico Inverter DC back

14 4 – INSTALLATION It is very easy to operate the unit with 200 mm holes. The unit is factory fitted to work with 160 mm holes, if necessary. First hole: remove the pre-cut plastic Second hole: behind the rear panel there is a polistyrene cylinder that reduces the size of the hole. Simply remove it. The distance between the center of the holes remains the same as the UNICO Star. This easily allows replacing old Unico Star units with the new Unico Inverter.

15 4 – INSTALLATION The minimum top/bottom and side allowances have been reduced. Unico Inverter can be installed in small niches where it was not possible to install Unico Star.

16 5 – Easier maintenance The accessibility to the internal parts have been improved. It is easier to dismount and service the single components of the unit. REAR PART FRONT PART

17 5 – Easier maintenance REAR PART
The back of the unit is made by two panels LEFT PANEL Encloses the: - coil zone - compressor - drain exhaust system RIGHT PANEL Encloses the condenser fan group,. Removing some screws the whole fan group can be removed to be more easily serviced.

18 5 – Easier maintenance FRONT PART
The front part has a big frontal panel. When you remove it, you find two smaller panels. LEFT PANEL Removing it you can access to the electric board RIGHT PANEL Removing it you can access to - compressor - external coil probe - drain exhaust system

19 6 – ADVANCED AIR FILTERS Electrostatic filter: removes small particles and smoke, dust, pollen, pet hair, preventing allergy issues Active carbon filter: removes smells and deactivates harmful gases Cleaning: The air inlet grills are very easy to dismount Air inlet-outlet flaps closed Air inlet-outlet flaps open

20 This makes UNICO a perfect solution for server rooms.
7 – LOW AMBIENT CONTROL UNICO Inverter can work in cooling mode with outside temperature up to -10C°! This makes UNICO a perfect solution for server rooms.

21 TECHNICAL DATA Unico inverter 12 SF Cooling capacity (min-nom-max)
1800 – 2700 – 3100 Watt Heating capacity / E.E.R. 2,7 C.O.P. Cooling energy efficiency class A Heating energy efficiency class Size in mm (wxhxd) 902 x 506 x 230 Weight (kg) 40 Walls hole size Noise level TBD Unico inverter 12 HP Cooling capacity (min-nom-max) Watt Heating capacity Watt E.E.R. 2,7 C.O.P. 3,2 Cooling energy efficiency class A Heating energy efficiency class Size in mm (wxhxd) 902 x 506 x 230 Weight (kg) 40 Walls hole size Noise level TBD Unico inverter 9 SF Cooling capacity (min-nom-max) 1400 – 2300 – 2700 Watt Heating capacity / E.E.R. 2,7 C.O.P. Cooling energy efficiency class A Heating energy efficiency class Size in mm (wxhxd) 902 x 506 x 230 Weight (kg) 40 Walls hole size Noise level TBD Unico inverter 9 HP Cooling capacity (min-nom-max) 1400 – 2300 – 2700 Watt Heating capacity 1400 – 2400 – 2700 Watt E.E.R. 2,7 C.O.P. 3,2 Cooling energy efficiency class A Heating energy efficiency class Size in mm (wxhxd) 902 x 506 x 230 Weight (kg) 40 Walls hole size Noise level TBD NB: all the data shown in this presentation must be considered as preliminary

22 ACCESSORIES IN THE BOX TEMPLATE 2 INTERNAL FLANGES
PAIRS OF EXTERNAL GRILLS (200 mm) NEW PP SHEETS TO USE FOR 200 mm HOLES (but suitable for 160mm holes as well)


Download ppt "UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product."

Similar presentations


Ads by Google