1 Date TEMPERATURE CONTROL SYSTEM

2 2 Division Appareillage et Système Résidentiels Choosing different temperature or different profile on different room (zone) it is possible to reduce the consumption: -switching OFF the unused zone -take advantage by the sun heating -adjusting the fan speed automatically etc. Introduction

3 3 Division Appareillage et Système Résidentiels COMMERCIAL Where we can sell the Thermo regulation system RESIDENTIAL Apartments Shops Restaurant Villas Offices Introduction

4 4 Division Appareillage et Système Résidentiels Introduction Heating Cooling Cooling/Heating Radiators Radiant panel Fan Coil

5 5 Division Appareillage et Système Résidentiels With ON/OFF contact Elettrovalvole/pompe utilizzabili The proportional valves can’t be managed by My home temperature control system. With Open&Close contact PUMP (ON/OFF)

6 6 Division Appareillage et Système Résidentiels 6 Catalogue  Power supply and accessories  Temperature central unit  Probes  Actuators  Contact interface (OPTIONAL) PROBES ACTUATORS LOADS CENTRAL UNIT Hydraulic circuit

7 7 Division Appareillage et Système Résidentiels System block diagram Central Unit Actuators Probe Loads Hydraulic circuit Catalogue

8 8 Division Appareillage et Système Résidentiels HC/HD/HS/L/N/NT 4695 4 zones Temperature control unit able to manage 3550 99 zones temperature control Catalogue

9 9 Division Appareillage et Système Résidentiels Mutizone system (max 4 zones) Zone 3 Zone 4 4 zones central unit Zone 2 It allows to manage the temperature control systemtill 4 zones (one is the central unit). It is compulsory to have the progressive numbering in configuration sockets Catalogue

10 10 Division Appareillage et Système Résidentiels Ref. 3550 Central unit to manage the temperature control system with max. 99 zones (wall mounted enclosure). Catalogue

11 11 Division Appareillage et Système Résidentiels Probes..4693 room temperature control probe for heating and cooling systems - temperature adjustment range 3-40 °C (it has also the SLAVE mode)..4692 room temperature control probe for heating and cooling systems with knob for ― 3 °C manual local adjustment of the temperature, compared with the centrally set temperature and for the selection of the OFF and antifreeze modes …4692FAN room temperature control probe for heating and cooling systems with knob for ― 3 °C manual local adjustment of the temperature, compared with the centrally set temperature and for the selection of the OFF and antifreeze modes with selection of the manual/automatic fan-coil speed Catalogue

12 12 Division Appareillage et Système Résidentiels It can be a master probe of the temperature control system: FUN = 3 → with local probe FUN = 4 → with slave probe Ref.3457 radio probe to measure the external temperature - use with radio receiving interface item HD/HC/HS4577 - power supply with solar cells or battery - wall mounted enclosure IP65 Catalogue LOCAL DISPLAY RADIO PROBE

13 13 Division Appareillage et Système Résidentiels Actuators F430/2 actuator with 2 independent relays – for single and double loads: 6A resistive, 3A motorised valves and pumps – logical interlock of the relays by means of configuration. F430/4 actuator with 4 independent relays - for single, double or combined loads: 4A resistive, 1A motorised valve, pumps and fan-coil – logical interlock of the relays by means of configuration Catalogue

14 14 Division Appareillage et Système Résidentiels Additional temperature system controls This controls enables monitoring the temperature of the whole house, adjusting it according to the zone, based on actual requirements. Catalogue

15 15 Division Appareillage et Système Résidentiels E46ADCN L4669 e L4669/500 CONFIGURATORS Accessories Catalogue Contact interface

16 16 Division Appareillage et Système Résidentiels CONFIGURATION Configuration

17 17 Division Appareillage et Système Résidentiels Probes addressing mode [ ZA ] and [ ZB ] are the sockets for the probe address (01 to 99): (only numerical configuration). ZB ZA n n Configuration

18 18 Division Appareillage et Système Résidentiels Probes..4692 e..4692FAN ZA n ZB n SLA n Configuration Probe..4693 Master probe Slave probe ZA nn ZB nn CEN MOD CENSLA n*n**

19 19 Division Appareillage et Système Résidentiels 19 MASTER SLAVE 1 SLAVE 2 ZA=1 ZB=2 SLA=2 ZA=1 ZB=2 MOD=SLA SLA=1 ZA=1 ZB=2 MOD=SLA SLA=2 T=18°C T=18,5°C T=19°C ZONE 12 Configuration

20 20 Division Appareillage et Système Résidentiels Actuators addressing mode. n n ZB ZA N n Zone adddress linked to its probe. Progressive numbering of contact (load) in the same zone. Configuration

21 21 Division Appareillage et Système Résidentiels F430/2 F430/4 F430/2 ZA n ZB1 n CEN N1 CEN n n ZB2 CEN N2 CEN n F430/4 ZA n ZB1 n CEN ZB2 CEN n n ZB3 CEN n N n ZB4 Configuration

22 22 Division Appareillage et Système Résidentiels Probe and its actuator ZB ZA ZB ZA N 0 1 0 1 1 Configuration

23 23 Division Appareillage et Système Résidentiels 23 Configuration Number of load inside the zone ZAZB1N1ZB2N2 0÷9 1÷9OFF - 0÷9OFF - 1÷9 NUMBER OF ZONE OPEN/CLOSE 2 INTERLOCKED RELAIS 2 INTERLOCKED RELAIS ZB1=ZB2 ON/OFF ZB1≠ZB2 2 INDEPENDENT RELAIS 2 INDEPENDENT RELAIS

24 24 Division Appareillage et Système Résidentiels ZAZB1ZB2ZB3ZB4N 0÷91÷9OFF - 1÷9 1÷9 Number of load inside the zone OPEN/CLOSE 2 RELAY INTERLOCK ZB1=ZB2 and ZB3=ZB4 ON/OFF ZB1≠ZB2≠ZB3≠ZB4 4 INDEPENDENT RELAYS NUMBER OF ZONE FAN COIL ZB1=ZB2=ZB3=ZB4 1 RELAY ON/OFF 3 RELAYS FAN SPEED Configuration

25 25 Division Appareillage et Système Résidentiels 4 zones central unit It is also a local probe (this is the reason of the configuration sockets). Configuration ZAn ZBn SLAn*

26 26 Division Appareillage et Système Résidentiels The central unit is a first zone of the system and the other three zones have to configured in progressive numbering (like the example above). Probe ZA0 ZB4 Probe ZA0 ZB3 Probe ZA0 ZB2 Centrale ZA0 ZB1 Configuration

27 27 Division Appareillage et Système Résidentiels 4 zones central unit & Tithermobasic Configuration

28 28 Division Appareillage et Système Résidentiels 99 zones central unit Probe ZA0 ZB1 Probe ZA0 ZB2 Probe ZA9 ZB9 Configuration

29 29 Division Appareillage et Système Résidentiels 99 zones central unit & Tithermo Configuration

30 30 Division Appareillage et Système Résidentiels The integration between MY HOME Burglar-Alarm and Temperature Control systems allows the set-up of a particularly useful function in terms of energy saving, avoiding the lost of energy to the outside, for example switch OFF the zones when someone open the windows. PS. Available only on the 99 zone central unit. Example of integration between temperature Control and Automation Configuration

31 31 Division Appareillage et Système Résidentiels INSTALLATION RULES AND LIMITS

32 32 Division Appareillage et Système Résidentiels System limits DISTANCE ABSORPTION ADDRESS LOGICAL LIMIT PHYSICAL LIMIT Installation rules and limits

33 33 Division Appareillage et Système Résidentiels Free BUS cabling topology Star connectionsFree connection Just one rule: no closed ring! Installation rules and limits PHYSICAL LIMIT

34 34 Division Appareillage et Système Résidentiels Power supplyActuatorControl 250m MAX500m MAX Installation rules and limits PHYSICAL LIMIT

35 35 Division Appareillage et Système Résidentiels Calculate the absorption of the system: PHYSICAL LIMIT Max 1200mA IF THE THERMOREGULATION AND AUTOMATION USES SAME BUS, YOU HAVE ALSO TO ADD THE ABSORTIONS OF THIS DEVICES Installation rules and limits

36 36 Division Appareillage et Système Résidentiels 4 zones 9 contact (load) for each zone 9 Pump Installation rules and limits LOGICAL LIMIT

37 37 Division Appareillage et Système Résidentiels 99 zones 9 contact (load) for each zone 9 Pump LOGICAL LIMIT Installation rules and limits

38 38 Division Appareillage et Système Résidentiels EXAMPLES

39 39 Division Appareillage et Système Résidentiels Pump connection ON/OFF valve connection Example

40 40 Division Appareillage et Système Résidentiels OPEN/CLOSE valves connection Example

41 41 Division Appareillage et Système Résidentiels 2 pipes fan coil connection Example

42 42 Division Appareillage et Système Résidentiels 4 pipes fan coil connection Example

43 43 Division Appareillage et Système Résidentiels 4 zones villa – radiator heating system Example

44 44 Division Appareillage et Système Résidentiels 12 offices – heating and cooling with Fan Coil Example