R Value of Wall Improvement BRENO BONDARENKO COSTA ARCH 3630 PROF. APTEKAR & PROF AZAROFF.

Similar presentations


Presentation on theme: "R Value of Wall Improvement BRENO BONDARENKO COSTA ARCH 3630 PROF. APTEKAR & PROF AZAROFF."— Presentation transcript:

1 R Value of Wall Improvement BRENO BONDARENKO COSTA ARCH 3630 PROF. APTEKAR & PROF AZAROFF

2 IECC & ASHRAE Maps

3

4 Average Temp & Precipitation Irvine, CA

5 Average Temp & Precipitation for NYC

6 Existing Conditions- Stevens Identifying Material 1/4” Cement Board Siding 1 3/16” Substructure Thermal Barrier ¾” Plywood Close Cell Spray Foam R30 2x6” Stud Wall Awning Window by Pella 5/8” GWB Phase Change Material(PCM)

7 Existing Conditions – References R Value

8

9 Existing Conditions – R Value of Wall 2x6” Wood Stud=6.875 Closed Cell Foam R30=38.4 5/8” GWB with PCM=0.569 ¾” Plywood=0.95 Window by Pella=2.75 ¼” Cement Siding=0.13 Total=49.674 The addition of all the R values of the wall materials does not surpass the 50 minimum for an excellent insulation.

10 Proposed Changes – Stevens 2x6” Wood Stud=6.875 Closed Cell Foam R30=38.4 5/8” GWB with PCM=0.569 ¾” Plywood=0.95 Window by Pella=2.75 ¼” Cement Siding=0.13 2” Air Space @ Insulation=1.13 Total=50.804 By simply adding a 2” air space at insulation on the outside part of the wall, the R value of the wall increases and surpasses the 50 minimum required.

11 Existing Conditions- SCIAL/CalTech Identifying Materials Structural Steel Framing 4x6 (wood) Beam 2x12 (wood) beam (6”)Batt Insulation (5/8”) Plywood Sheathing Sprayed Insulation

12 Existing Conditions – Reference R Value

13 Existing Conditions – R Value of Wall Structural Steel Framing=0.541 4x6 (wood) Beam=5.4 2x12 (wood) beam=16.875(12”x12”) (6”)Batt Insulation=19.0 (5/8”) Plywood Sheathing=0.94 Sprayed Insulation @ 3”=2.4(@2.4 per12”h) Sprayed Insulation @ 6”=4.8(@2.4 per 12”h) Total=49.956 The total addition of the R values of the wall is a little bellow the recommended. Although, there is a thermal bridge connecting the roof to the wall making this number go down quite a bit and diminishing the ability for the wall to insulate the building.

14 Proposed Changes – R Value of Wall Structural Steel Framing=0.541 4x6 (wood) Beam=5.4 2x12 (wood) beam=16.875(12”x12”) (6”)Batt Insulation=19.0 (5/8”) Plywood Sheathing=0.94 Sprayed Insulation @ 6”=4.8(@2.4 per12”h) Total=52.356 By adding sprayed insulation around the steel structural framing, it eliminates the thermal bridge, increasing the R value, therefore, insulating the building better.

15 References http://www.weather.com/weather/wxclimatology/monthly/graph/USNY0996 http://www.weather.com/weather/wxclimatology/monthly/92697 Building System: Mechanical, Electrical, Plumbing, Fire Safety & Communication Systems, Lighting & Acoustics Educational book by Wendell C. Edwards http://archtoolbox.com/materials-systems/thermal-moisture-protection/24-rvalues.html http://rvalue.net/page2.html http://apps1.eere.energy.gov/buildings/publications/pdfs/building_america/4_3a_ba_innov_buildingscienceclimatemaps_011713.pdf http://www.jameshardie.com/pdf/esr-1844.pdf http://www.springfieldmo.gov/taskforce/greenbuild/pdfs/rValRequireASHRAE90.1.pdf