Presentation is loading. Please wait.

Presentation is loading. Please wait.

Flash and FOIL® Frame Wall Insulation. Module 1 Masonry Wall Insulation Hybrid Spray Foam and Reflective Insulation System – Fi-Foil® Company Introduces…

Similar presentations


Presentation on theme: "Flash and FOIL® Frame Wall Insulation. Module 1 Masonry Wall Insulation Hybrid Spray Foam and Reflective Insulation System – Fi-Foil® Company Introduces…"— Presentation transcript:

1 Flash and FOIL® Frame Wall Insulation

2 Module 1 Masonry Wall Insulation Hybrid Spray Foam and Reflective Insulation System – Fi-Foil® Company Introduces…

3 What is Flash & Foil? Fi-Foil’s new Flash & Foil Frame Wall Insulation is an improved insulation solution designed to save you money. This solution has advantages to Flash and Batt systems. Combine Fi-Foil’s VR Plus Shield® Reflective Insulation with spray foam insulation to reduce costs and provide code-compliant R-Values in any frame wall construction. Drop the Batt - Flash & Foil™! Flash & Foil™ is a National Solution for Frame Wall Foam Insulation

4 Why replace fiberglass batt with Fi-Foil’s VR Plus Shield® Reflective Insulation? 1)Code Compliant Wall R-Values…R-values for Flash & Foil in 2 x 4 inch wall range from R-11 to R-19, based on the foam manufacturer’s R per inch and the thickness of the foam. A complete table of R-Values determined by the thickness and type of spray foam to follow on separate slide (Table 1). 2)Less Cost… typical savings of 25% versus fiberglass batts. 3)Stops Radiation…as a reflective insulation, VR Plus Shield’s multiple layers separate to create three reflective air spaces to virtually eliminate heat transfer. 4)Less Storage Space…500 square foot rolls are easy to store and transport. 5)Vapor Retarder…available in Hi-Perm (perforated version) that allows vapor transmission and in Standard (non-perforated version) that functions as a vapor retarder, if required by code. 6)Green Building Material…contributes to Green Building Certification credits for Energy Efficiency.

5 VR Plus has a Class A Flammability Rating Also available in Hi-Perm (perforated version) to allow vapor transmission or in Standard (non-perforated version) to perform as a vapor retarder. Offered in 16” and 24” width rolls with tape tab for installing over Metal Framing or with staple tab for Wood Framing.

6 How does Flash & Foil™ work? Step 1: Spray the desired thickness of foam insulation on the inside of the frame wall which seals the joints and provides thermal protection by reducing air infiltration and adding thermal resistance. Instead of 3-1/2” or 5-1/2” of spray foam in a 2 x 4 inch or 2 x 6 inch cavity respectively, a thinner layer of foam (flash) is used to air seal the cavity. Step 2: Apply VR Plus Shield reflective insulation (foil) to the face of the studs. The three layers of VR Plus Shield expand to form reflective air spaces in the remaining portion of the 2 x 4 inch or 2 x 6 inch cavity. REQUIRES 1-1/2 INCH AIR SPACE FOR VR PLUS TO EXPAND INNER LAYERS

7 How are R-Values calculated for Nominal 2 x 4 inch and 2 x 6 inch Wood Frame Wall Cavities insulated with VR Plus Shield® and Spray-applied Cellular Foam Plastic Insulation? The thermal resistance (R-values) for combinations of Fi-Foil VR Plus Shield Reflective Insulation and spray-applied cellular foam plastic insulation have been calculated using a procedure published in ASTM STP 1116. Figure 1. Top View of Wall Cavity with Foam and Reflective Insulation Assembly Exterior Sheathing 1” Spray Foam VR Plus Shield Hi-Perm (requires minimum 1-1/2” air space) 3 ½” Studs 24” on Center

8 2x4 Frame Walls2x6 Frame Walls System Inches of Spray FoamFoam R Reflective System RTotal R * Reflective System RTotal R * Foam R*=6.0 2"127.42197.6620 1.5" 98.09177.4116 1.0" 67.64147.1613 Foam R*=5.0 2"107.39177.5618 1.5" 7.58.02167.3115 1.0" 57.57137.1012 Foam R*=3.5 2"77.33147.4014 1.5" 5.257.87137.1912 1.0" 3.57.44117.0011 Table 1. R-Values for Flash & FOIL™ Frame Wall Application R* - thermal resistance per inch of thickness: ft²·h·°F/Btu · in R - thermal resistance: ft²·h ·° F/Btu * - rounded in accordance with FTC Rule 460 (R-Value Rule) (All cavity R-Values are reported in customary U.S. units at mean temperature of 75°F)

9 Flash & FOIL Thermal Performance with Closed Cell Foam *1” Closed Cell Foam R - 6 R - 14 VR Plus Shield Hi-Perm R - 7.6 *2” Closed Cell Foam R - 12 R - 19 VR Plus Shield Hi-Perm R - 7.4 Flash & FOIL Thermal Performance with Closed Cell Foam *1” Closed Cell Foam R - 6 R - 14 VR Plus Shield Hi-Perm R - 7.6 *2” Closed Cell Foam R - 12 R - 19 VR Plus Shield Hi-Perm R - 7.4 Flash & FOIL™ Thermal Performance with Closed Cell Foam 1” of Closed Cell Foam R – 6.5 R – 14 VR Plus Shield® Hi-Perm R - 7.6 2” of Closed Cell Foam R - 13 R – 20 VR Plus Shield® Hi-Perm R - 7.4 Closed Cell Foam now available in R-6.5

10 Flash & FOIL™ Frame Wall Application 2” x 4” or 2” x 6” Frame Walls OSB VR Plus Shield Hi-Perm (adds at least R-7.0) 2” Spray Foam (2 lb. or Closed Cell) Reflective Air Spaces Reflective Air Space (determined by depth of framing and thickness of foam)

11 Overall Benefits of Flash & Foil™ Spray Foam Seals Wall Cavities Reduces Air Infiltration Adds a High R-Value per inch VR Plus Shield Reflective Insulation No Fibers Cost-effective Vapor Retarder Option Meets Code Compliance Simple Installation Process! Class A Flammability Rating