Muon barrel cooling G. Aielli and J. Godlewski LS1 TC planning.

Slides:



Advertisements
Similar presentations
Using Ground Source Heat Pump The Avenue Centre.
Advertisements

Refrigerators. Reversing the Flow Heat flow through an engine was used to generate work. Heat flow through an engine was used to generate work. Work can.
Air Conditioners and Heaters
Conduction Conceptests
TYPES OF MECHANICAL SYSTEMS
Chapter 6 Thermal Energy
Section 16.3 Using Heat.
Lesson 10 How can you reduce radon in a home? Slide 10-1 Brief overview of radon mitigation Mitigation: reducing radon in air or water Requires trained,
Heat and States of Matter
18th March Richard Hawkings Humidity control in the ATLAS ID Richard Hawkings (CERN) JCOV meeting 18/3/04  Overview of humidity and associated gas.
ATLAS muon chambers heat transfer efficient description RFNC – VNIITF SUE «Strela» Snezhinsk, 2003
Science project By Dillon Williams And. Vocab Section 1 - Temperature of an object is a measure of the average kenetic energy of the particles in the.
Building for the Future By: Green inc.. Location Colorado Springs, Colorado Outskirts of Colorado springs Average temperature of winter is 18* Summer.
High Density Cooling Air conditioning for high density applications
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
CFD team supports CERN development 19 May M.Battistin CERN May 19 th 2011 C omputational F luid D ynamics team C omputational F luid D ynamics team.
Shielding the Weiner PSU 7 May 2013 Kiril Marinov ASTeC, MaRS, DL 1.
Shielding the Turbomolecular Pump: an update 14 May 2013 Kiril Marinov ASTeC, MaRS, DL 1.
Upgrade news and Proposed interventions during YETS for the Muon Barrel Alignment Szillási Zoltán, Béni Noémi (ATOMKI ) This project is supported by Hungarian.
Pixel Support Tube Requirements and Interfaces M.Olcese PST CDR: CERN Oct. 17th 2001.
Thermal Energy and heat
ATLAS EXPERIMENT INTEGRATION TASK: SPACE MANAGEMENT Tatiana Klioutchnikova 05/06/
EN-CV status EHN1 Extension Project Jérôme Rodary EN-CV-PJ 2015/08/06.
ATLAS Calorimeter Argon Gap Convection Test Bed Brian Cuerden 24 Apr
Section 1 Temperature and Heat. Kinetic Theory  All objects (even people) are made of particles and atoms that constantly and randomly move. All atoms.
5.3 Essential Questions What are the first and second laws of thermodynamics? How does an internal combustion engine work? How does a refrigerator work?
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 28/7/2009 Already presented by C. Martel/ J Inigo Golfin on15 th October 2008 CLIC WORKSHOP.
1 H. Pernegger/CERNIBL cooling review 15/5/2012 IBL Cooling Requirements H. Pernegger.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
TOF Gas System Project Overview. Content Prototype for Aging tests done for RPC’s TOF Gas System: parameters and module layouts. Special Technology: channel.
JCOV, 25 OCT 2001Thermal screens in ATLAS Inner Detector J.Godlewski EP/ATI  ATLAS Inner Detector layout  Specifications for thermal screens  ANSYS.
Section 3 Using Heat.
ATLAS TRT CO 2 cooling system project status Beaufort 12: “Hurricane” (>119 km/h) Saffir-Simpson 5: “catastrophic damage” (>250 km/h) (CO 2 distribution.
N.Delruelle, 22th-26th September 2008 Cryogenics Operations 2008, CERN, Geneva, Switzerland 1 CRYOGENICS OPERATIONS 2008 Organized by CERN Design choices.
SEPTEMBER 2002 Pixel Support Tube A. Smith LBNL 1 ATLAS Pixel Detector Heater Panel Testing Alexis Smith September 17, 2002.
AGROTOP Poultry Construction
October 18, Muon Meeting B. Schmidt Outline: Installation schedule under Discussion Status of Integration activities Possible modifications to the.
TC Straw man for ATLAS ID for SLHC This layout is a result of the discussions in the GENOA ID upgrade workshop. Aim is to evolve this to include list of.
1 13 Octobre 2011 Laurent Roy ATCA Crate / Infrastructure in place -Rack in D3: dimension -Electrical power availability -Tell1 racks running in D3 (air.
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL CERN TS/CV Wednesday 9 th July 2008 CLIC.
Additional muon stations for the Upgrade of the Elevator Regions in the ATLAS Muon Spectrometer. Installation scenario, status on the installation tools.
EN-CV Progress EHN1 Extension Project Jérôme Rodary EN-CV-PJ 2016/01/21.
1 A Self-Cooled Lithium Blanket Concept for HAPL I. N. Sviatoslavsky Fusion Technology Institute, University of Wisconsin, Madison, WI With contributions.
1 Antonio Romanazzi 3D CFD study of the ATLAS (UX15) ventilation system.
Experimental hall in Japanese mountain site 2011/11/30 Yasuhiro CFS Webex meeting 1.
Power, Cooling, Cables, Simulations of Heat Dissipation Short overview of ongoing work on these points Technical Coordination (Rolf Lindner et al.) Cooling.
 Welcome & introduction  Health & safety  Mobile ‘phones  Agenda.
Using Thermal Energy Mrs. Nell 8 th Grade Physical Science Chapter 6 Review.
Technical Design for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
LHCb Muon Station Cooling Studies (done by Ricardo Antunes Rodrigues (ST/CV)) This simulations were made for the Muon Station 1, with the follow assumptions:
August 2007Andrea Gaddi, CERN Physics Dept. Detectors Infrastructures & Services Baseline to design detectors infrastructures. Tentative arrangement of.
EN-CV Progress EHN1 Extension Project Jérôme Rodary EN-CV-PJ 2016/01/14.
Energy and Heat. What is Energy? When something is able to change its environment or itself, it has energy Energy is the ability to change Energy has.
Chapter 16 Thermal Energy and Heat
- STT LAYOUT - SECTOR F SECTOR A SECTOR B SECTOR E SECTOR D SECTOR C
Additional muon stations for the Upgrade of the Elevator Regions in the ATLAS Muon Spectrometer. Integration issues Denis Diyakov, Alexander Seletskiy,
ATLAS ITk CO₂ Cooling pipe routing CO₂ Meeting, 28 June 2016
COOLING & VENTILATION INFRASTRUCTURE
ATLAS ITk CO₂ Cooling pipe routing Common Mechanics meeting
Section 3: Using Thermal Energy
5.3 notes What are the first and second laws of thermodynamics?
Notes 7: Using Heat Chapter 6 Section 3 Page 172.
Bell work Predict whether leaving the refrigerator door open on a hot summer day will help to cool the kitchen.
Installation plans from mid 2005
______________ Combustion Engine
Thermal behavior of the LHCb PS VFE Board
Presentation transcript:

Muon barrel cooling G. Aielli and J. Godlewski LS1 TC planning

Problem overview Cooling of the barrel toroid region. Definition of the problem a)Heat sources inside uniformely distributed (with exceptions) b)Barrel toroid tight chamber layout insulates it from the external ventilation c)Excess of temperature gradient due to stratification and convection 9°C from bottom to top (19 to 28°C) d)Excess of average temperature 24°C instead of 20°C e)Lowest temperature on TGCs (endcaps) 17°C Cathegory of interventions: 1.Local removal or shielding of the heat produced (a,b,c) 2.Geographical redistribution of the cooling power (b,c,e) 3.Overall increase of the cooling power (a,d)

Heat removal The trade off is to remove the heat of localized strong sources The removal of the distributed heat produced by each chamber has a limited result with respect to the resouces needed Targets highlighted: – PP2 is shielded but the shielding is not very efficient – There is a big mass of TRT power cables below PP2 at about 30°C which can be reduced/shielded – 22 diffusion pumps for the toroid coils very hot >50°C and unshielded New Muon chambers (they are blocking air flow). Once more we can not count on diffusion from outside to the inside of the barrel

Cooling power distibution Global intervention strategy: – Reduce as much as possible the EC outlets vent air flow and increase the HS outlets  done already. The main target of this intervention is to reduce the TGC sensitivity to the injected cold air – Remove cold air from the source and actively inject in the barrel. There are 2 installations already in place with different strategy: Ventilation pipe in sector 13 is taking cold air «for free» with a pump from the Level0 air, being already cold enough. The advantage is that you can have as much as you want without implication on the cavern ventilation system (ans safety…) Ventilation pipe installed at Level 8 on top of the detector, driving air directly from the top ventilation ducts. This is done passively at the moment and the air is injected in the most heated sectors on top. – Both these installations can be improved in therm of total cooling delivered and distribution

Sector 13 ventilation pipe Side c view The air is injected in sec. 13 BM and distributed along Z This is not optimal since this part is already cold The proposal is to bring the air as UP as possible toward sectors 1 and 9 BM and traslate the distribution pipe accordingly Optimal position to be defined

Top sector ventilation pipe Proposed modification to the present system: – Increase the overall air flow by applying fan inside the pipes. This can have concern ATLAS ventilation system and require discussion with EN-CV group – Make a finer distribution according to the scheme on the next slide. In facts we measure highly scattered temperature values on the top sectors depending on the diffusor position Top view Cold air Air diffusor

Proposal for air distribution in Muon Barrel sector 5 Fresh air into gaps between BML sector 5 and BMS sector 4 and 6 through perforated 200 mm ducts Fresh air into central part of the sector mm main duct There should be symmetrical arrangement for sides A and C We should also check that the cold air impacts on the lower plane of the BML of sector 5

Increase of the cooling power This can be done by – Increasing the total air change rate, presently m^3/h. This could allow to increase the amount of gas deviated from the main ducts to the top sectors – Lowering the input temperature as much as possible compatibly with the TGC safety. – It seems there is room enough for bo the interventions