Single-Axis Tilt-Sensor Systems Harry M.M. Kerkvliet and Gerard C.M. Meijer  Soz 2004.

Slides:



Advertisements
Similar presentations
Nonlinear Compact Thermal Model of SiC Power Semiconductor Devices Krzysztof Górecki, Janusz Zarębski, Damian Bisewski and Jacek Dąbrowski Department of.
Advertisements

Salinity Sensor. Calibrated Solution and Electrode - 50,000uS/cm from YSI Incorporated - 50,000uS/cm from YSI Incorporated - Electrode apart - 1.3cm -
1 IV. Electrodes In order to measure biopotentials, we must convert the ionic activity of the excitable cells of interest to electrical signals. In order.
1/27 Precision PositioningCapacitive Distance Sensors for Wijnand Harmsen, PME – Mechatronic System DesignJune 28 th, 2010 The Excessive Humidity Effect.
3441 Industrial Instruments 1 Chapter 2 Analog Signal Conditioning
ELECTROMAGNETIC CANNON. Question  A solenoid can be used to fire a small ball. A capacitor is used to energize the solenoid coil. Build a device with.
Novocontrol Alpha Analyzers Fundamentals
A novel model for blood impedance for indirect viscosity measurement Zu-yao Chang, Gerard C.M. Meijer and Gheorghe A.M. Pop Faculty of Electrical Engineering,
Applied Sensor Technology. Outline Introduction Examples of Sensors Basic readout electronics Semiconductor detectors.
TCS3 Encoder Review Web Page Reference Requirements APE (Absolute Position Encoder)–
A.Chupyra IWAA10, DESY Hamburg, September 13-17, BINP CAPACITIVE AND ULTRASONIC HYDROSTATIC LEVEL SENSORS A.G. Chupyra, G.A. Gusev, M.N. Kondaurov,
Pressure Measurement Why is it important?. Pressure Measurement Asses the situation –What is the range of pressures to be measured? –Is pressure dynamic.
Midterm Review MBS 2006 MP Electronics, Basic Concept  Two modules:  Probe module  Surface module  The surface module is replaced by the.
Lecture 3: Bridge Circuits
EKT314/4 Electronic Instrumentation
EKT314/4 Electronic Instrumentation
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
EMMA Electrical Engineering July 06 EE & PS Group EE & PS Group – EMMA 06
Wireless Intelligent Sensor Modules for Home Monitoring and Control Presented by: BUI, Phuong Nhung, 裴芳绒 António M. Silva1, Alexandre Correia1, António.
ELECTRICAL B 2  Storage batteries store electrical energy due to the chemical action taking place between electrodes and electrolytic solution. 
Whole Body Pethysmography H Measures body volume by air displacement –actually measures pressure changes with injection of known volume of air into closed.
Abstract The purpose of this project was to design a LabVIEW program that can be used as a platform to simultaneously interface Lakeshore 331 Temperature.
Performance characteristics for measurement and instrumentation system
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
Design of Capacitive Displacement Sensors for Chip Alignment
9AEI It is defined as the change of position of a body with respect to a reference It may be Linear motion Rotational motion Displacement.
Radiation Detectors Khayrudinov Vladislav Ismail Belmostefa XX00AA Sensor Technology Helsinki Metropolia University of Applied Sciences 2014.
Design of a readout system for RPCs Olu Amoda2 The LODEN Group The group is an association of Fermilab scientists who teamed up to build a cosmic ray.
Electrocorticography-Based Brain Computer Interface – The Seattle Experience.
Integrated Smart Sensor Calibration Abstract Including at the sensor or sensor interface chip a programmable calibration facility, the calibration can.
C We have to solve the time independent problem H o  o = E o  o Harry Kroto 2004.
IN THE NAME OF GOD. Magnetic position sensor Ehsan Peymani Golnaz Habibi.
1 Nicolo Cartiglia, INFN, Torino - RD50 - Santander, 2015 Timing performance of LGAD-UFSD 1.New results from the last CNM LGAD runs 2.A proposal for LGAD.
Lecture 3: Bridge Circuits
URL: 12-1, Hisakata 2-chome, Tempaku-ku, Nagoya JAPAN (C)2001 Manufacturing Engineering Laboratory,
The Avengers.  Measure ozone concentration as it relates to temperature from ground level to approximately 100,000 ft. above sea level.  Using this.
Displacement and Motion Measurement
Delft University of Technology Low-cost Capacitive Personnel Detector R.N. Aguilar,, M. Roelofsz, H. Kerkvliet, R. van de Ven, G.C.M. Meijer Electrical.
12 September 2006Silicon Strip Detector Readout Module J. Hoffmann SIDEREM SIlicon Strip DEtector REadout Module.
Factors influencing the conversion efficiency of a PV module Vaal University of Technology Augustine Ozemoya Vaal University of Technology Augustine Ozemoya.
Alignment Meeting, CERN, Sept 19, 2006O.Prokofiev 1 EMU Alignment System Analog Data Analysis for ME+1yME+4 Stations Run: Aug 25-28, 2006 Magnetic field.
16 Sept PSD 7 Liverpool 1 MHSP with position detection capability MHSP with position detection capability H. Natal da Luz a,b, J.F.C.A. Veloso a,b,
Properties of the bakelite used for standard RPC chambers as a function of the operating temperature F. Bruni – G. Hull – S.M. Mari 4 digital thermometers.
A WIRELESS PASSIVE SENSOR FOR TEMPERATURE COMPENSATED REMOTE PH MONITORING IEEE SENSORS JOURNAL VOLUME 13, NO.6, JUNE 2013 WEN-TSAI SUNG, YAO-CHI HSU Ching-Hong.
Tiltmeter, Compass,Temperature modules for the PPM.
实验十四 紫外线灭菌  一、实验背景及目的:  灭菌是一种杀灭微生物的措施。紫外线灭菌 是物理灭菌因素之一。  1. 了解紫外线灭菌的原理;  2. 学习、掌握紫外线灭菌的方法。 版权所有 未经作者同意 请勿使用.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
Ammeter voltmeter cell Indicator / light source diode Light emitting diode resistor Variable resistor thermistor Light dependent resistor heater Electric.
Magnet and ferrites tests Luciano Elementi Mu2e Extinction Technical Design Review 2 November 2015.
Displacement, Location or Position Sensor Muhajir Ab. Rahim School of Mechatronic Engineering, KUKUM.
The reading is 7.38 mm. The reading is 7.72 mm.
Performance of the PHENIX NCC Prototype Michael Merkin Skobeltyn Institute of Nuclear Physics Moscow State University.
10 mm is the same as... 1 cm. 20 mm is the same as... 2 cm.
Digital Temperature Sensor AS6200 for customer
(2) Bridge Circuits.
Electronic Instrumentation Lectrurer Touseef Yaqoob
Mechanical Measurement Lab, EDMS no
Prepared by T Vigneshkumar S Vijayakumar
CAPACITANCE SENSOR.
Capacitance Variations
Need for Alignment Position of off-momentum proton w.r.t. beam
MicroE Systems Mercury II™ Family of Encoders
HVCMOS Detectors – Overview
Radiation Detection via Transition Edge Sensor (TES)
On this basis, a new geometry with silicon short strip sensors (strixels) is proposed. In order to understand the behaviour of such devices, test geometries.
724 Temperature Calibrator
Fig. 2 Experimental setups for spin caloritronic measurements.
TAL227 PARALLEL BEAM LOAD CELL
BME680 HUMIDITY SENSOR EDDIE SHEA RUCHEN TANG SEAN SWALVE.
Presentation transcript:

Single-Axis Tilt-Sensor Systems Harry M.M. Kerkvliet and Gerard C.M. Meijer  Soz 2004.

Tilt sensors with electronic readout Improved accuracy Data storage Applicable in control loops

System set-up Resistive element Capacitive element

Resistive element Null impedance 1000  Null repeatability  3 arcsec Operating temperature –20 0 C to C

Connection with interface

Experimental results Resolution: 1 arcsec for measurement time of 1 s

Capacitive elements Advantages - non- invasive - low-cost

Interface

Experimental results for the capacitive sensor Resolution: 4 arcsec for measurement time of 1 s

Conclusions Two types of electronic tilt sensors have been implemented, using –resistive electrolytic elements –capacitive elements The resistive elements show a good linearity and a high resolution The capacitive sensors have the advantage of non-invasive electrodes, but the electrode structure should be improved

Questions ?  Soz 2004.