World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training,

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
RJ Mann Catalytic Monitoring Systems. RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
MCS-Connect Intro to Connect Connection and Setup Display Menus Graphics Uses in troubleshooting Overview.
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
Multi-DNC Data Collection/Monitoring
Invensys  D irect D igital C ontrol. Invensys  Direct Digital Control : 1.Hardware. 2.Software. 3.Firmware. 4.Local DDC Controllers. 5.Types of I/O.
1 Why use Modbus Master Provide Archive history for Non Archiving Units Remote Archiving for Large Frame products –Currently manual operation. Master Communications.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
BCAL Interlock System US BCAL Chiller US BCAL MPOD 1 US BCAL PLC Pulsed Output from Flow meter to PLC From US BCAL cooling loop US BCAL MPOD 1 RS485 from.
Remote Monitoring and Management Solutions ®
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Finding That Elusive Pot of Gold or Networking Your Shelter Rebecca Peltzer & Jennifer Bradley, Polk County – Air Quality Steve Drevik, Agilaire.
Applying Wireless in Legacy Systems
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Monitoring systems COMET types MS55 & MS6 MS55/MS6 Configuration.
SCADA and Telemetry Presented By:.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
Introduction Mobile Switch is a device which will be helpful to switch on and off any electrical/electronic devices through a SMS. The parameters of these.
Looking for a more powerful circuit monitor?
GasGard® XL Monitor.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
10/5/ InstantHMI Designed for Watlow Beam the Palm at your Watlow SD controller and voila!, you have a low cost HMI for Configuration, Diagnosis,
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
Router Fundamentals PJC CCNA Semester 2 Ver. 3.0 by William Kelly.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions PID Control (P)roportional (I)ntegral Internal Stat PID (D)erivative Further.
World Leaders in Combustion Management Solutions Training School Autoflame Training 2013 PID.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
World Leaders in Combustion Management Solutions Taiwan introduction.
World Leaders in Combustion Management Solutions ModuleScreenshots Normal Operation Features Commissioning The Mk7 MM System.
SmartMQn Motor Horner APG, LLC September 9, 2008.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (D.T.I.) THE MK7 DATA TRANSFER.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
Cscape EnvisionRV Horner APG, LLC. EnvisionRV - What Does it Do? Allows viewing and interacting with remote OCS controllers. The PC displays screens that.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Autoflame Training 2014.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
World Leaders in Combustion Management Solutions ModuleScreenshots Gas Setup Sampling The Mk7 E.G.A Cell Status Further Information.
Intelligent Boiler Sequencing
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
World Leaders in Combustion Management Solutions Mini Mk7 Evolution Autoflame Training Mini Mk.7 Evolution.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
Water Horner APG, LLC June 4, What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured.
CEA DSM Irfu SIS LDISC 18/04/2012 Paul Lotrus 1 Control Command Overview GBAR Collaboration Meeting Paul Lotrus CEA/DSM/Irfu/SIS.
CX5A PC Programmable with 2-RS232 Ports. CX5A  Product Description A wall mounted UHF Alphanumeric, Numeric and Tone/Vibrate only Local Area Paging Transcoder.
Rohde & Schwarz Topex TOPEX IP Radio Gateway July 2011.
Programmable Controllers - ECL/ECB
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
World Leaders in Combustion Management Solutions OverviewExplanationFurther Information Application Further Information Explanation Introduction Application.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Overview Of Autoflame. Schedule Overview of Autoflame products – MM Controls: Mk8 & Mini Mk8 – Exhaust Gas Analyser (EGA) – Data Transfer Interface (DTI)
Kessler-Ellis Products
SIO-RTD RTD MODULE.
Presentation transcript:

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training, 2011 Remote Monitoring & Data Logging

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Protocols Modbus Johnsons Metasys Ports RS232 (10m) RS422 (1km) RS485 (Metasys) Internal modem Operation Supervisor Manager (modem) Data Transfer Interface Module

D.T.I. Arrangement Mk.7 M.M.

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Remote Monitoring & Control Data Transfer Interface (D.T.I.) Gateway for communications Modbus and Metasys protocols How many units per D.T.I.? –10 MM units –10 stand-alone EGA units –10 analogue I/O units –10 digital I/O units

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Control Functions Boiler enable/disable command Change setpoint- individual and global Select lead boiler Shuffle sequencing –User-selectable lead/lag control Remote firing rate adjustable –Anticipate load requirements –Individual and global

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI MM Output/Status Values Boiler control type (pressure/temperature) Required boiler setpoints (temperature/pressure) Actual boiler temperature/pressure Burner operation status (on/off/vps/purge/modulation) Burner firing rate Auto/hand/low flame hold Fuel selected Channel positions Sequencing optioned/enabled/status

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI E.G.A. Outputs E.G.A. operation Commissioned values Actual values Exhaust temperature reading Error conditions

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Relevant Options/Parameters Option 16: sequencing D.T.I. Operation –0- no sequencing –1- sequencing enabled –2- setpoint & enable/disable commands –3- both 1 & 2 Option 30/31: setpoint limitations –Additional safety –Effects data-logging graphical display Option 33: identification number

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Set-up Procedures Wire all site systems to be incorporated into remote monitoring –MM –E.G.A. (stand-alone units) –Analogue and digital I/O units Set switches –Switch bank1 to #001 –Switch bank2 to off for #1-8 Connect DTI to PC or modem Modem to telephone connection (plant manager)

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Troubleshooting Wire all site systems to be incorporated into remote monitoring –MM –E.G.A. (stand-alone units) –Analogue and digital I/O units Set switches –Switch bank1 to #001 –Switch bank2 to off for #1-8 Connect DTI to PC or modem Modem to telephone connection (plant manager)

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software MODBUS protocol Monitoring and control to the PC Windows based software (winPCDTI) Remote on/off control Set-point adjustments Define alarm conditions Continuous Emissions Monitoring Software (CEMS)

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software MM Units (by ID number)

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software MM Online Data

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software MM Data Logging

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software User-Definable Parameters

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software MM Data Logging

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software Shuffle Sequencing

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software MM Load Index

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software Alarms

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software Alarms

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software WinPCDTI Configuration Modem settings including: - Site details (image/name/contact number/pager number)

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Moxa Serial to Ethernet Convertor

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software WinPCDTI Configuration Password protection Configuration - Com-Port - Serial port/modem - Timeout threshold - Retry Count

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI D.T.I. Software WinPCDTI Configuration

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Analogue I/O module Six 4-20mA inputs Six 4-20mA outputs Digital I/O module 16 line voltage inputs 8 volt free contacts Analogue and Digital I/O Units

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI I/O Modules

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Analog I/O Unit

Analog I/O Data Logging

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Digital I/O Unit

Digital I/O Set-Up

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI C.E.M.S. Continuous Emissions Monitoring Software MM fuel flow metering E.G.A. operational data –Calculations for each fuel used –Stored in database- Logged every x minutes (user definable) ∙Accessible through excel format (.csv) ∙For E.P.A. monitoring –Total emissions as weight or volume ∙O 2, CO 2, CO, H 2 O, NO, N 2 and SO 2 –Net/gross efficiency (%) –Fuel flow per hour and totalised –Total heat input and useful heat input

C.E.M.S. Data

C.E.M.S. Data – Logging

C.E.M.S. Set-Up

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI System Approvals European –CE –TUB –APAVE American –uL –cUL –FM

World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Thank you for listening.