Patrick Thorpe AstralPool UK Ltd

Slides:



Advertisements
Similar presentations
Stairway Construction
Advertisements

Safety in Swimming Pools A public safety issue Colin McCready.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Welcome to Energy efficiency for gas-fired and oil-fired domestic heating and hot water systems Session A: Course introduction.
Optimum Round Pool Instructions. Prepare the pool site Remove all the grass on a surface 2’ wider than the size of the pool Level the ground.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
2013 Top 5 CFO Inspection Concerns Sgt Peter Niedermaier Supervisor of Shooting Clubs and Shooting Ranges Chief Firearms Office of Ontario.
SWIMMING POOL PRESENTATION. GOALS FOR TONIGHT Understand the importance of swimming pool safety Understand recent legislative changes to the Swimming.
BS9990 : 2015 Updates and/or Changes
Checkout of Grassed Waterways Beth E. Clarizia, P.E. Agricultural Engineer.
ArcelorMittal Technotron s.r.o. Expanded Metal – Fliers and Framings November 2008.
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Inspection & Test Overview suite412.
London, 21 May 2014 Alan Brinson A European Residential Sprinkler System Design, Installation and Maintenance Standard.
KSVAS LTD1 WORLD CONGRESS OF STERILIZATION COMBINED MEETING WFHSS / AIOS Small Steam Sterilizers BS EN 1360:2004.
Layers of Protection by Troy Whitfield U.S. Consumer Product Safety Commission These comments are those of the CPSC staff, and have not been reviewed or.
Amendment to GPDO Householder Permitted Development.
Climbing the Ladder to Safety
SAA 2004 / 2005 update.. What have we been up to? What has the SAA been up to in 2004? Launched Extended Range Nitrox Diver Gas Blender Course approval.
Hydraulics Engineering
The Equality Act 2010 and Accessibility of lifts for disabled users.
Unit 206: Domestic hot water systems
STEAM CONDENSERS.
1 Pool Barriers Presented by: The Office of Building Code Compliance.
Pool Safety By Dan Finerfrock. Credibility Lifeguard for 5 years Pool Operator certified Member of pool for 15 years CPR and First Aid certified.
Floating Head Heat Exchanger
MINIMUM ACCEPTABLE LEVELS OF SAFETY & RELIABILITY
2004 National Pool Fencing Forum. Hassall, I. (1989) Thirty-six consecutive under 5 year old domestic swimming pool drownings. Australian Paediatric Journal,
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
SPATA Regional Meeting at Cannings, Exeter Tuesday 3 rd November 2015.
Electrical Safety Authority
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
DESIGN OF SINGLY REINFORCED BEAM
1Fall FALL PROTECTION. 2Fall CONTENTS  Introduction  Purpose  Same Level Falls  Lower Level Falls  Fall Prevention  Summary.
TRUMAN MIDDLE SCHOOL Presented by Counsilman ▪ Hunsaker Facility Audit.
Outcome 4 (part 4) Install and test above ground systems Unit 209: Drainage systems.
Resolving Common Problems with Developing Louver Catalogs.
Unit 209: Drainage systems
Name ____________Class_____ Date______ Area of Rectangles The ________ _ of a figure is the amount of surface it covers. It is measured in ________ __.
TEHA PANHANDLE MEETING – JUNE 2017 POOL SAFETY Speaker: Gregg Olberts
Trench Hazards Introduce the module. Trenching & Excavations Continuing Education Third Quarter 2017 Session 3.
Department of Permits, Licenses, and Inspections
WJEC Past Paper Questions (with answers)
SoUTh Shore Pool Supply
FIXED LADDER SAFETY REVIEW
MDX-R3 INSTALLATION PROCESS ADJUSTABLE CONCRETE POOLS
How to design a safe Domestic Trampoline in EU
Direct lines - problem in Bulgaria
MDX-R3 INSTALLATION PROCESS NON-ADJUSTABLE CONCRETE POOLS
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Direct lines - problem in Bulgaria
Stainless Steel Mesh Suppliers in UAE
OWNER’S OPERATING MANUAL for ARCORAIL HANDRAIL SYSTEMS
The AfriDev Pump COST: $10,700
Order of Engineers and Architects New Lebanese Standards Related to LIFTS NL EN 81standards Habib Srour.
Robin Holdsworth - City of Canning
ME444 ENGINEERING PIPING SYSTEM DESIGN
Cold water supply and Treatment
Hot Water Systems Cylinders and Systems.
FALL PROTECTION.
Cisterns and Insulation
Floating Head Heat Exchanger
2 Days National Workshop on “National Building Code of India 2016 ”
February 2019.
About us The ZGP groups owns three hot dip galvanizing plants. Company's firms have the following facilities: The company has a total area of ​​
The MobileIron® Threat Detection difference:
Resolving Common Problems with Developing Louver Catalogs
Supply, Delivery and Installation of 7000L Heavy-duty industrial steel as per specifications, Construction of Metal Fence as per specifications at General.
Communication Power & Security Limited
Presentation transcript:

Patrick Thorpe AstralPool UK Ltd European Standards Patrick Thorpe AstralPool UK Ltd

European Standards for Domestic Pools TC402 Domestic Pool Standards. Split into 2 sections: WG1 – Pool Construction & Installation. WG1 is now BS EN 16582– 1/2/3 Part 1 - General Requirement including safety and test methods Part 2 -Specific requirements for in-ground pools Part 3- Specific requirements for above ground pools WG2 – Pool Water Filtration, Circulation & Treatment. WG2 is now BS EN 16713-1/2/3 Part 1 Filtration Systems Part 2 Circulation Systems Part 3 Water Treatment Requirements

European Standards for Domestic Pools WG1 is complete and should come into effect before the end of 2015 as BS EN 16582. WG2 should come into effect 2016 as BS EN 16713. Based on much of SPATA standards.

European Standards for Domestic Pools Changes from SPATA & Commercial Standards: Permissible Openings – applicable only over 500mm depth. - Finger & toe <8mm or >25mm Head & neck <110mm to > 230mm When ranges 25mm to 110mm are used for construction reasons, installer to alert their customer of a potential risk of entrapment (discuss overflow channels) Velocities for Main Drains – now 0.5m/s. A minimum of 2 balanced drains Main drains can be 1m apart (not 2m). Nearest points of the perimeters. Refurbishment with 1 grille - increase size of drain to 1m² fix an anti-entrapment grille with peripheral suction and high dome shall be at least 10% of main dimension any drain where one user cannot cover 50% of opening Double width top tread for pool ladders is recommended.

European Standards for Domestic Pools Changes from SPATA & Commercial Standards: All Swimming pools should be provided with: Warning Signs – “Children must be supervised at all times” “No diving” Instruct client to fix signs within 2,000mm of the pool in a prominent visible position

Revised Acceptable Water Losses Pools should be built water tight Pools should be water tight to one of the classes listed below: This is to be pointed out in point of sale material SPATA will anticipate ‘W0’ or ‘W1’, but a minimum may be ‘W2’ (for outdoor pools only). Discuss how to inform the end user Tightness Class Maximum leakage mm per day or litres / m2 W0 W1 1 W2 2 W3 3

European Standards for Domestic Pools Changes from SPATA & Commercial Standards: Accessibility Secure the means of access or Install a protection device and Keep children under constant supervision Protection devices include: Fencing, Safety Covers, Enclosures, Alarms Note: securing the boundary of the property may be acceptable Pool shell life span will be 10 years (what guarantees)? Partially or fully sunken Above Ground Pools will be treated as In-ground Building tolerances less onerous. Pumps can be connected with flexible joints “Shall” means “must” and “should” means “recommended”.

Keeping up with Legislation SPATA is up to date with ever changing legislation. We are involved in both the creation of legislation / standards and their compliance. We lobby alongside BSI on your behalf against onerous requirements that are impractical. We will continue to keep you informed of developments.

Any Questions?