SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.

Slides:



Advertisements
Similar presentations
Telecommunication Rooms
Advertisements

Chapter 3: Planning a Network Upgrade
Telecom Cabling Grounding and bonding.
1 Structured Backbone Design of Computer Networks.
CIT 470: Advanced Network and System Administration
TIA-1005 (Proposed by TR-42.9) Industrial Cabling Standard Pete Lockhart Anixter Manufacturing IT Forum Cleveland, Ohio May 20-21, 2008.
Infrastructure and components. Cable The cable and components used in structured cabling systems is defined in the standards –EIA/TIA 568 x There are.
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
1 25\10\2010 Unit-V Connecting LANs Unit – 5 Connecting DevicesConnecting Devices Backbone NetworksBackbone Networks Virtual LANsVirtual LANs.
Damian Gordon.  When we hook up computers together using data communication facilities, we call this a computer network.
Network Topologies. Point-to-Point Topology Point-to-point (PTP) topology connects two nodes directly together. The following examples are pure point.
Structured Cabling Overview
1.1 Chapter 1 Introduction Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
1 Wide Area Network. 2 What is a WAN? A wide area network (WAN ) is a data communications network that covers a relatively broad geographic area and that.
ASHIMA KALRA.  COMPUTER NETWORK  Local Area Network (LAN) Local Area Network (LAN)  Metropolitan Area Network(MAN) Metropolitan Area Network(MAN) 
Networks A network is a collection of computers and devices connected together via communications devices and transmission media Advantages of a network.
The Public Network Chapter 4. Objectives In this chapter, you will learn to: Explain, in general terms, the structure of the public telephone network.
Information Technology Lecture No 3 By: Khurram Shahid.
Basic LAN techniques IN common with all other computer based systems networks require both HARDWARE and SOFTWARE to function. Networks are often explained.
Signamax Structured Cabling Seminar. INTRODUCTION.
The Public Network Chapter 4. Objectives In this chapter, you will learn to: Explain, in general terms, the structure of the public telephone network.
Network Topologies Lecturer: Hyder R. Hamandi. Network Topologies Physical topologies describe how the cables are run in the network A topology is a way.
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
1 Guide to Network Cabling Fundamentals Chapter 5.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
CABLING SYSTEM BACKBONE SUBSYSTEM.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
Chapter 21 Topologies Chapter 2. 2 Chapter Objectives Explain the different topologies Explain the structure of various topologies Compare different topologies.
Network Topology
The McGraw- AS Computing LAN Topologies. The McGraw- Categories of LAN Topology.
4 - 1 Copyright © 2006, The McGraw-Hill Companies, Inc. All rights reserved. Computer Software Chapter 4.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Jim Van Dyke Network Engineering & Technology Section The UCAR Physical Network Infrastructure or Why Bother to Do It Right? Presented By: James R. Van.
CABLING SYSTEM ADMINISTRATION. Administration Concept.
SIGNAMAX WARRANTY SYSTEM. Signamax Warranty Types Signamax Connectivity Systems offers its customers a versatile system of component and system warranties.
Signamax™ Cabling System Design Principles & Installation Practices Revision A.
Chapter2 Networking Fundamentals
Summary - Part 2 - Objectives The purpose of this basic IP technology training is to explain video over IP network. This training describes how video can.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
Signamax™ Cabling System Review Revision E. INTRODUCTION.
 Physical arrangement of devices in a network  Common types: › Ring › Bus › Star › Tree.
COMPUTER NETWORK CREATED BY:- PALASH SACHAN. CONTENTS INTRODUCTION COMPUTER NETWORK TYPES OF NETWORK CLASSIFICATION OF NETWORK ARCHITECTURE NETWORK TOPOLOGY.
Gary Marret, RCDD WHAT IS ETHERNET? WHAT IS ETHERNET? WHAT IS ETHERNET/IP? WHAT IS ETHERNET/IP? ETHERNET HARDWARE? ETHERNET HARDWARE? HOW DO I CABLE.
BACKBONE SUBSYSTEM. CABLING SYSTEM Backbone Subsystem The Backbone cabling subsystem is based on cabling segments, which link such connection centers.
TELECOMMUNICATIONS SPACES. WORK AREA WA Work Area Work Area (WA) Telecommunications Outlet (TO) Horizontal subsystem cables Equipment and patch cords.
TELECOMMUNICATIONS SPACES
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
Introduction to Networks Mr. Grimming. Types of Networks Wide Area Network (WAN) Cover large geographic area Nodes connected by coaxial cable, microwave.
Chapter 1 Introduction Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. 1.#
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
A local area network (LAN) is a group of computers and associated devices that share a common communications line or wireless link. Typically, connected.
Copyright © 2006 Heathkit Company, Inc. All Rights Reserved Introduction to Networking Technologies Introduction to Networking.
 Introduction to Wide Area Networks 2 nd semester
Introduction Chapter 1. Introduction  A computer network is two or more computers connected together so they can communicate with one another.  Two.
Chapter Seven Network Topology [tə'p ɒ ləd ʒɪ ]. In networking, the term “topology” refers to the layout of connected devices on a network. This article.
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
Paula Valdez 10MO ALFA BASIC CONCEPTS OF NETWORK.
NETWORKING TOPOLOGIES Ms. Edwards. Table of Contents Monday ◦ What is a network topology? ◦ BUS -what it is? -how it functions? ◦ STAR -what it is? -how.
Data centre network map
Computer Network Collection of computers and devices connected by communications channels that facilitates communications among users and allows users.
INTRODUCTION TO NETWORK CABLING
Wide Area Network.
Horizontal and Back Bone Cabling
Computer Systems Department.  Introduction  Course Objectives  Grading Policy  Lab Policy  Structured Cabling.
Chapter 1 Introduction Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Presentation transcript:

SIGNAMAX CABLING SYSTEM

Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements and recommendations of the international and national standards for telecommunications cabling within a commercial building and between buildings in a campus environment These rules specify cabling topology, transmission media, cabling distances, and telecommunications outlet configurations

Signamax Cabling System Rules given by the Manual are intended to implement a telecommunications cabling designed to support a wide range of different commercial building sites and applications (e.g., voice, data, text, video, and image) Typically, this range includes sites with a geographical extent from 3,000 m (about 10,000 ft), up to 1,000,000 m 2 (about 10,000,000 ft 2 ) of office space, and with a population of up to 50,000 individual users

Signamax Cabling System Work Area (WA) Telecommunications Outlet (TO) BMS field devices Video surveillance system devices Cabling system transmission media Equipment and patch cords Cross-connect connecting hardware Cross-connect

Cabling Structure Generic telecommunications cabling system structure includes the following subsystems and additional elements: –Horizontal subsystem –Backbone subsystem –Work Area –Telecommunications Room –Equipment Room –Entrance Facility –Administration

Functional elements Generic telecommunications cabling system consists of the following functional elements: –Main Cross-connect (MC) –Level I Backbone subsystem cable –Intermediate Cross-connect (IC) –Level II Backbone subsystem cable –Horizontal Cross-connect (HC) –Horizontal subsystem cable –Consolidation Point (CP) –Multiuser Telecommunications Outlet Assembly (MuTOA or MuTO) –Telecommunications Outlet (TO) Groups of these functional elements are connected together to form cabling subsystems

INTERBUILDING (CAMPUS) BACKBONE SUBSYSTEM BUILDING B IC ER/EF HC TR HC TR TO WA HC TR IC ER/EF HC TR HC TR TO WA BUILDING C IC ER/EF HC TR HC TR HC TR TO WA BUILDING D HC TR IC ER/EF HC TR HC TR TO WA BUILDING E HC TR TO WA INTRABUILDING BACKBONE SUBSYSTEM HORIZONTAL SUBSYSTEM SERVICE ENTRANCE LEVEL II BUILDING A IC ER LEVEL I HC TR HC TR DP EF MC ER/EF ER Cabling Structure

Structure alphabet soup MC – Main Cross-connect IC – Intermediate Cross-connect HC – Horizontal Cross-connect TO – Telecommunications Outlet/connector MuTOA – Multi-user Telecommunications Outlet Assembly WA – Work Area TR – Telecommunications Room ER – Equipment Room EF – Entrance Facility CP – Consolidation Point DP – Demarcation Point |X| – Cross-connect I – Level I Backbone subsystem II – Level II Backbone subsystem

Subsystems Signamax Cabling System schemes consist of three cabling subsystems: –Level I Backbone –Level II Backbone –Horizontal cabling The cabling subsystems are connected together to create a generic cabling structure as shown on the next slide. The cross-connects provide the means to configure the cabling to support different topologies like bus, star and ring

Subsystems

Level I Backbone Subsystem The level I Backbone cabling subsystem extends from the Main Cross-connect to the Intermediate Cross-connect(s) usually located in separate buildings

Level I Backbone Subsystem The level I Backbone cabling subsystem includes –the Level I Backbone cables; –jumpers and patch cords in the Main Cross-connect; –the connecting hardware on which the Level I Backbone cables are terminated (at both the Main and Intermediate Cross- connects)

Level I Backbone Subsystem Although equipment cables are included in a Channel, they are not considered part of the cabling subsystem because they are application specific

Level I Backbone Subsystem Where the Intermediate Cross-connect does not exist, the Level I Backbone cabling subsystem extends from the Main Cross-connect to the Horizontal Cross-connect

Level I Backbone Subsystem The Level I Backbone cable may also interconnect Intermediate Cross-connects. Such connections shall be in addition to those required for the basic hierarchical topology

Level II Backbone Subsystem The Level II Backbone cabling subsystem extends from Intermediate Cross-connect(s) to the Horizontal Cross- connect(s)

Level II Backbone Subsystem The Level II Backbone cabling subsystem includes –the Level II Backbone cables; –jumpers and patch cords in the Intermediate Cross-connect; –the connecting hardware on which the Level II Backbone cables are terminated (at both the Intermediate and Horizontal Cross- connects)

Level II Backbone Subsystem Although equipment cables are included in a Channel, they are not considered part of the cabling subsystem because they are application specific

Level II Backbone Subsystem The Level II Backbone cable may also interconnect Horizontal Cross-connects However, such connections shall be for back-up and in addition to those required for the basic hierarchical topology

Horizontal Subsystem The Horizontal cabling subsystem extends from a Horizontal Cross-connect to the Telecommunications Outlet(s) connected to it

Horizontal Subsystem The Horizontal cabling subsystem includes –the Horizontal subsystem cables –any cross-connections to application specific equipment at Horizontal Cross-connect –the mechanical termination of the Horizontal subsystem cables at the Horizontal Cross-connect including the connecting hardware –the mechanical termination of the Horizontal subsystem cables at the Telecommunications Outlet –a Consolidation Point (optional)

Horizontal Subsystem Although Work Area cords and equipment cables are included in a Channel they are not part of the cabling subsystem because they are application specific

Horizontal Subsystem Horizontal cables shall be continuous from the Horizontal Cross-connect to the Telecommunications Outlets unless a Consolidation Point is installed

Interconnection of Subsystems Hierarchical structure

Interconnection of Subsystems Centralized structure

Interconnection of Subsystems Cross-connects shall be located in –Telecommunications Rooms –Equipment Rooms –Entrance Facilities

Interfaces

Channel & Permanent Link The Signamax Cabling System consist of Channels and Permanent Links. The transmission performance of structured cabling between specific interfaces is detailed in terms of the Channel and the Permanent Link

Channel & Permanent Link The Channel is the transmission path between active equipment and the terminal equipment. For the purposes of testing, the Channel does not include the mated connection at the IT equipment.

Channel & Permanent Link The Permanent Link is the transmission path between the mated connectors located at the ends of the installed cable in a cabling subsystem. The Permanent Link contains the mated connections located at the ends of the installed cabling

Dimensioning & configuring The number and type of subsystems that are part of a generic cabling implementation depends on the geography and size of the campus or building, as well as on the user strategy. Generally there would be –one Main Cross-connect per campus –one Intermediate Cross-connect per building –one Horizontal Cross-connect per floor If the premises have only a single building, which is small enough to be served by a single Horizontal Cross-connect, a level I Backbone cabling subsystem is not required

Dimensioning & configuring Cross-connects should be located such that the resulting cable lengths comply with the Channel performance requirements set forth in the –“ HORIZONTAL SUBSYSTEM ” and –“ BACKBONE SUBSYSTEM ” sections The maximum Channel lengths shown on the next slide should be observed

Dimensioning & configuring Maximum allowable Channel lengths in the cabling subsystems: The distances given are for the total backbone Channel length, including backbone cable, patch cords or jumpers, and equipment cable Channel Type Distance, m (ft) Horizontal subsystem (HC – TO)100 (328) Level II Backbone subsystem (IC – HC)300 (984) Level I + II Backbone subsystem (MC – HC) 2,000 (6,562) 5,000 (16,404)

Dimensioning & configuring Not all applications are supported over the maximum lengths shown in the previous table using a single cable type The maximum supportable distances are application and media dependent To determine the maximum acceptable Channel length refer to standards for specific telecommunications applications Installer companies are advised to consult the specific standards associated with the planned service, or equipment manufacturers to determine the suitability of the cabling described herein for specific applications

Dimensioning & configuring There should be at least one Horizontal Cross-connect for every 1,000 m 2 (10,000 ft 2 ) of floor space reserved for offices If a floor area is over 1,000 m 2 (10,000 ft 2 ), additional Horizontal Cross-connects may be required to provide more effective service to the Work Area

Dimensioning & configuring A minimum of one Horizontal Cross-connect should be provided for every floor. If a floor contains few people (e.g. a lobby), this floor may be served from the Horizontal Cross- connect located on an adjacent floor. If a floor is sparsely populated (e.g. a lobby), it is permissible to serve this floor from the Horizontal Cross-connects located on an adjacent floor

Dimensioning & configuring The functions of multiple cross-connects may be combined

Dimensioning & configuring In some conditions, for example for reasons of security or reliability, redundancy may be built into a cabling design. This might form the basis for the design of generic cabling for a building, providing some protection against such hazards as fire damage or the failure of the public network feeder cable