Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No.

Slides:



Advertisements
Similar presentations
Goyen Series 4 Reverse Pulse Jet Pulse Valve.
Advertisements

(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No.
ICAM50x Series – Intrinsically Safe Digital Cameras Copyright Extronics Ltd iCAM50x Series Intrinsically Safe Digital Cameras for Hazardous Areas.
Myers Hubs Crouse-Hinds Training Module.
Severe Service Metal Seated Ball Valves
Sales Training Outline 2006 Jeff Roye Product Manager Liquid Tight Strain Reliefs 35 Royal Road Flemington, NJ
Mechanical AST5300 is a wet / wet differential pressure transmitter Compatible with liquids or gases on both the high pressure and low pressure process.
Explosion Proof Cameras What is Explosion Proof (EX)? Electric Powered Industrial Equipment, used in areas containing explosive or flammable materials,
EKAS Power cable and conductor terminations UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO1B Chris Hungerford.
External nut type series 43
You Can Measure the Benefits… Training Course Introduction to SmartScan.
For the interconnection of pneumatic components and systems
1. Presentation Overview  Solar Industry Overview  Intro into Solar Photovoltaics  Types of PV Systems  Solar Product Offering –Solar Combiner Boxes.
Ultra-Lightweight Stainless Steel Micro-Filament EMI/RFI Braid.
Electrical Installation II
Moeller GmbH page - 1 ATEX. IB ATEX GB Refer to protection notice ISO Moeller GmbH Page - 2 ATEX - HMI-PLC Introduction What is ATEX, and.
You can Measure the Benefits… Training Course SolidScan’s products.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
© BA Electrical Machines - 1 M3000 Ex-motors August 2002 M3000 Low Voltage Motors for Hazardous Areas.
E VERY L IFE H AS A P URPOSE… Ultima ® XL/XT Gas Monitors.
You Can Measure the Benefits… Solid Applied Technologies.
Automation and Drives A&D SD SM1, Hr. Mölter /62 Explosionsschutz_En_02_2004.ppt Standard Drives 3.2Classification of gases and vapors in explosion.
Technical Features. 2 Highest switching distance( 가장 긴 센싱거리 자랑 ) Because of the novel patented coil technology, sensors feature a switching distance that.
Hall D Integration Status GlueX Collaboration Meeting Indiana University, Ravi Anumagalla.
1 Name | Confidential Date Center line content EXPLOSION-PROOF ENCLOSURE MARKET INTRODUCTION PRESENTATION.
Temperature Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
TAKE ‘N’ TRAIN ZONEX™ NON-METALLIC TERMINAL ENCLOSURE.
Product Overview. Hazardous & Industrial Enclosures ATEX & IECEx Compliant.
Ultrasonic Early Kick Detection (EKD) System
UL Recognition CSA Approval Mechanical Protection Tubing (MPT) and Fittings UL1696 2nd Edition - CSA C22.2 No th Edition.
Ultrasonic High-Pressure Full-Bore Return Flow Meter IBJ Technology Ingenieurbüro Jäger 1 Ultrasonic Mud Flow Meter.
DESIGN AND DEVELOPMENT OF GRINDING ATTACHMENT ON LATHE MACHINE
OELD - Optima Excel Local Display
Hazardous Area Timefiller Pt 2
Asahi/America Electric Actuators
MKTG 2016.
PRO-FLO X™ 25 MM (1”) ADVANCED™ METAL NATURAL GAS POWERED PUMP
Extrima ex-certified Hydrogen Leak detector
Hazardous Area Environments
MKTG 2016.
CLIC Common RF-girder study
EET 422 EMC & COMPLIANCE ENGINEERING
Top Quality Stop Valves Manufactured by Maniks
a Certificate of Conformity
Ron Sinclair Managing Director – Baseefa
IECEx Industry Seminar Integrating IECEx and ATEX for Europe
Electrical Insulation
THUM Adapter Impact on Hazardous Area Classification
Louis Poulsen WeeBee Opal LED Description - Luminaire type
EPB 5672 High precision collet chucks
Asahi/America Electric Actuators
JAQUET Products for Railway Applications
NEMA RV 3 Application & Installation Guidelines For Flexible & Liquid Tight Flexible Metal Conduits
MKTG 2016.
ZUMTOBEL KXB 2/36W EVG ZONE 2/ Description
For the interconnection of pneumatic components and systems
Louis Poulsen Malmö Trio Pendant Description - Luminaire type
Valves according to ISO Standard
Louis Poulsen PH Artichoke Description - Luminaire type
Louis Poulsen PH Artichoke Description - Luminaire type
STEEL PLATES.
Technical Features.
ZUMTOBEL KXB 1/58W EVG ZONE 2/22 DV Description
Day 2 Training - Technical
Innovative Natural Gas Calorimeter GasCVD
Louis Poulsen PH 3/2 Pendant 8410 Description - Luminaire type
Connection Types & Sizes BSPT or NPT threaded
Louis Poulsen Reduced Description - Luminaire type
Plastic Pipe and Fittings Association
Presentation transcript:

Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FA/CThread 16 – 3/8” HAM*0304U M16M HAA*0304U3/8”½” – ½” HAM*0404U M HAA*0404U½” – ¾” HAM*0505U SS 37.0 M HAA*0505U3/4”¾” – 1” HAM*0606U SS 45.0 M HAA*0606U1” – 1 ¼” HAM*0707U M HAA*0707U1 ¼” – 1 ½” HAM*0808U M HAA*0808U1 ½” – 2” HAM*0909U SS 76.0 M HAA*0909U2” 81.0 Description- Group 1 Flameproof Barrier Gland For use with all conduit types via female threaded entry IP66, -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use- Groups I and II Zones 1, 2, 21 and 22 Class I Div I BCD (Rigid Conduit Only) Class II Div I EFG Exde I Mb Exde IIC Gb Extb IIIC Db Material- Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits- Suitable for all conduits including: Rigid - Metallic - Non Metallic Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC :2007 Ed 5, IEC :2007 Ed 6, IEC :2007 Ed 4, IEC :2008 Ed 1 EN :2009 EN :2007 EN :2007 EN :2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland Body90° ElbowMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FConduit 16 – 3/8” HAM*0304E mm M HAA*0304E½” 20 – ½” HAM*0404E mm M HAA*0404E½” 25 – ¾” HAM*0505E SS 25mm M HAA*0505E¾” 32 – 1” HAM*0606E SS 32mm M HAA*0606E1” 40 – 1 ¼” HAM*0707E mm M HAA*0707E1 ¼” 50 – 1 ½” HAM*0808E mm M HAA*0808E1 ½” 63 – 2” HAM*0909E SS 63mm M HAA*0909E2” Description- Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits IP66 -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use- Groups I and II Zones 1, 2, 21 and 22 Class I Div I BCD (Rigid Conduit Only) Class II Div I EFG Exde I Mb Exde IIC Gb Extd IIIC Db Material- Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits- EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC :2007 Ed 5, IEC :2007 Ed 6, IEC :2007 Ed 4, IEC :2008 Ed 1 EN :2009 EN :2007 EN :2007 EN :2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FA/C 16 – 3/8” HAM*0304G M HAA*0304G1½” 20 – ½” HAM*0404G M HAA*0404G1½” 25 – ¾” HAM*0505G SS 37.0 M HAA*0505G1¾” 32 – 1” HAM*0606G SS 45.0 M HAA*0606G11” 40 – 1 ¼” HAM*0707G M HAA*0707G11 ¼” 50 – 1 ½” HAM*0808G M HAA*0808G11 ½” 63 – 2” HAM*0909G SS 76.0 M HAA*0909G12” Description- Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits IP66, -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use- Group I and II Zones 1, 2, 21 & 22 Class I Div II ABCD Class II Div I EFG Exde I Mb Exde IIC Gb Extb IIIC Db Material- Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits- EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC :2007 Ed 5, IEC :2007 Ed 6, IEC :2007 Ed 4, IEC :2008 Ed 1 EN :2009 EN :2007 EN :2007 EN :2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

Universal Gland Flameproof System PART No.BODY A/F ‘A’ THREAD ‘B’ MIN BORE ‘C’ ‘D’‘E’NUT A/F ‘F’ EXPQM M EXPQM M EXPQM M EXPQM M EXPQM M EXPQM M EXPQA ½” NPT EXPQA ½” NPT EXPQA ¾” NPT EXPQA ” NPT EXPQA ¼” NPT EXPQA ½” NPT Description- For use with standard weight braided antistatic conduit EXB, Material- Body and Nut : Nickel plated Brass Seals: Silicone Intended Use- An electrically discharging cable protection system. This system protects electrical cables and wires from mechanical damage and UV radiation Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC Compatible Conduits- EXB Antistatic Polyamide 12 Conduit Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC , IEC , EN , EN , IEC IEC EN & EN Certifications- ATEX IECEx BASEEFA ATEX X IECEx BAS X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12

Universal Gland Flameproof System PART No.BODY A/F ‘A’ THREAD ‘B’ MIN BORE ‘C’ ‘D’‘E’NUT A/F ‘F’ EXBQM M EXBQM M EXBQM M EXBQM M EXBQM M EXBQM M EXBQA ½” NPT EXBQA ½” NPT EXBQA ¾” NPT EXBQA ” NPT EXBQA ¼” NPT EXBQA ½” NPT Description- For use with standard weight braided antistatic conduit EXBB, this system gives additional wear and EMC Protection Material- Body, Nut and Internal components: Nickel plated Brass Seals: Silicone Intended Use- An electrically discharging cable protection system. This system protects electrical cables and wires from mechanical damage and UV radiation Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC Compatible Conduits- EXBB Stainless Steel Overbraided Antistatic Polyamide 12 Conduit Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC , IEC , EN , EN , IEC IEC EN & EN Certifications- ATEX IECEx BASEEFA ATEX X IECEx BAS X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12