Presentation is loading. Please wait.

Goyen Series 4 Reverse Pulse Jet Pulse Valve.

Similar presentations


Presentation on theme: "Goyen Series 4 Reverse Pulse Jet Pulse Valve."— Presentation transcript:

1 Goyen Series 4 Reverse Pulse Jet Pulse Valve

2 4 Series Overview....

3 Application The extremely rapid response, and very high flow rate delivered by the 4 Series diaphragm valves makes this product especially suitable for reverse pulse jet filter cleaning. This high performance valve may be used for new dust collector builds or to replace existing ¾” and 1” valves in a dust collector refurbishment.

4 Application Typical examples: fabric filters pleated filters
Panel filters Manufacturing Power generation Mining Resources Steel and cement

5 4 Series Features

6 No more spring failures!
Shockwave diaphragm Integrated spring. Proprietary engineering thermoplastic elastomer blend for consistent performance throughout the temperature and pressure range. Environmentally endurance tested at the extremes. No spring failures! 1 Million Cycles guaranteed!

7 The coupling method of your choice
Available with ¾” and 1” ports Threaded The classic Goyen dresser nut coupling design. FS - Flange and Slide Seal Threaded connections. Nitrile or viton seals. FS Dresser nut

8 Which repair kit? No problem!
Integral kit markings The 4 Series valve is marked with the appropriate diaphragm replacement kit part number. No more searching catalogues or calling to find the right kit. Simple!

9 2-in-1: Integral or remote solenoid.
Using the RCA3PV Series, or RCA3DM Series pilots, the 4 Series valves can be easily configured for integral piloting. RCA3PV: DIN connections, ATEX options, CE, Low Cost. RCA3DM: Goyen Q Coil voltage and connection type range with CSA* RCA3PV RCA3DM * CSA from June 15, 2012

10 4 Series quality

11 QUALITY Designed to perform! 100% Performance pressure & tested across
leak tested. Performance tested across pressure range QUALITY ISO9001 Design & Manufacture Environmentally Tested at -40ºC to 82ºC (Shockwave) Made in Australia

12 Quality starts with Design...
Designed to perform! Quality starts with Design... 100% pressure & leak tested. Performance tested across pressure range 15 – 40% higher peak pressure than equivalent older ‘2’ Series models. Consistent pulse profile, regardless of pressure. QUALITY ISO9001 Design & Manufacture Environmentally Tested at -40ºC to 82ºC (Shockwave) Made in Australia

13 ... And then includes execution.
Designed to perform! ... And then includes execution. 100% pressure & leak tested. Performance tested across pressure range World class manufacturing facility, Quality Systems certified and audited to international standards for design and manufacture. Each valve fully checked for operation and sealing performance. QUALITY ISO9001 Design & Manufacture Environmentally Tested at -40ºC to 82ºC (Shockwave) Made in Australia

14 Dimensions RCAC25 & RCAC20 models
4 Series Dimensions RCAC25 & RCAC20 models

15 Dimensions in mm [inches]
RCAC25DD4: RCAC20DD4: Dimensions in mm [inches]

16 Dimensions in mm [inches]
RCAC25T4: RCAC20T4: RCAC20ST4: Dimensions in mm [inches]

17 Dimensions in mm [inches]
RCAC25FS4: RCAC20FS4: Dimensions in mm [inches]

18 Dimensions rca3pv & rca3dm pilot modules
4 Series Dimensions rca3pv & rca3dm pilot modules

19 Dimensions in mm [inches]
RCA3PV RCA3DM Dimensions in mm [inches]

20 4 Series Performance

21 Kv and Cv values

22 Installation requirements
4 Series Installation requirements

23 Operating Conditions Metric US/Imperial -40ºC to 82ºC -40ºF to 180ºF
Supply compressed air pressure range 0.3 to 8.6 Bar 4.35 to PSI Compressed air temperature (Shockwave diaphragms) -40ºC to 82ºC -40ºF to 180ºF (Viton diaphragms) -40ºC to 232ºC -40ºF to 450ºF Media type Air or inert gases only. Remote pilot connections Minimum pilot tube bore: 4mm (0.16”) Maximum length: 2m (79”)

24 How to order RCAC25 & RCAC20 models
4 Series How to order RCAC25 & RCAC20 models

25 The ‘4’ means this is a fourth generation pulse jet valve.
¾” Valves RCAC20 __ __ __ __ Diaphragm type: 1 – Viton 2 – Shockwave Pilot Port : 0 – NPT Thread 1 – Rc 2 – G Pilot Port : 0 – 1/8” Size 1 – 1/4” Inlet/Outlet style: T4 – Threaded ST4 – Stub Thread DD4 – Dresser nut FS4 – Flange in/ Slide Seal out The ‘4’ means this is a fourth generation pulse jet valve.

26 The ‘4’ means this is a fourth generation pulse jet valve.
1” Valves RCAC25 __ __ __ __ Diaphragm type: 1 – Viton 2 – Shockwave Pilot Port : 0 – NPT Thread 1 – Rc 2 – G Pilot Port : 0 – 1/8” Size 1 – 1/4” Inlet/Outlet style: T4 – Threaded DD4 – Dresser nut FS4 – Flange in/ Slide Seal out The ‘4’ means this is a fourth generation pulse jet valve.

27 How to order Pilot modules
4 Series How to order Pilot modules

28 RCA3PV integral pilot:

29 RCA3DM integral pilot:

30 RCA3DM solenoid choices:

31 RCAC25DD4 Series servicing

32 Repair kit details Diaphragm replacement kit numbers are marked on the diaphragm, visible before disassembly.

33 Shockwave assembly Viton assembly

34 Valve & Pilot service kit codes
Valve model Shockwave Viton Nitrile RCAC20T4 RCAC20ST4 K2034 K2033 N/A RCAC20DD4 DRESSER SEAL KIT K2009 K2008 RCAC20FS4 OUTLET SEAL G G690338 RCAC25T4 K2546 K2551 RCAC25DD4 K2507 K2508 RCAC25FS4 G G690763 RCA3DM N/S K0384 K0380

35 RCAC25DD4 Series Approvals

36 European Directive (CE)
Approvals Under the treaty of establishing the European Economic Community, the council of European Communities adopted into law a series of directives to harmonize technical standards. The 4 series valves are controlled by When used in combination with Goyen or Mecair solenoids, these valves are also controlled by The Goyen 4 Series valves and its compatible Goyen solenoid pilots comply with these directives, and bear the CE approval mark on the solenoid and/or valve cover. Council Directive # Machinery 89/392/EEC PED 97/23/EC European Directive (CE) Council Directive # EMC 89/336/EEC Low Voltage 72/23/EEC

37 Approvals Hazardous areas
The Goyen 4 series may be used with any of the Goyen or Mecair remote pilot enclosures. These enclosures include products with UL, CSA, and ATEX certifications to meet the applications of CSA: Class I, Group D Class II, Groups E, F, G UL: ATEX: II 2 G D (Ex d IIB T3 Gb) II 2 G D (Ex d IIB T6 Gb) Please refer to the Goyen or Mecair literature for further information on these enclosures. Hazardous areas

38 Goyen Series 4 Reverse Pulse Jet Pulse Valve