What’s new?. …including “fixes” made to the code in the 2012 Supplement August, 2012 www.floridabuilding.org/fbc/links_to_code_resources.html.

Slides:



Advertisements
Similar presentations
SEATTLE ENERGY CODE ENFORCEMENT PROCEDURES: PLAN REVIEW AND INSPECTION John Hogan, A.I.A., P.E. Seattle Department of Planning and Development 700 Fifth.
Advertisements

BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
U.S. Department of Energy Building Energy Codes Program
eQuest Quick Energy Simulation Tool
ENERGY STAR Multifamily High Rise Program
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Commercial Mechanical Requirements
Tas seminar/demonstration on Part L 2006 of the Building Regulations Presented by Alan Jones EDSL February
“Do not take anyone’s advice as to how this building should be assembled.”
2009 Washington State Energy Code Residential Sections
Residential Provisions of the 2012 International Energy Conservation Code July 2011 PNNL-SA
Manitoba Energy Code for Buildings 2013
2009 versus 2012 IECC Maryland Affordable Housing Coalition June 26th, 2012.
The Three Tiered Philosophy
Energy Square 1111 “O” Street, Suite 223 Lincoln, Nebraska Website: Phone:
Effective March 15, New Base Code 2009 International Energy Conservation Code (IECC) Florida specifics are integrated into the document The biggest.
Passive Heating and Cooling
2004 Florida Building Code, Mechanical/Energy Technical Core Summary (1 hour) June 2004.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
West Virginia's residential building code is mandatory statewide; however, adoption by jurisdictions is voluntary. The 2013 West Virginia Legislature.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Building Australia’s Future Energy Efficiency Introductory Awareness Training AUSTRALIAN Greenhouse Office Supported by: Step by Step Application of BCA.
Presented by: Energy Systems Laboratory (ESL) Texas A&M University Funded by: State Energy Conservation Office (SECO) US Department of Energy (DOE) The.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
THE IMPACT OF STATE LEVEL BUILDING CODES ON RESIDENTIAL ELECTRICITY CONSUMPTION Anin Aroonruengsawat UC Berkeley, ARE Maximilian Auffhammer UC Berkeley,
Free Software for Energy Code Compliance Free Software for Energy Code Compliance Presented By: Mustafa Abdul Geleel Hussien By: Evan H. Shu, FAIA Web.
Service Calculations One and Two Family And Multi- Family Paul Revere Chapter May Meeting.
Chapter 2: Energy Ratings and Economics To be used with the Guide to Building Energy Efficient Homes in Kentucky.
80 years of excellence Commercial Buildings Tax Deduction Ed Gray Director, Energy Infrastructure National Electrical Manufacturers Association.
Chapter 4: Air Leakage Control: Materials and Techniques
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Copyright 2008, International Code Council 2012 IECC ® for SERBCA Based on the 2012 International Energy Conservation Code.
Massachusetts “Stretch” Energy Code Marc Breslow Executive Office of Energy & Environmental Affairs.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
CATEE CONFERENCE SAN ANTONIO, TX December 18, 2013.
Managed by UT-Battelle for the Department of Energy Weatherization Assistant: What’s New in Versions 8.4 and 8.5 Mark Ternes Mike Gettings Oak Ridge National.
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
Arkansas Energy Code 2004 Compliance
1 Connecticut’s New Energy Code Connecticut ASHRAE Tech Session October 13, 2011 Frederick F. Wajcs, Jr. Senior Energy Engineer Connecticut Light and Power.
Original Materials Developed By: Britt/Makela Group, Inc.
IECC, REScheck, and COMcheck Mark Halverson Pacific Northwest National Laboratory PNNL-SA
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
ENERGY CONSERVATION BUILDING CODE – 2006 PRESENTATION BY VP GUPTA PRINCIPAL CHIEF ENGINEER (ELECTRICAL), BSNL CHENNAI.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
Massachusetts New Homes with ENERGY STAR ® The sponsors of the Massachusetts New Homes with ENERGY STAR are Bay State Gas, Berkshire Gas, Cape Light Compact,
Residential Provisions
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Northwest Power and Conservation Council Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction June.
Building Simulation. BMEABMEA uilding odeling nergy nalysis.
IRC CHAPTER 11 AND HERS RESIDENTIAL ENERGY
Lighting systems HVAC systems Lighting Equipment HVAC Equipment Miscellaneous loads Envelope Energy Conservation Measures (ECMs)
The 2012 IECC A Rare Opportunity for Major Energy Savings Add AIA.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Energy Cost Budget Highlights Jason Glazer, PE GARD Analytics Arlington Heights, Illinois Energy Cost.
Week 7 Utility Data Analysis. Essential Elements Identify sources for obtaining utility data: paper form, electronically or from the internet Review utility.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Zone 4 R-38 Ceilings U-0.35 Windows, Doors R-13 Walls R-19 Floors R-10 Foundations.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Stretch Code Informational Session March 16, 2011.
ENERGY SYSTEMS LABORATORY ABOVE CODE ENERGY ENHANCEMENT PROJECT for The City of Arlington ENERGY SYSTEMS LABORATORY Texas Engineering Experiment Station.
Stretch Code Informational Session February 16, 2011.
2015 International Energy Conservation Code
Truss Heel Heights and Energy Code Requirements
2017 Commercial Energy Efficiency Program
2015 Energy Code: Major Changes for Residential Buildings
Energy Code Program Manager – SPEER
BUILDING Codes And Standards
Compliance Software Tool Approval Technical Assistance Manual
Presentation transcript:

What’s new?

…including “fixes” made to the code in the 2012 Supplement August,

New Base Code 2009 International Energy Conservation Code (IECC) Florida specifics are integrated into the document The biggest change is reorganization of the code The energy code will once again become a separate document: the Florida Building Code, Energy Conservation The code will become 5% more stringent than it was in the 2007 code; 20% more stringent than the 2006 IECC The base code is more prescriptive, so the “you gotta’s” likely make up the 5% increase in stringency

NEW CODE FORMAT Chapter 1ADMINISTRATION Chapter 2DEFINITIONS Chapter 3DESIGN CRITERIA (GENERAL) Chapter 4RESIDENTIAL ENERGY EFFICIENCY Chapter 5COMMERCIAL ENERGY EFFICIENCY Chapter 6REFERENCED STANDARDS Appx AJURISDICTIONAL DATA Appx BCRITERIA FOR COMPUTER MODELING Appx CFORMS

Compliance Chapter Format RESIDENTIAL Sections COMMERCIAL Sections 401General 402Building Thermal Envelope 403Systems 404Electrical Power and Lighting Systems 405Simulated Performance Alternative 501General 502Building Envelope Requirements 503Bldg Mechanical Systems 504Service Water Heating 505Electrical Power and Lighting Systems 506Total Building Performance

Compliance Methods The code still has two main compliance methods: PRESCRIPTIVE: Residential section Form 402 Residential will have an alternate Form 402 from a Florida- specific ResCheck Commercial section 502—Form 502 No EZ Com will be available Form 502 is only for shell buildings, renovations, changeouts PERFORMANCE: Residential computer printout—Form 405 Commercial computer printout—Form 506

Computer programs for use by the PERFORMANCE Method Computer programs allowed to be used for code compliance are no longer referenced by the code Programs will be approved separately by the Florida Building Commission. They must utilize the Standard Reference Design (baselines) and other criteria from Normative Appendix B and demonstrate validity by use of criteria in the Energy Simulation Tool Approval Technical Assistance Manual. They must print out in a format familiar to the building departments inspecting for code compliance. Approved programs can be found at the following web site: nergy_Code_Compliance_Software.html nergy_Code_Compliance_Software.html

In the 2012 Supplement The Standard Reference Design criteria for commercial buildings from Chapter 11 of ASHRAE are added to Appendix B, Table B-2.2. Provides transparency so the designer can see what the building is being compared to (plus the.80 multiplier!) Exemptions to code compliance inadvertently omitted from Chapter 1 are added back in by the 2012 Supplement  Buildings designed for purposes other than general space comfort conditioning

Computer programs to demonstrate residential code compliance by the Total UA Alternative This is a PRESCRIPTIVE code compliance method alternative for residential applications (Section ). It allows U-value tradeoffs for the building envelope. All other criteria for compliance by Section 402 must be met. Table was fixed in the 2012 Supplement to change footnote b to the “exterior” of the wall and to change the Mass Wall U-factor allowed to reflect an actual block wall. Programs don’t have to meet criteria in the Energy Simulation Tool Approval Technical Assistance Manual. Approved programs (so far) include REScheck Florida and EnergyGauge USA.

Limited/special use buildings; alternate materials & methods Buildings determined by the code official to have a limited energy use or special use requirement may have code requirements adjusted by the code official where nationally recognized energy analysis procedures are used to demonstrate that the building would use less energy than a code compliant building. Code official may approve alternate materials & methods where a nationally recognized energy analysis procedure is used to demonstrate that a building or component will use less energy than a code compliant building or component. Commission approval is no longer required.

Replacement of HVAC equipment Mix-matched criteria unchanged. Equipment sizing is now required for existing residential buildings (requirement for sizing for existing commercial buildings was deleted in the 2012 Supplement). Existing equipment need not meet minimum code efficiencies; shall be returned to the conditions of its listing. With total replacement of HVAC evaporators and condensing units on residential buildings, all accessible (≥30 inches clearance) joints & seams in the air distribution system shall be inspected and sealed where needed using reinforced mastic or code approved equivalent Signed certification by the contractor attached to air handler Exceptions: 1. Ducts in conditioned space 2. Joints or seams that are already sealed with fabric & mastic 3. If system is tested and repaired as necessary.

Residential: What’s new? Air infiltration requirements are changed Blower door test to demonstrate ≤7 ACH or checklist for inspection Recessed lights shall be IC-rated and labeled to meet ASTM E 283

RESIDENTIAL: What’s new? Section 402: Prescriptive compliance Section 405: Performance compliance Windows: Maximum 20% of conditioned floor area; U-factor ≤0.65; SHGC ≤0.30 Ducts: Must be inside conditioned space & tested to Q n ≤0.03 by a Class 1 BERS Rater or Class A, B or Mechanical contractor HVAC Controls: Programmable thermostat required for forced air furnaces Windows: Maximum weighted average SHGC 0.50 except if 4’ overhang Ducts: No change HVAC Controls: No change

Residential lighting: 50% of lights must be high-efficacy lamps High-efficacy lamps include compact fluorescent lamps, T-8 or smaller diameter linear fluorescent lamps, or lamps with a minimum efficacy of: lumens per watt for lamps over 40 watts, lumens per watt for lamps over 15 watts to 40 watts, and lumens per watt for lamps 15 watts or less Examples: Compact Fluorescent Linear Fluorescent Metal Halide High Pressure Sodium LED Induction

New Residential Swimming Pools Gas pool heaters will have to meet a new national standard of 82% thermal efficiency on April 16, Heated pools shall have a vapor-retardant cover or a liquid cover or some other means to reduce heat loss. Pool filtration pump motors shall: Not be split-phase, shaded-pole or capacitor start-induction Motors with ≥1 hp shall have capability of operating at two or more speeds; low speed no more than ½ the motor’s maximum rotation rate Motor controls shall have capability to operate at ≥2 speeds; default residential filtration speed with higher speed override capability--except can be higher for not to exceed 24 hours Except solar pool heating systems during periods of usable solar heat gain

RESIDENTIAL: What’s not? Florida equipment “Standard Reference Design” (baselines) did NOT go to “same as Proposed Design” as in the IECC. The IECC does not give credit for higher efficiency systems Florida follows federal law, which requires state codes with baselines to have equipment baselines at federal minimums. Florida’s increase in overall stringency comes from a multiplier of 0.80 applied to the entire Standard Reference Design budget…which makes the code 20% more stringent overall than the baseline features. The requirements of Florida’s prescriptive compliance method reflect a building that would minimally comply with Florida’s performance-based code. Credits may be claimed as per previous performance-based code; ceiling fan credit was reinstated by 2012 Supplement.

Residential: HVAC equipment and air distribution Minimum equipment efficiencies and duct sealing requirements are referred to Chapter 5 to avoid duplication. Section 402, the Prescriptive code compliance method, requires ducts to be in conditioned space and tested to be “substantially air tight” (Q n ≤ 0.03). Duct testing by a certified BERS rater, Class A or B Air-conditioning or Mechanical Contractor (changed by law and the 2012 Supplement) A programmable thermostat is required for compliance by Section 402; credit is provided by Section 405. There is NO CHANGE to duct requirements for residential buildings complying by Section 405 R-8 duct insulation appeared to be required by Section but was not specified elsewhere; R-6 was clarified in the 2012 Supplement Credit is given for duct testing to test result level efficiency.

COMMERCIAL BUILDINGS What’s new? HVAC equipment updated to ASHRAE addenda IEERs (Integrated Energy Efficiency Ratio) replace IPLVs for most commercial-sized cooling equipment See footnote “c”: tables are formatted to combine cooling equipment with different heating types into one category. May subtract 0.2 from required EER and IEER where the heating is not electric resistance heat. Equipment is treated as either a simple or complex system. New water chilling package table provides 2 paths for determining compliance, A & B, and a new equation for determining chiller efficiency required (for max. full load and NPLV) where not designed for operation at AHRI 550/590 test conditions

Fan power limitation for supply fans, return/relief fans and fan-powered terminal units associated with systems providing heating or cooling capability, now has two options: Allowable fan system motor nameplate hp Fan system bhp Credit is allowed for Enthalphy Recovery Ventilation (ERVs) Credit is provided for vegetative roofs under certain conditions

What happened with the commercial program? Unintended consequences were corrected. Credit for improved fan power system was inadvertently eliminated at first, but was reinstated with the 2012 Supplement. Scheduling issues with “unmet hours” also were resolved with the 2012 Supplement The code got more stringent by 5 percent Equipment efficiency requirements went up in some cases

Building envelope requirements in Section Florida has not had a prescriptive energy code compliance method since the 2004 Florida Building Code because of the overall increase in code stringency. Apparent R-values for shell buildings are very high (R-40!) Section of the energy code allows shell buildings to comply by either Sec. 502 or Sec. 506, but requires com- pliance by Section 506 be demonstrated later anyway. If complying by Section 506, all assumptions made about features not installed until later that are not on the plans must be listed and appended to the code compliance form.

COMMERCIAL: What’s new, cont. Retail lighting power may now be calculated as follows: Additional Interior Lighting Power Allowance = 1000 watts + (Retail Area 1 x 0.6 W/ft²) + (Retail Area 2 x 0.6 W/ft²) +( Retail Area 3 x 1.4 W/ft²) + (Retail Area 4 x 2.5 W/ft²) Where: Retail Area 1 = The floor area for all products not listed in Retail Areas 2, 3, or 4. Retail Area 2 = The floor area used for the sale of vehicles, sporting goods and small electronics. Retail Area 3 = The floor area used for the sale of furniture, clothing, cosmetics and artwork. Retail Area 4 = The floor area used for the sale of jewelry, crystal and china. Exception: Other merchandise categories are permitted to be included in Retail Areas 2 through 4 above, provided that justification documenting the need for additional lighting power based on visual inspection, contrast, or other critical display is approved by the authority having jurisdiction.

Daylighting control Daylight Zone Control. Daylight zones, as defined by this code, shall be provided with individual controls that control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical fenestration are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e., north, east, south, west). Daylight zones under skylights more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical fenestration. Exception: Daylight spaces enclosed by wall or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting.

COMMERCIAL: What’s new, cont. Exterior lighting is divided into four zones with individual lighting power allowances provided for each type Lighting zone description Zone 1: Developed areas of national parks, state parks, forest land, and rural areas Zone 2: Areas predominately consisting of residential zoning, neighborhood business districts, light industrial with limited nighttime use and residential mixed use areas Zone 3: All other areas Zone 4: High activity commercial districts in major metropolitan areas as designated by the local land use planning authority

COMMERCIAL: What’s not new? Most requirements are the same, just reformatted. Duct insulation criteria are the same as ‘07 code Florida-specific duct construction requirements are combined into a table, Table New criteria added for plastic duct, duct fasteners Duct support criteria moved to the Mechanical code Piping insulation requirements unchanged (they were corrected in the 2012 Supplement) Electrical requirements and motors unchanged

Code support has moved!!! From the Florida Department of Community Affairs (DCA) to the Florida Department of Business and Professional Regulation (DBPR). The Building Code Information System remains at Individual addresses are changed. Example: Ann’s NEW telephone number: (850) Codes & Standards Office: (850)