1 HVAC System Efficiency Upgrade Cost to Consumers RTF Current Estimates Compared to Estimates Provided by Mark Jerome Pacific Air Comfort February 20,

Slides:



Advertisements
Similar presentations
New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Advertisements

1 1 BASICS OF ENERGY MANAGEMENT Section A - Energy Basics.
Planning for Updates and Linkages to EM&V CALMAC February 17, 2004.
GEOTHERMAL AND SOLAR PANEL INSTALLATION BY GRACE BALDWIN.
Policies to Encourage Home Energy Retrofits: Comparing Loans and Subsidies Margaret Walls Resources for the Future 30 th USAEE/IAEE North American Conference,
1 Cost-Effectiveness Screening Issue for RTF August 30, 2007.
RTF Meeting January 23, 2013 Kevin Smit x247 RTF Costs and Benefits Standard Information Workbook A registered professional engineering corporation.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
Energy Efficient Heating and Cooling Systems For Today Geothermal Heating, Cooing And Hot Water Systems.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
Leadership in Environmental Stewardship in a Fiscally Prudent Manner WAUKESHA COUNTY SUSTAINABILITY EFFORTS.
MVP House in Montana Energy Savings and Costs March 2 nd, 2009 Regional Technical Forum 1.
1 NRCan Report Anil Parekh Presented to CHBA TRC March 3, 2010.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Earth’s Changing Environment Lecture 22 Energy Conservation in Heating and Cooling.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
1 Ground Source Heat Pump Rebates 2013 February 13, 2013 Ann Kirkpatrick, Trade Relations Manager.
1 Air Source Heat Pumps Potential Changes in the RTF’s Specifications & Savings Estimates and Their Impact on C&R Discount Program Credits.
DUCT EFFICIENCY AND HEAT PUMP PERFORMANCE Paul Francisco David Baylon Ecotope, Inc.
Northwest Power and Conservation Council Deemed Energy Savings and Cost-Effectiveness of 80-Plus Power Supplies RTF January 2007.
Lighting Savings Calculations for Northwest Energy Star ® Homes David Baylon.
Northwest Power and Conservation Council Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction June.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum August.
Ductless Heat Pumps Determining Cost Savings Example Gary Nordeen Bill Kingrey, P.E. 11/5/08 AFE Webinar.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential LED Recessed Down light Fixtures RTF January 4, 2011.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
Northwest Power and Conservation Council HVAC and DHW System Conversion Cost for Use in Direct Use of Natural Gas Analysis August 16, 2010.
HVAC and DHW System Conversion Cost and Energy Use Assumptions for Direct Use of Natural Gas Analysis September 28, 2010.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
RTF Management Update Jennifer Anziano Regional Technical Forum April 14, 2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
Federal Tax Credits For Energy Efficient Products.
Analysis of Weatherization Measures Options for Savings Methodology and Presentation of Costs from 6 th Plan Regional Technical Forum May 4 th, 2010.
Air Source Heat Pump Specifications Proposed Revisions Regional Technical Forum Subcommittee July 2, 2013.
1 Proposed Revisions to Deemed Savings Input Assumptions for PTCS Duct Sealing and Heat Pump Efficiency Upgrades and Duct Sealing, Commissioning and Controls.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006 Revised August 8, 2006.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
REM as a Compliance Tool Infiltration Trade-off REMRate vs. SEEM February 19th,
Proposed Rooftop HVAC Standardized Field Measurement Protocol and Annual Savings Calculator RTUG REVIEW January 31, 2012.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Northwest Power Planning Council Residential Space Conditioning and Domestic Hot Water Conservation Resource Assessment Overview of Analytical Process.
Implementer’s Group May 2015 Meeting Debrief and Upcoming Meeting Prep May 19, 2015.
Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction May 5, 2009.
1 Proposed Changes to the RTF’s Heat Pump Deemed Savings and Cost- Effectiveness Draft 6th Plan Assumptions April 7, 2009.
PTCS Ducts Inside Single Family New Construction Energy Savings and Cost Regional Technical Forum May 5,
1 Mission Valley Power Energy Efficient Home Program and GSHP Deemed Savings Analysis September 30, 2008.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006 Revised August 8, 2006 Revised Again January 23, 2007.
Air Conditioner Efficiency. Air Conditioner Problem Suppose an older home in San Antonio is equipped with a central air-conditioning unit with SEER rating.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
DHP for New Construction: How to establish the baseline Adam Hadley and Phillip Kelsven RTF Subcommittee December 4, 2015.
Commercial Clothes Washer UES Measure Update Regional Technical Forum April 16, 2013.
A Reliable but Simplified Method for Measuring the Savings from Advanced RTU Control Retrofits February 13, 2013 Presentation to: RTF Commercial Rooftop.
Direct Use of Natural Gas Status of Analysis Staff Analysis Today’s Agenda: Review of Major Analytical Input Assumptions Present Preliminary Results (Not.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Road-Mapping Session BPA Energy Efficiency.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006 Revised August 8, 2006 Revised Again January 23, 2007.
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
R2000 Housing Heating Joe Samson M-G September 27, 2005.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Commercial Refrigerators and Freezers Cost & Cost-Effectiveness RTF Meeting March 2nd, 2010 (continued from Feb 2 nd, 2010 meeting, with more Cost discussion.
1 Potomac Electric Power Company Case 9155 & Delmarva Power & Light Case 9156 EmPOWER MARYLAND DRAFT NON-RESIDENTIAL ENERGY EFFICIENCY AND.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Home Energy Savings Program Wyoming
Presentation transcript:

1 HVAC System Efficiency Upgrade Cost to Consumers RTF Current Estimates Compared to Estimates Provided by Mark Jerome Pacific Air Comfort February 20, 2007 Updated - May 22, 2007 to Include GSHP Cost Estimates

2 Gas Forced Air Furnace System Cost Comparison

3 Gas Forced Air Furnace System Incremental Cost Comparison

4 Air Source Heat Pump System Cost Comparison – HSPF 7.7/SEER 13

5 Air Source Heat Pump System Cost Comparison – HSPF 8.5/SEER 13

6 Air Source Heat Pump System Cost Comparison – Incremental Cost of HSPF 8.5/SEER 13

7 Geothermal Heat Pump Cost and Savings Update – Why Now? Revised federal air source heat pump standards reduced incremental cost and savings from upgrades to Energy Star GSHPs Recent GSHP installed cost data significantly higher than current RTF assumptions Revised estimates of “minimum code” air source heat pumps increase incremental cost difference

8 Geothermal Heat Pump Cost: Sample of OTEC Program Participants UnitCostCOPEERCapacity (Tons) 1$10, $19, $19, $17, $10, $12, Average$14,

9 Geothermal Heat Pump Cost: Sample of OTEC Program Participants UnitCostNotes 1$10,793 Customer did own trenching and backfilling 2$19,412 New furnace and ductwork; 6 trenches 150’ each with header main line) 3$19,162 New construction, includes ductwork of 22 runs and two returns) The ground was very rocky and took more labor for digging. 4$17,000 All done by contractor 5$10,260 Customer did own trenching and backfilling 6$12,500 Customer did own trenching and backfilling Average$14,855 All Systems

10 Geothermal Heat Pump Cost: Source Mark Jerome, Pacific Air Comfort Installed CostLowMidHigh GSHP Cost$7,500$9,000$10,500 Loop$5,000$8,000$12,000 Commissioning & Other$1,000 Baseline Air Source HP$2,400$3,300$4,400 GSHP Incremental Cost$11,100$14,700$19,100

11 Geothermal Heat Pump Cost/Ton Existing RTF vs. Alternative Cost Estimates

12 Recommendations 1.Update GSHP Cost Estimates 2.Use Total Resource Cost (Include customer trenching and backfilling cost) –Best estimate of TRC M. Jerome’s Mid-Point Estimate of Installed Cost 3-Ton Unit x $4900/ton = $14,700 Agrees with OTEC “Contractor Installed” Cost ($4,857/ton) Agrees with “Average Cost” of all OTEC systems ($14,855) 3.Revise Air Source Heat Pump Installed Cost Estimate Use M. Jerome’s Mid-Point Estimate (HSPF 7.7/SEER 13) 3-Ton Unit * $1100/ton = $3,300

13 Impact on GSHP of Recommendation on Cost-effectiveness of GSHP Reduces the number of cost-effective GSHP applications by 94% –67 applications under current incremental cost assumptions –4 applications under revised incremental cost assumptions Issue: Should RTF establish “niche” application screen to preserve GSHP measure as options where it is likely to be cost- effective? –Establish minimum house size for new construction –Establish minimum use “pre-upgrade” for retrofits –Limit use to projected savings cost less than $1.30/kWh first year savings (breakeven point for TRC cost-effectiveness in 2006$)