High Pressure Motor Valve. High Pressure: 1” & 2” Screwed connection rated to 4000 psi standard. Can be rated up to 6000 psi. Motor: One that imparts.

Slides:



Advertisements
Similar presentations
Pilots & Accessories.
Advertisements

Control Valves Control Valves.
Balanced Motor Valves.
Low Pressure Motor Valves. Single Acting Motor Valve Single soft seat Tight shut-off Full line size opening Removable valve seat Optional opening assist.
Valve Globe Gate Diaphragm Through Angle Three Way Multiple Oriffice Knife Linear Motion.
Basic Refrigeration Cycle
Treater Oil & Water Valves
Severe Service Metal Seated Ball Valves
V701 Series Venturi Seat Valve Notes:.
The Swagelok® SK series and AFS Multipurpose Ball Valves
©2008 Armstrong International, Inc. Basic Steam Trap Operation.
Pneumatic Control Valves
COMMERCIAL REFRIGERATION
POWER EQUIPMENT INSTRUCTOR: ROBERT A. MCLAUGHLIN ZAILI THEO ZHAO AUTOMATED CONTROL VALVES & PRESSURE REGULATORS W EEK :29 1.
Process Control Instrumentation II
March 31st and April 1st, 2009Mile High Industrial and Automation Conference Basic Operation and Function of Industrial Regulators.
HVACR312 - Refrigeration Metering Devices.
Section 5: Commercial Refrigeration
VALVES TYPE & FUNCTION VALVES.
Valve Considerations For Feedwater Applications. Presentation Overview Definitions of operating characteristics pertaining to Feedwater control valves.
Mechanical Oil Valves.
Actuators.
Lecture 3 Control valves.
What is going on inside a packed stuffing box?
HYDRAULICS & PNEUMATICS
Air Operated Valve Calibration NMV21
Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.
CONTROL VALVE - THEORY & SIZING
Asahi/America Swing Check Valves
Hydronic Balancing „Cocon Q “ Pressure independent dynamic control valve.
Instrument Training Material
Asahi/America Thermoplastic Check Valves Ball Check Valves ½” - 4”PVC, CPVC, PP, PVDF Uniseat/ Seal.
HVAC523 Circulator Pumps.
Air Conditioning Metering Devices.
Temperature Control Loop
CONTROL VALVES By M.Freethan M
ACHIEVING REDUCED FLARING THROUGH CONTROL VALVES
Clark Reliance Corporation Strongsville, OH. Fuel Gas Treatment.
Valves In Industry (Part 2)
Valves In Industry (Part 2).
Piping and Valves Unit 8. Today’s Agenda Purpose of piping and valves Material of construction and service Pipe fittings Piping and valve connections.
Warlocks 8/5/05 TMU Pneumatics on Robots u Simplified model Compressed Air Tank Geek Safety Glasses 60 lbs Pneumatic Cylinder Whoa! That’s a lot of force.
XAS 375 CD6 Compressors Committed to sustainable productivity
Hydraulic Flow Control MECH1300 Topics Flow Control Valve Types Flow Coefficient Circuits Cushioned Cylinders Flow Dividers Flow Control Valve Specifications.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Floatless Liquid Level Controllers. No float! Large connection opening is not necessary. No worry about inside clearance.
Valves In Industry (Part 2). Control Valves The most common final control elements. Function- control system by adjusting the flows that affect the controlled.
Small Engines Ag  Identify basic terms and definitions associated with carburetion  List and identify individual engine parts related to carburetion.
Session 6 - Agenda BREAK Activity Est. Time 1. Agenda
Valves.
Control Valves. Section E1 For discharge of liquid or gas from vessels. For Back Pressure or Pressure Reducing applications with pressure pilots. Section.
TODAY’S TOPIC CONTROL VALVE controller Inst Air. What is control valve? Control valves are such type of valves which are controlled remotely to maintain.
Introduction to Final Control Elements
Actuator Edi Leksono Department of Engineering Physics
Petroleum Instrumentation NGT 160
Components Valves.
Product Profile, Features and Options
GOVERNMENT ENGINEERING COLLEGE, BHARUCH.
© Copyright, HQT-SV Control System
VALVES CONTREN Series #
Valves.
SB Packing Automatic Downpuller Power Unit
منطقه چهار عمليات انتقال گاز عمليات بهره برداري خطوط لوله گاز
Asahi/America Globe Control Valves
Asahi/America Gate Valves
VALVES TRAINING CENTREThursday, February 21, 2019.
Flow Control Valves & Pressure Relief valves
Hydraulic Flow Control • Metering Fluid Flow
Presentation transcript:

High Pressure Motor Valve

High Pressure: 1” & 2” Screwed connection rated to 4000 psi standard. Can be rated up to 6000 psi. Motor: One that imparts motion.

High Pressure Motor Valve FIELD REVERSIBLE TOPWORKS OPEN YOKE STUFFING BOX No adjustment No lubrication Teflon – low friction POSITION INDICATOR BALL AND CONE SEAT

High Pressure Motor Valve

Field Reversible Topworks

High Pressure Motor Valve

High Pressure Motor Valves

65 Topworks 65 sq. in. diaphragm P. O. service Extends 1” HPMV with ½” inner valve to 4000# W.P. Extends SMS valve to 4000# W.P. Available for 1”, 2” and non-freeze HPMV Wide spring adjustment range

Manual Valve Positioner Used as a limit for valve stem travel Used to manually open the valve on unit start-up Each revolution of the handle moves the stem 1/16” ¾” max. stem travel

Pneumatic Valve Positioner Maintains stem position through changes in force on stem Provides repeatable stem placement

Soft Seat 15/16” port in 1” valve 1-1/2” port in 2” valve Maximum pressure drop: 300 psi On / Off service only

Improving Service of HPMV’s Size Valve Properly. Valve should operate between 50% and 80% of its capacity Use quick opening trim in erosive service. Use Carbide or Zirconia trim in highly erosive service. Use Equal Percentage trim for controlling pressure or flow rate.

SNAP NOMINAL =%AGE Trim Characteristics

Ceramic Trim Carbide Zirconia

Maximum Pressure Drop 1” Motor Valves 2” Motor Valves I.V. Throttle Relief 1/2” 3/8” ” 3/4”

Piston Balanced High Pressure Motor Valve Full line size port Balanced plug Soft seat with metal to metal backup Field reversible topworks Equal Percentage Trim Bubble tight shut-off Sizes available: 2”, 3,” 4” & 6”

Maximum Working Pressure: Connection W. P. 2” Screwed 4000 psi. 2” Flanged ANSI 1500 (3705 psi*) 3” Flanged ANSI 600 (1480 psi*) 4” Flanged ANSI 600 (1480 psi*) 6” Flanged ANSI 600 (1480 psi*) * For working pressure vs. working temperature of these flanges see ANSI B16.2. Piston Balanced High Pressure Motor Valve

1” Non-Freeze Dump Valve Inner valve located to utilize vessel heat to prevent freezing 1” NPT inlet & outlet 2” NPT vessel mounting Up to 4000 psi W.P. 1/8” –1/2” inner valves available

Non-Freeze Dump Valve Vertical Separator

Horizontal Separator “Stinger” Non-Freeze Dump Valve

Metering Valve Calibrated in 1/64” equivalent orifice diameter Available in 1”& 2” standard HPMV Also available in 2” & 3” piston balanced HPMV

Piston Balanced Metering Valve

Optional Vee Packing Glass filled Teflon Virgin Teflon Carbon filled Teflon Glass filled Teflon Max. Temperature: 500 o F