CT Instrumentation and X-ray system

Slides:



Advertisements
Similar presentations
Advanced Biomedical Imaging Lecture 3
Advertisements

COMPUTED TOMOGRAPHY INSTRUMENTATION AND OPERATION
Line focus principle Heal effect Ratings Tube failure
COMPUTED TOMOGRAPHY INSTRUMENTATION AND OPERATION
Formation Characteristics
{ Projection Radiography Chapter 5 (in more detail)
Historical Development
Chapter 17 The Grid So far we have discussed how kVp, patient size and collimation impact scatter radiation. As the part size and kVp increase, scatter.
X-ray tube and detection of X-rays Lecture 5. Reminder: The rough schematics of an X-ray tube filament cathod target anode photon flux e-e- electron kinetic.
Dental X-ray Machine 118 Radiology.
FRCR: Physics Lectures Diagnostic Radiology
MAMMO QC – covered in week 8
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Analyzing the Image Density. Density Overall blackening of the image.
354 Chapt. 6 X-ray Tube TWO Primary components – cathode and anode Tube must be supported: Ceiling/floor mounted/C-arm, etc. – SID’s – Detents (center.
Computed Tomography II
MULTISLICE CT.
Medical Imaging X-Rays I.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Instrumentation Part 1.
Computed Tomography RAD309
Seeram Chapter 5: Data Acquisition in CT
Lecture 4 Beam restricting Devices, their Use and Maintenance
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Factors affecting the X-Ray output
X-Ray Production & Emission
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Production Chapter 8.
X-Ray Production & Emission
Conventional and Computed Tomography
Reference Reading Chapter 2: pp  X-rays are produced within the dental x-ray machine  The x-ray machine can be divided into 3 study areas.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Basic principles Geometry and historical development
Computed Tomography by Ms. Nouf Alzahrani Dr. Saddiq Jastniah
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
ADC PRE-PATIENT COLLIMATION POST-PATIENT COLLIMATION.
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Alhanouf Alshedi CT Physics and Instrumentation RAD
Quality Control.
Ch. 2 – Anatomy of the X-ray Machine
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
CT Physics Lecture 3.
Resident Physics Lectures
Computed Tomography Q & A
PRINCIPLES OF CT Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture principles of CT.
Chapter 2 The X-ray Beam.
Factors affecting CT image RAD
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Emission Chapter 9.
Module C Computed Tomography Physics, Instrumentation, and Imaging.
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
Module D Computed Tomography Physics, Instrumentation, and Imaging.
Part No...., Module No....Lesson No
Part No...., Module No....Lesson No
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
X-ray tube.
An early x-ray by Wilhem Rontgen
Treatment Machines for External Beam Radiotherapy
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
CT Scanner Detection system. 2 CT Scanner n Generator s High frequency, kW n X-ray tube s Rotating anode, high thermal capacity: 3-7 MHU s Dual.
RAD 253 Chapter 7 The X-ray Tube Two primary components: cathode and anode.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
CT Multi-Slice CT.
Computed Tomography Data Acquisition
Part No...., Module No....Lesson No
X-Radiation.
Exposure Factors Chapter 4
Resident Physics Lectures
Resident Physics Lectures (Year 1)
Resident Physics Lectures (Year 1)
Generation of X-rays Q&A
Presentation transcript:

CT Instrumentation and X-ray system 2ed Lecture Alhanouf Alshedi Email: aalshedi@ksu.edu.sa

Scanner GANTRY PATIENT COUCH

Gantry : Is a mounted framework that surrounds the patient that houses these components: X-ray tube Generator Collimators Detectors Filters

X-ray tube: Uses high frequency generator. To maximize x-ray tube heat capacity: Uses rotating anode x-ray tube. small target angle. large anode diameter focal spot size appropriate to geometry Some use a metal envelope, which have larger anode disks. This allows the tech. To use higher tube current and heat capacity is also increased. Cathode consists of one or multiple filaments.

mA – tube current: The number of electrons flowing from cathode to anode. kVp: Potential difference between cathode and anode (Volts) kilo means 1,000 x. S –time of exposure: mAs tube current for certain length of time.

Generator High –frequency generator which is : Small Compact More efficient than conventional generators. Is located inside the gantry. Provides power ranging 20-100 kilowatts

Filters: They serve a dual purpose: Filtration removes long-wavelength x-rays as do not play a role in C.T image formation and add to patient dose. Filtration shapes the energy distribution across the beam to produce a uniform beam.

Collimation: It protects the pt by restricting the beam to area of interest. Shape the beam and removes scatter radiation which improves axial resolution. - Adjustable pre-patient (between tube & patient) and pre-detector collimators: (between patient and detector) - Must be perfectly aligned to optimise imaging process.

Pre-Collimation Constrains size of beam. Pre-collimator Tube Detector Constrains size of beam. Reduces amount of scatter produced. Designed to minimize beam divergence. Often consists of several stages or sets of jaws.

Post-Collimation Helps define slice (beam) thickness. Reduces scatter radiation reaching detector Tube Detector Post-collimator

GANTRY CHARACTERISTICS Has two important features: 1)APERTURE: It is the opening in which the pt moves through during scanning. Most of the scanners have 70cm aperture, which facilitates pt positioning and provides access to pt in emergency situations. 2)TILTING RANGE: To accommodate all patients and different clinical exams. Tilting range of most scanners +30 to -30 degrees.

COORDINATE SYSTEM X

Y

Z

ISOCENTRE

PATIENT COUCH Should be strong and rigid to support weight . Usually made of carbon fibers due to their low absorption. 450 lbs (204 kg) distributed weight limit. Provides vertical and horizontal movement. Scannable range: coverage from head to thigh (162cm)

Any Question? Thank You