R&D program in JFY2002 for JLC vertex detector N.Tamura ; Niigata University Y.Sugimoto, A.Miyamoto ; KEK T. Aso ; Toyama National College of Maritime.

Slides:



Advertisements
Similar presentations
CO2 cooling for FPCCD Vertex Detector Yasuhiro Sugimoto KEK 1.
Advertisements

Background effect to Vertex Detector and Impact parameter resolution T. Fujikawa(Tohoku Univ.) Feb LC Detector Meeting.
Development of an Active Pixel Sensor Vertex Detector H. Matis, F. Bieser, G. Rai, F. Retiere, S. Wurzel, H. Wieman, E. Yamamato, LBNL S. Kleinfelder,
March, 11, 2006 LCWS06, Bangalore, India Very Forward Calorimeters readout and machine interface Wojciech Wierba Institute of Nuclear Physics Polish Academy.
CHARGE COUPLING TRUE CDS PIXEL PROCESSING True CDS CMOS pixel noise data 2.8 e- CMOS photon transfer.
Jaap Velthuis, University of Bristol SPiDeR SPiDeR (Silicon Pixel Detector Research) at EUDET Telescope Sensor overview with lab results –TPAC –FORTIS.
Paul Sellin, Radiation Imaging Group Charge Drift in partially-depleted epitaxial GaAs detectors P.J. Sellin, H. El-Abbassi, S. Rath Department of Physics.
PHENIX Vertex Tracker Atsushi Taketani for PHENIX collaboration RIKEN Nishina Center RIKEN Brookhaven Research Center 1.Over view of Vertex detector 2.Physics.
Track Timing at e + e - Linear Collider with the Silicon Drift Detector Main Tracker R. Bellwied, D. Cinabro, V. L. Rykov Wayne State University Detroit,
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Jianchun Wang Marina Artuso Syracuse University 11/06/00 MC Simulation of Silicon Pixel Detector.
A new idea of the vertex detector for ILC Y. Sugimoto Nov
R&D Status of FPCCD Vertex Detector Dec.1, 2006 Yasuhiro Sugimoto KEK.
Development of Readout ASIC for FPCCD Vertex Detector 01 October 2009 Kennosuke.Itagaki Tohoku University.
Study of FPCCD Vertex Detector 12 Jul. th ACFA WS Y. Sugimoto KEK.
Fine Pixel CCD Option for the ILC Vertex Detector
Development of CCDs and Relevant Electronics for the X-ray CCD camera of the MAXI Experiment onboard the International Space Station Osaka University E.
Paul Sellin, Radiation Imaging Group Charge Drift in partially-depleted epitaxial GaAs detectors P.J. Sellin, H. El-Abbassi, S. Rath Department of Physics.
07 October 2004 Hayet KEBBATI -1- Data Flow Reduction and Signal Sparsification in MAPS Hayet KEBBATI (GSI/IReS)
Jim Brau, Amsterdam, April 2, Nikolai Sinev and Jim Brau University of Oregon April 2, 2003 Radiation Damage Studies of Vertex Detector CCDs First.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
R&D status of FPCCD VTX and its cooling system Yasuhiro Sugimoto for FPCCD VTX group 1.
Silicon Sensors for Collider Physics from Physics Requirements to Vertex Tracking Detectors Marco Battaglia Lawrence Berkeley National Laboratory, University.
1 R&D Status and plan for FPCCD VTX Yasuhiro Sugimoto
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Detector Studies in Asia T.Tauchi, Prague Ecfa/Desy Workshop Session on Detector Plenary Reports Sunday, 17 November 2002.
FPCCD VTX Overview Yasuhiro Sugimoto KEK Tokubetsu-Suisin annual meeting 11.
Vertex Detector for GLD 3 Mar Y. Sugimoto KEK.
Impact parameter resolution study for ILC detector Tomoaki Fujikawa (Tohoku university) ACFA Workshop in Taipei Nov
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
1 Engineering issues for FPCCD VTX Detector Y. Sugimoto KEK July 24, 2007.
Status report on the Asian Solid State Tracking R&D March 31, 2003 M. Iwasaki University of Tokyo.
Fine Pixel CCD for ILC Vertex Detector ‘08 7/31 Y. Takubo (Tohoku U.) for ILC-FPCCD vertex group ILC vertex detector Fine Pixel CCD (FPCCD) Test-sample.
Development of CCDs for the SXI We have developed 2 different types of CCDs for the SXI in parallel.. *Advantage =>They are successfully employed for current.
2006 Work Plan Y. Sugimoto 25-Apr Study Items Basic study of fully depleted CCD Simulation studies for FPCCD VTX Radiation damage Thin wafer and.
JLC CCD Vertex Detector R&D Y. Sugimoto KEK
FPCCD VTX Overview Yasuhiro Sugimoto KEK Tokubetsu-Suisin annual meeting 11.
LCWS2004 Paris 1 Beam background study for GLC Tsukasa Aso, Toyama College of Maritime Technology and GLC Vertex Group H.Aihara, K.Tanabe, Tokyo Univ.
FPCCD option Yasuhiro Sugimoto 2012/5/24 ILD 1.
FPCCD Vertex detector 22 Dec Y. Sugimoto KEK.
Technology Overview or Challenges of Future High Energy Particle Detection Tomasz Hemperek
LC Tracking Review at Amsterdam Overview of Asian Tracking R&D Vertex Detector Silicon µ-Strip Intermediate Tracker Central Tracker - Jet Chamber.
Silicon Detector Tracking ALCPG Workshop Cornell July 15, 2003 John Jaros.
FPCCD VTX Overview Yasuhiro Sugimoto KEK Tokubetsu-Suisin annual meeting 11.
Impact parameter resolutions for ILC detector Tomoaki Fujikawa (Tohoku university) ACFA Workshop in Taipei Nov
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
1 FPCCD VTX Work Plan Y. Sugimoto 2010/1/22. 2 FPCCD: Features and R&D issues (1/2) Small pixel size (~5  m) –Sensor development Small size chip; ~6mm.
R&D Plan in FY2003 Vertex Detector Subgroup Y. Sugimoto 11 Apr
1 Performance of a CCD tracker at room temperature T. Tsukamoto (Saga Univ.) T. Kuniya, H. Watanabe (Saga Univ.); A. Miyamoto, Y. Sugimoto (KEK); S. Takahashi,
FPCCD VTX Work Plan Y. Sugimoto 2010/1/22. FPCCD: Features and R&D issues (1/2) Small pixel size (~5  m) –Sensor development Small size; ~6mm x 6mm Full.
TRACKING AND VERTEXING SUMMARY Suyong Choi Korea University.
Vertex detector R&D Work Plan in /3/11 Y. Sugimoto for KEK-Tohoku-TohokuGakuin-Niigata- ToyamaCMT Collaboration.
Beam Profile Monitor for Spot-Scanning System Yoshimasa YUASA.
CMOS Pixels Sensor Simulation Preliminary Results and Plans M. Battaglia UC Berkeley and LBNL Thanks to A. Raspereza, D. Contarato, F. Gaede, A. Besson,
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
FP-CCD GLD VERTEX GROUP Presenting by Tadashi Nagamine Tohoku University ILC VTX Ringberg Castle, May 2006.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
R&D status of CCD based vertex detector for JLC
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
Lars Reuen, 7th Conference on Position Sensitive Devices, Liverpool
Detector Studies in Asia
FPCCD Vertex Detector for ILC
Yasuhiro Sugimoto KEK 17 R&D status of FPCCD VTX Yasuhiro Sugimoto KEK 17
CCD based Vertex Detector for GLC
FPCCD Vertex Detector for ILC
Backgrounds using v7 Mask in 9 Si Layers at a Muon Higgs Factory
Status of CCD Vertex Detector R&D for GLC
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

R&D program in JFY2002 for JLC vertex detector N.Tamura ; Niigata University Y.Sugimoto, A.Miyamoto ; KEK T. Aso ; Toyama National College of Maritime Technology K.Abe ; Tohoku Gakuin Univ. G.Iwai, K.Fujiwara, H.Takayama ; Niigata University

Contents I) Design concepts and Requirements – Accelerator Design – VTX detector design – IR design and backgrounds II) Present results and Activities – Radiation hardness – Spatial resolution – Fast readout electronics Summary

Accelerator Design 6mrad crab crossing Beam time Structure Bunch-train Structure Train = One pulse192 bunches 1.4ns N~1E+10 particles 1/150Hz=6.7ms Beam profile at IP 243nm 3.0nm dz=110um I )

VTX Design VTX – Precise Secondary vertex reconstruction Reconstruct decay vertices of B and D meson decays with excellent b/c jet separation – Improvement of momentum resolution Requirements – Unambiguous 2D reconstruction at high hit density Pixel devices Expected occupancy in a 20  m x 5cm s trip detector ~ 100% !, for hit background rate of about 1hit/mm 2 /train. – Less materials (Especially for low momentum tracks) Thin devices Operation at room temperature ~ 0 C -> Simple structure/Easy operation -> Less thermal distortion of wafers o

Room temperature operation CCDs – Features Thin/Low-density material Low power consumption But Needs cooling ? – w/o Cooling system Avoid multiple scattering by cooling system Avoid thermal distortion of sensors ( fabrication – operation temperature discrepancy) Desirable to operate in room temperature ~ 0 C ) Back-illumination CCD : HPK S7170 Thickness ~20  m CCD Flatness o

VTX detector design Baseline design – |cos | < 0.90 – Pixel size 25 um – 1.25cm x 5cm x330um – 4Layers with 10deg tilt ( r=24,36,48,60 mm) ( Ladder 16/24/32/40) (Sensor 2/3/4/5) – Intrinsic resolution 4  m (Just for a Simulation input )

IR Design and Background Model d) 3T with SC-QC1 QC1 : Super Conducting magnet L* = 4.3 m To reduce back scattering background produced by the interaction at QC1 R=8~16.5cm

Background estimation Beam-Beam Interaction – e + e - pair production – Beamstrahlung Secondary produced backgrounds R (mm) TRC(X) 3T * Preliminary R (mm) JLC-A ** JLC- Y** Model b) VTX VTX VTX VTX *Geant4 ( SR/PhotoNuclear ) Include solenoid ( uniform 3T ) +QC1 ( Ideal gradient ) Electron backgrounds ( /mm 2 /train) **Geant3 95bunches Low Lum. Similar to TRC(X) NLC - JLC Neutrons Previous Study 1E+9/cm 2 /Yr (Beamstrahlung) 1Yr operation e + e - pair ~1hit/mm 2 /train 1.5E+11/cm 2 /Yr

Present results and Activities Radiation hardness Spatial resolution Fast readout electronics II)

Radiation hardness HPK10 notch EEV TypeS5466CCD02-06 Pixel size [  m] 2422 R/O clock2-phase3-pahse Epitaxial layer[  m] 1020 Notchnone 3m3m MPP Operation Inverted by holes Si0 2 – Si Interface Small packet Notch CCD 2-Phase CCD 3-Phase CCD Low density

CCD Structure [cont’d] Result > 1.5E+11e/cm 2 JLC: 1.5E+11/cm 2 Result > 1.5E+10 n/cm 2 JLC: 1E+9/cm 2 /Yr (Preliminary) Radiation hardness V ee ( V ) Dark current (electrons/pix) Electrons from 90 SrNeutrons from 252 Cf HPK10

Radiation hardness [cont’d] MethodsVCTI improvement 3-phase to 2-phase ~2.5 times Std to notch structure ~3 or 4 times CTI properties 3Phase 2Phase Std CTI Notch VCTI ( Irradiation ) CTI ( Irradiation ) Electron Neutron HPK10 CTI~N t /N s Concentration N t : Defect N s : Signal

Radiation test -1- Our tests showed “Lifetime of CCD > 1Year ! Why additional test of radiation damage, then ? Non-Ionizing Energy Loss Radiation damage is thought to be proportional to NIEL The radiation damage at JLC estimated to be 10 times bigger than our study using 90 Sr. Radiation damage by high energy (>10MeV) electrons should be studied.

Radiation test -1- [cont’d] Non-Ionizing Energy Loss Radiation damage by high energy (>10MeV) electrons should be studied.

Radiation test (First trial 2002/12/9) Experimental setup Electron Beam 150 MeV Pt 0.1X 0 0.5X 0 Bending Magnet Choice of Settings 1)Primary Beam Energy 150MeV electrons 2)Target radiation length 0.1/0.5 X 0 3)B field High/Low Tesla mode Tohoku-Univ. Lab. of Nuclear Science

Radiation test [cont’d] Plan “Trial Run” -> Real Run in May?, Study of CsI(pure) calorimeter 2. Energy of electrons On target ; 150 MeV On CCD ; 100 MeV Irradiation: 5x10 10 /cm 2 Dosimetry; RadFET

Radiation test [cont’d] Energy distribution of the scattered electrons Incident electrons: 125 MeV/c

Radiation test [cont’d] 3. Cryogenic measuring system for CCD - almost same as the one which Stefanov-san used in Japan Cryostat Temperature Controller CCD Board inside the cryostat

Spatial resolution -Test beam- S/N > Dark current is suppressed by the successful Operation of Inverted mode. Noises in a pixel (R/O cycle ~ 3sec. ) HPK10(23e)/ HPK50(58e) / EEV(37e) HPK50 : HPK with epitaxial layer of 50  m 4-Layers CCD Tracker

Spatial resolution Temp.( C ) MethodHPK10HPK50EEV -15 CAC RLM CAC RLM RLM : RLM function AC : Analog centered Pmax P R = Pixel A Pixel B Signal of Pixel A Signal of Pixel B o

Spatial resolution [cont’d] Intrinsic Resolution Is better than 3  m. Intrinsic Resolution Is better than 3  m. Thermal diffusion of signal charge improves resolution.

Comparison with simulation - by T. Aso Energy deposit(keV) Thickness of active layer(  m) Geant4:Energy Deposit 2GeV,π ‐ HPK keV 7×7cls HPK10 2.2keV 2×2cls Energy Deposit in Silicon Estimated Active layer 11  m for HPK10 51  m for HPK50 ActiveLayer 51.1  m 11.0  m

HPK10 HPK50 Charge sharing simulation - by T. Aso +: d/A=50% × : d/A=30% *: d/A=20% △: d/A=10% □ : d/A=5% Depletion (d) Field Free (f) Active(A=d+f) XX Log(R)  d ~ sqrt(2Dt ) f ~ G.R.Hopkinson NIM A216(1983)432 Energy(keV) N×N Clustering HPK50 HPK10 Open : Exp Close : Sim Drift coff. *Drift Time

Electronics fabrication Readout operation – All pixels must be readout every train crossing interval of 6.7 ms, in the real experiment at JLC. – 10MHz readout can transfer about 250x250pix in the interval. 5cm 1.25cm 250x250pix/chip 16chips/sensor Total 424 sensors 6784 chips needed.

Fast R/O System -1- Features Fast Not expensive Low power Flexible design Optical link LVDS link 1st 2ndFinal

Fast R/O System -2- Evaluation board of ADC – CCD Signal processor chip for Digital Camera 9x9mm 2 chip size ~ $6/chip – AD9844A(Analog Devices Co.) 12bit 20MSPS ADC 20MSPS Correlated Double Sampler 6bit variable CDS Gain Amp. Low power consumption(65mW/2.7V) SHP SHD FADC

Fast R/O System -3- LVDS Inputs for clocks etc XC2V404CS144C(FPGA) AD9844A[FADC] Backside Interface to Digital board (12 bit DBUS] Linearity was confirmed. LSB resolution 0.2mV. Dynamic range 0~800mV

Summary Design and status of JLC VTX detector is presented. Goal --- CCD operation at room temperature Radiation hardness : No problem, so far. –But, further investigation is necessary. Electrons => Higher energy must be confirmed experimentally. ( Additional experiments are going. ) Neutrons => Yield of neutron is ambiguous ( beam dump ) ( Reliable simulation with precise geometry, JUPITER) Spatial resolution : < 3  m at -15 C. –More investigation of charge sharing property improve resolution? ( Laser scanner test at Niigata Univ. with 2x2  m spot.) Readout Electronics: Evaluating –Study the effect of Fast readout for irradiated samples Evaluation of thinned device –Partially thinned CCD..(Distortion measurement system: ready) o

CCM CCD (1) CCM (Charge carrier multiplier) – Multiply generated charge using Impact ionization Multiplying generated charge directly in the charge domain before conversion into a voltage High-field region between the two neighboring gates Gained energy is dissipated through Impact Ionization [II] Small variance in the II

CCM CCD(2) Difficult to reduce the noise floor of existing charge detection amplifiers particularly at high clocking freq.

CCM CCD(3) –IMPACTRON- IMPACTRON – Texas Instruments – TC253SPD – 658(H)x496(V)A pix. In Image Sensing Area – 7.4  m Square Pixels – Charge multiplication gain 1~30 – Charge conversion gain w/o CCM 10  V/e – Epitaxtial Layer depth? CCM (400pix) Charge Multiplication!!!

CCM CCD (4) –IMPACTRON- Gamma ray spectrum 55 Fe 0 o C Driver for Impactron is now being developed. ↓ Will be compared with HPK S5466