Detector Studies in Asia T.Tauchi, Prague Ecfa/Desy Workshop Session on Detector Plenary Reports Sunday, 17 November 2002.

Similar presentations


Presentation on theme: "Detector Studies in Asia T.Tauchi, Prague Ecfa/Desy Workshop Session on Detector Plenary Reports Sunday, 17 November 2002."— Presentation transcript:

1 Detector Studies in Asia T.Tauchi, Prague Ecfa/Desy Workshop Session on Detector Plenary Reports Sunday, 17 November 2002

2 Configuration of the JLC detector

3 Interaction Region and fast feedback system

4 VTX detector design Baseline design –|cos | < 0.90 –Pixel size 25  m –1.25cm x 5cm x 330  m –4Layers with 10 deg tilt ( r=24,36,48,60 mm) ( Ladder 16/24/32/40) (Sensor 2/3/4/5) –Intrinsic resolution 4  m (Just for a simulation input ) 18 24 60 N.Tamura, G.Iwai, K.Fujiwara, H.Takayama; Niigata University Y.Sugimoto, A.Miyamoto ; KEK T. Aso ; Toyama National College of Maritime Technology K.Abe ; Tohoku Gakuin Univ.

5 VTX/CCD status and future plans Goal --- CCD operation at room temperature Radiation hardness : No problem, so far. –But, further investigation is necessary. Electrons => Higher energy must be studied experimentally. ( Experiment will be conducted in this December, E e =100MeV. ) Neutrons => Yield of neutron is ambiguous ( beam dump ) ( Reliable simulation with precise geometry, JUPITER) Spatial resolution : < 3  m at -15 o C. –More investigation of charge sharing property improve resolution? ( Laser scanner test at Niigata Univ. with 2x2  m 2 spot.) Readout electronics: Evaluating –Study the effect of fast readout(20MHz) for irradiated samples Evaluation of thinned device –Partially thinned CCD (Shoji-structure).. N.Tamura, Japan-UK meeting, Nov.2002

6 H. Park, Y.J. Kim, D.H. Shim (CHEP, Kyungpook National Univ.) J.M. Yang, I.H. Park, M.Y. Kim, N.H. Park (Ewha Womans Univ.) J.S. Kang, B.Y. Han, G.B. Yu, H.C. Ha (Korea Univ.) 5 layers at r=9 to 37 cm angular coverage |cos  |<0.9 spatial resolution = 40  m thickness of a layer: 0.6% radiation length without background hits with background hits Efficiency Purity Efficiency Purity No IMT 71.6% 72.5% 71.1% 73.3% With IMT 91.7% 94.4% 90.2% 94.1% For e + e - -> hZ at E cm =300GeV Intermediate Tracker Linking performance of VTX to CDC

7 Central Tracker (CDC) Jet type chamber with long wires (3.1(4.6)m) at B=3 (2)T Momentum resolution:  (1/p t )=3 (1) x 10 -4 /(GeV/c)  z (stereo wires)=1mm,  2track (r  )=2mm,  t =2nsec AVU AVU AVU A KEK, Kinki University, Mindanao State University, Tokyo University of Agriculture & Technology, University of Tsukuba

8 CDC Performances 1 2 3 4 5 mm 1 0.8 0.6 0.4 0.2 0 2 track separation efficiencySpatial resolution Momentum resolution CDC:  Pt /P t =3 x 10 -4 P t (GeV/c) CDC+VTX:  Pt /P t =0.9 x 10 -4 P t (GeV/c)

9 Calorimeter KEK, Kobe, Konan, Niigata, Shinshu and Tsukuba Tile/Fiber Sampling Calorimeter Hardware Compensation Design Flexibility Reasonable cost Well-established thechnology Sufficient granularity for EMCAL ? Scintillator tiles of 5 x 5

10 CAL: Basic Parameters

11 R & D on EMCAL and SHmax EMCAL : Scint. tile of 4cm x 4cm x 1mm t (4cm is limited by fiber curvature) Scint.strip of 1cm x 20cm x 2mm t fine granularity crossed-strip layout like Shmax needs multi-channel photo detectors ghost-rejection capability (full simulation ) SHmax: Scint.strip of 1cm x 20cm x 1cm t WLS fiber+multi-channel photon detector high-gain APD attached directly at the end of Scint. strip Scint. Tile with WLS fiber Scint. Strip with WLS fiber

12 Beam Tests of EMCAL EMCAL 1) Tile of 4cm x 4cm (7.1X o ) 2) Strip Arrays (x,y) of1cm-width Sub-system R&D a) SHmax:direct-attached APD and WLS-readout. b) Super-multi-channel photo -detectors. Present status and future plans 1st exp. just finished on Nov.14 for 1(partial), 2, and a. 2nd exp in November 2003 with 1(full) and b. Y. Fujii for ECFA-DESY at Prague, 2002-Nov-17 Setup of beam test at KEK-  2

13 SHmax (conventional & direct-APD)

14 JSF, A.Miyamoto

15 JSF interactive, A.Miyamoto

16 R  view of VTX CDC 10 layers 36~108cells / layer 5 wires / layer r wire =15  m Event display of e + e - → Z 0 h E = 350GeV T.Aso JUPITER figures

17 Simulation of Beam Delivery System Geometry codes are generated from a SAD file for FFIR optics Particle transportation from the entrance of FF to IP have been confirmed using Geant4 University of Tokyo

18 Support tube R&D H. Yamaoka, 5th ACFA-LC workshop July 10 - 12, 2002

19 Support tube R&D status

20 H. Yamaoka, 5th ACFA-LC workshop July 10 - 12, 2002 Support tube R&D : Test conf. 4 Conf.3 Conf.4

21 Near Future Plans VTX:Radiation (bulk damage) test by 100MeV e’s fast electronics (20MHz) IMT: prototype manufacturing and test CDC: Investigation of wire creeping evaluation of performance by full simulation CAL: EM-CAL(4cm tile & 1cm strip) beam test SHMAX(1cm x 20cm x 1cm t / fiber) beam test granularity and energy resolution studies IR:Optimization of L* ( 3 ~4.3m) and BDS Background study with a fast feedback system prototype study on the support tube (nm stability) Software: JSF development (C++ language) ( JUPITER for full simulation based on GEANT4) Comprehensive evaluation of detector performance “Roadmap”Symposium will be held on 15 February,2003.